POE SWITCH WITH BUFFERED POWER SUPPLY IPUPS-9-11-F 9-PORT ATTE


MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-595 UNI-T

232.92 EUR
232.92 EUR

570.16 EUR
570.16 EUR

LAN ports:  
  • 1 x RJ45 10/100 Base-T - Uplink,
  • 9 x RJ45 10/100 Base-T + PoE (802.3af/at) / Passive PoE  
  • ...  
    Management:    ...  
    Resistance measurement:  ...  
  • Test voltage 250 V : 0.05 MΩ ... 250 MΩ
  • Test voltage 500 V : 0.05 MΩ ... 500 MΩ
  • Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ  
  • LED diodes:  AC, DC, CHARGING (battery charging), PoE  ...  
    Measuring accuracy:  ...  0.05 MΩ ... 1000 MΩ ± (5% + 5)   
    Open circuit voltage:  ...  Test voltage ± 10 %  
    Transmission speed:  
  • 10 / 100 Mbps : 1 x Port Uplink,
  • 10 / 100 Mbps : 9 x Port LAN & PoE  
  • ...  
    Test current:  ...  0.9 mA ... 1.1 mA  
    Short-circuit current:  ...  < 1.8 mA  
    AC voltage measurement:  ...  0 V ... 440 V ± (2% + 3)  @ 1 V  
    Maximal output power:  
  • 40 W @ Passive PoE - LAN1 ... LAN4 ports,
  • 60 W @ Passive PoE - Port LAN5,
  • 30 W @ PoE (802.3af/at) - LAN1 ... LAN5 ports  
  • ...  
    DC voltage measurement:  ...  0 V ... ± 440 V ± (2% + 3)  @ 1 V  
    Maximal total power:  60 W  ...  
    Measurement of small resistances:  ...  0.01 Ω ... 200 Ω ± (2% + 5)   
    Frequency measurement:  ...  20 Hz ... 100 Hz - for reference only  
    Operation modes:  
  • Standard : 100 m @ 10/100 Mb/s - LAN1 ... LAN6 ports
  • Long Range : 280 m @ 10 Mb/s - LAN1 ... LAN4 ports ; 100 m @ 10/100 Mb/s - LAN5, LAN6 ports  
  • ...  
    Test of RCDs:  ...  
  • Working voltage: 220V ± 10 %
  • Test current: 10mA / 30mA / 100mA / 300mA / 500mA
  • Switch-off time ranges :
    • 0 ... 2000 ms ± (5% + 5)  @ 1/2 x nominal value of the residual current
    • 0 ... 500 ms ± (5% + 5)  @ 1 x  nominal value of the residual current, Selective RCD
    • 0 ... 500 ms ± (5% + 5)  @ 2 x nominal value of the residual current, Selective RCD
    • 0 ... 300 ms ± (5% + 5)  @ 1 x nominal value of the residual current
    • 0 ... 300 ms ± (5% + 5)  @ 2 x nominal value of the residual current
    • 0 ... 40 ms ± (5% + 5)  @ 5 x nominal value of the residual current
     
  • RCD tripping current measurement:  ...  
    Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 %  
    RCD automatic test:  ...    
    Phase sequence test:  ...  100 V ... 440 V / 45 Hz ... 65 Hz  
    Continuity measurement of protective and equalizing conductors:  ...  0 Ω ... 199 Ω ± (2% + 5) 
    Measuring current > 20 mA @ 0 ... 2 Ω  
    Line impedance measurement (L-N):  ...  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    Short circuit loop impedance measurement (L-PE):  ...  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    Automatic change of measuring ranges:  ...    
    RS-232:  ...    
    USB:  ...    
    Main features:  
  • The ability to independently turn on and off the PoE power for each of the LAN 1 ... LAN 9 ports
  • The modular design streamlines service tasks and enables quick and easy system expansion
  • The raster system of module assembly facilitates the expansion of the device by further modules
  • Place for battery : 12 V / 18 Ah
  • Battery charging current : 1 A / 2 A - (set with the JP1 jumper)
  • Battery - Protection against reverse polarity connection, Protection against deep discharge of the battery
  • Technical outputs of the OC type signaling loss of voltage at the PSU output (OUF) and loss of voltage in the 230V mains (ACF)
  • PSU thermal protection : 130 °C
  • Overload protection
  • LAN & PoE ports - Short-circuit protection, Overvoltage
  • TAMPER switch indicating open the cover
  • "Index of Protection" : IP20  
  • Warning of using high voltage during the measurement,
  • Phase switch 0° / 180° during RCD test,
  • Automatic identification of AC/DC voltage,
  • Reset function for measuring low resistances,
  • Large, readable LCD display with backlight,
  • Buzzer,
  • Automatic power-off,
  • Low battery indicator,
  • Aesthetic and solid construction  
  • Operation temp:  ...  0 °C ... 40 °C  
    Permissible relative humidity:  ...  ≤ 85 % (non-condensing)  
    Power supply:  190  ... 260 V AC  8 x 1.5V, type AA/LR6/FR6 battery - included  
    Weight:  2.48 kg  1.1 kg  
    Dimensions:  325  x 305  x 100 mm  210  x 175  x 90 mm  
    Manufacturer / Brand:  ATTE  UNI-T  
    Guarantee:  3 years  2 years