Top Other Products  Overvoltage Protections  Safety Multi-Outlet Extension Cords AC 230V
Compare category Description:Sort:type | price | price a A A

Safety Multi-Outlet Extension Cords AC 230V

AXON-POWER/DIN
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Housing: DIN, TS-35 rail mounting ;
Net: 36.80 CAD  Gross: 45.26 CAD
LE-412223
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Device type: Overvoltage limiter, Three-phase ; Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 2 type ; Protection level Up L/PE, N/PE: 1.2 kV @ 8/20 µs (T2) ; Nominal discharge current (L/PE, N/PE): 5 kA @ 8/20 µs (T2) ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 121.51 CAD  Gross: 149.46 CAD
LE-412253
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Device type: Overvoltage limiter, Three-phase ; Rated voltage: 230 / 400 V AC ; Maximal voltage: 320 V AC ; Class: 1+2 type ; Protection level Up L/PE, N/PE: 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) ; Nominal discharge current (L/PE, N/PE): 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) ; Housing: DIN, TS-35 rail mounting ;
Net: 319.62 CAD  Gross: 393.13 CAD
LE-412297
Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 2 type ; Protection level Up : 1.2 kV @ 8/20 µs (T2) ; Nominal discharge current : 5 kA @ 8/20 µs (T2) ; Maximum stroke current: 20 kA @ 8/20 µs (T2) ;
Net: 34.02 CAD  Gross: 41.84 CAD
LE-412302
Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 1+2 type ; Protection level Up : 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) ; Nominal discharge current : 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) ; Maximum stroke current: 50 kA @ 8/20 µs (T2) ;
Net: 70.56 CAD  Gross: 86.79 CAD
ACAR-MINI-AGD
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 2 grounded outlets 10A/250V ;
Net: 14.64 CAD  Gross: 18.01 CAD
ACAR-P7
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V 2 non-grounded outlets 2.5A/250V ;
Net: 23.73 CAD  Gross: 29.19 CAD
LE-049419
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 16 A ; Maximal total load: 3680 W ; Number of outlets: 6 grounded outlets 16A/250V ;
Net: 57.10 CAD  Gross: 70.23 CAD
ACAR-504/WF/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 5 grounded outlets 10A/250V ;
Net: 53.27 CAD  Gross: 65.52 CAD
ACAR-F5/FA/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ; Housing: RACK 19", 1U ;
Net: 39.77 CAD  Gross: 48.92 CAD
ACAR-S8-DUAL
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 8 grounded outlets 10A/250V ;
Net: 35.13 CAD  Gross: 43.21 CAD
ACAR-S8/FA/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 8 grounded outlets 10A/250V ;
Net: 43.23 CAD  Gross: 53.17 CAD
ACAR-XPROTECTOR
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ;
Net: 29.65 CAD  Gross: 36.47 CAD
AK-SP-05A
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 1.8 m ;
Net: 11.70 CAD  Gross: 14.39 CAD
AK-SP-05B
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 3.0 m ;
Net: 13.13 CAD  Gross: 16.15 CAD
AK-SP-05U
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V, 2 USB ports 2A/5V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 1.5 m ;
Net: 20.93 CAD  Gross: 25.74 CAD
OR-AE-13144
Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 4 grounded outlets 10A/250V, 2 USB ports 2.1A/5V ; Length of the cable: 1.4 m ;
Net: 25.65 CAD  Gross: 31.55 CAD
OR-AE-13132
Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ; Socket type: CEE 7/5 E type ; Plug type: CEE 7/7 ; Length of the cable: 3 m ; Wireless: 433.92 MHz Operating range in open area : 30 m ; Main features: Remote controlled : Supports max. 5 devices ;
Net: 61.85 CAD  Gross: 76.08 CAD
ACAR-DIGITAL
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Protection level: ≤ 1.3 kV ; Nominal load current: 10 A (total) ; Main features: Easily readable LCD with backlight displaying detailed information on system state, Supply voltage measurement, Supply current measurement, Power measurement, Energy measurement ;
Net: 81.28 CAD  Gross: 99.97 CAD
ACAR-ECO-PLUS
It helps to reduce electricity consumption by auto switch off the stand-by devices; The extension cord is equipped with 3 SLAVE outlets controller by MASTER outlet and 2 separate ones; Maximal load power: 2300 W ; Fuse: 10 A / 250 V ; Protection level: 1.3 kV (L/N) ; Nominal stroke current: 2 kA (L/N) - (8/20µs) ;
Net: 85.48 CAD  Gross: 105.14 CAD
ACAR-SMART
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Protection level: ≤ 1.3 kV ; Nominal load current: 10 A (total) ;
Net: 32.32 CAD  Gross: 39.75 CAD