Top Other Products  Overvoltage Protections  Safety Multi-Outlet Extension Cords AC 230V
Compare category Description:Sort:type | price | price a A A

Safety Multi-Outlet Extension Cords AC 230V

AXON-POWER/DIN
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Housing: DIN, TS-35 rail mounting ;
Net: 628.69 CZK  Gross: 773.29 CZK
LE-412223
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Device type: Overvoltage limiter, Three-phase ; Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 2 type ; Protection level Up L/PE, N/PE: 1.2 kV @ 8/20 µs (T2) ; Nominal discharge current (L/PE, N/PE): 5 kA @ 8/20 µs (T2) ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 2 075.65 CZK  Gross: 2 553.05 CZK
LE-412253
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Device type: Overvoltage limiter, Three-phase ; Rated voltage: 230 / 400 V AC ; Maximal voltage: 320 V AC ; Class: 1+2 type ; Protection level Up L/PE, N/PE: 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) ; Nominal discharge current (L/PE, N/PE): 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) ; Housing: DIN, TS-35 rail mounting ;
Net: 5 459.98 CZK  Gross: 6 715.78 CZK
LE-412297
Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 2 type ; Protection level Up : 1.2 kV @ 8/20 µs (T2) ; Nominal discharge current : 5 kA @ 8/20 µs (T2) ; Maximum stroke current: 20 kA @ 8/20 µs (T2) ;
Net: 581.19 CZK  Gross: 714.86 CZK
LE-412302
Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 1+2 type ; Protection level Up : 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) ; Nominal discharge current : 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) ; Maximum stroke current: 50 kA @ 8/20 µs (T2) ;
Net: 1 205.42 CZK  Gross: 1 482.67 CZK
ACAR-MINI-AGD
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 2 grounded outlets 10A/250V ;
Net: 250.03 CZK  Gross: 307.54 CZK
ACAR-P7
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V 2 non-grounded outlets 2.5A/250V ;
Net: 405.36 CZK  Gross: 498.59 CZK
LE-049419
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 16 A ; Maximal total load: 3680 W ; Number of outlets: 6 grounded outlets 16A/250V ;
Net: 975.35 CZK  Gross: 1 199.68 CZK
ACAR-504/WF/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 5 grounded outlets 10A/250V ;
Net: 909.95 CZK  Gross: 1 119.24 CZK
ACAR-F5/FA/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ; Housing: RACK 19", 1U ;
Net: 679.39 CZK  Gross: 835.65 CZK
ACAR-S8-DUAL
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 8 grounded outlets 10A/250V ;
Net: 600.12 CZK  Gross: 738.15 CZK
ACAR-S8/FA/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 8 grounded outlets 10A/250V ;
Net: 738.46 CZK  Gross: 908.31 CZK
ACAR-XPROTECTOR
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ;
Net: 506.51 CZK  Gross: 623.01 CZK
AK-SP-05A
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 1.8 m ;
Net: 199.94 CZK  Gross: 245.93 CZK
AK-SP-05B
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 3.0 m ;
Net: 224.29 CZK  Gross: 275.88 CZK
AK-SP-05U
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V, 2 USB ports 2A/5V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 1.5 m ;
Net: 357.56 CZK  Gross: 439.80 CZK
OR-AE-13144
Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 4 grounded outlets 10A/250V, 2 USB ports 2.1A/5V ; Length of the cable: 1.4 m ;
Net: 438.10 CZK  Gross: 538.86 CZK
OR-AE-13132
Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ; Socket type: CEE 7/5 E type ; Plug type: CEE 7/7 ; Length of the cable: 3 m ; Wireless: 433.92 MHz Operating range in open area : 30 m ; Main features: Remote controlled : Supports max. 5 devices ;
Net: 1 056.60 CZK  Gross: 1 299.62 CZK
ACAR-DIGITAL
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Protection level: ≤ 1.3 kV ; Nominal load current: 10 A (total) ; Main features: Easily readable LCD with backlight displaying detailed information on system state, Supply voltage measurement, Supply current measurement, Power measurement, Energy measurement ;
Net: 1 388.43 CZK  Gross: 1 707.77 CZK
ACAR-ECO-PLUS
It helps to reduce electricity consumption by auto switch off the stand-by devices; The extension cord is equipped with 3 SLAVE outlets controller by MASTER outlet and 2 separate ones; Maximal load power: 2300 W ; Fuse: 10 A / 250 V ; Protection level: 1.3 kV (L/N) ; Nominal stroke current: 2 kA (L/N) - (8/20µs) ;
Net: 1 460.28 CZK  Gross: 1 796.14 CZK
ACAR-SMART
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Protection level: ≤ 1.3 kV ; Nominal load current: 10 A (total) ;
Net: 552.08 CZK  Gross: 679.06 CZK