- Show All - Show differences - Back | OVERVOLTAGE LIMITER AXON-POWER/DIN | OVERVOLTAGE LIMITER LE-412223 THREE-PHASE 2 TYPE LEGRAND | OVERVOLTAGE LIMITER LE-412253 THREE-PHASE 1+2 TYPE LEGRAND | PLUG-IN MODULE FOR OVERVOLTAGE LIMITER LE-412297 2 TYPE 20 kA LEGRAND | PLUG-IN MODULE FOR OVERVOLTAGE LIMITER LE-412302 1+2 TYPE 50 kA LEGRAND | MULTI-SOCKET PLUG WITH SURGE PROTECTION ACAR-MINI-AGD | POWER DISTRIBUTION UNIT ACAR-P7 (5 + 2 OUTLETS) | POWER DISTRIBUTION UNIT LE-049419 (6 OUTLETS) 1.5 m LEGRAND | POWER DISTRIBUTION UNIT ACAR-504/WF/RACK | POWER DISTRIBUTION UNIT ACAR-F5/FA/RACK | POWER DISTRIBUTION UNIT ACAR-S8-DUAL | POWER DISTRIBUTION UNIT ACAR-S8/FA/RACK | POWER DISTRIBUTION UNIT ACAR-XPROTECTOR | POWER DISTRIBUTION UNIT AK-SP-05A AKYGA | POWER DISTRIBUTION UNIT AK-SP-05B AKYGA | POWER DISTRIBUTION UNIT AK-SP-05U (5 OUTLETS + 2 USB) AKYGA | POWER DISTRIBUTION UNIT WITH REMOTE CONTROL OR-AE-13132 (5 OUTLETS) ORNO | POWER DISTRIBUTION UNIT OR-AE-13144 (4 OUTLETS + 2 USB) ORNO | POWER DISTRIBUTION UNIT ACAR-DIGITAL (5 OUTLETS) | POWER DISTRIBUTION UNIT ACAR-ECO-PLUS (6 OUTLETS) | POWER DISTRIBUTION UNIT ACAR-SMART (6 OUTLETS) |
| | | | | | | | | | | | | | | | | | | | | |
| 24.94 EUR 24.94 EUR
| 82.35 EUR 82.35 EUR
| 216.62 EUR 216.62 EUR
| 23.06 EUR 23.06 EUR
| 47.82 EUR 47.82 EUR
| 9.92 EUR 9.92 EUR
| 16.08 EUR 16.08 EUR
| 38.70 EUR 38.70 EUR
| 36.10 EUR 36.10 EUR
| 26.95 EUR 26.95 EUR
| 23.81 EUR 23.81 EUR
| 29.30 EUR 29.30 EUR
| 20.10 EUR 20.10 EUR
| 7.93 EUR 7.93 EUR
| 8.90 EUR 8.90 EUR
| 14.19 EUR 14.19 EUR
| 41.92 EUR 41.92 EUR
| 17.38 EUR 17.38 EUR
| 55.08 EUR 55.08 EUR
| 57.93 EUR 57.93 EUR
| 21.90 EUR 21.90 EUR
|
Nominal voltage: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | 230 V AC / 50 Hz | ... |
Total maximal current: | ... | ... | ... | ... | ... | 10 A | 10 A | 16 A | ... | ... | ... | ... | 10 A | 10 A | 10 A | 10 A | 10 A | 10 A | ... | ... | ... |
Device type: | ... | Overvoltage limiter, Three-phase | Overvoltage limiter, Three-phase | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Nominal load current: | ... | ... | ... | ... | ... | ... | ... | ... | ... | max. 10 A (total) | 10 A (total) | 10 A (total) | ... | ... | ... | ... | ... | ... | 10 A (total) | ... | 10 A (total) |
Maximal total load: | ... | ... | ... | ... | ... | 2300 W | 2300 W | 3680 W | ... | 2300 W | ... | ... | 2300 W | 2500 W | 2500 W | 2500 W | 2300 W | 2300 W | ... | ... | ... |
Maximal load power: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | 2300 W | 2300 W | ... |
Fuse: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | 10 A / 250 V | ... |
Rated current: | 10 A | ... | ... | ... | ... | ... | ... | ... | 10 A (total) | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Rated voltage: | 230 V AC / 50 Hz | 230 / 400 V AC, 50 / 60 Hz | 230 / 400 V AC, 50 / 60 Hz | 230 / 400 V AC, 50 / 60 Hz | 230 / 400 V AC, 50 / 60 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | 230 V AC / 50 Hz | ... | 230 V AC / 50 Hz |
Socket type: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | CEE 7/5 E type | ... | ... | ... | ... |
Protection level Up L/N: | ≤ 3 kV | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Plug type: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | CEE 7/7 | ... | ... | ... | ... |
Maximal voltage: | 250 V AC / 50 Hz | 320 V AC, 50 / 60 Hz | 320 V AC, 50 / 60 Hz | 320 V AC, 50 / 60 Hz | 320 V AC, 50 / 60 Hz | 250 V / 50 Hz | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Nominal discharge current (L/N, L/PE, N/PE): | 4 kA - 8/20 µs | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Protection level: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ≤ 1.3 kV | 1.3 kV (L/N) | ≤ 1.3 kV |
Class: | ... | 2 type ( Class C ) | 1+2 type ( Class B+C ) | 2 type ( Class C ) | 1+2 type ( Class B+C ) | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Protection level Up : | ... | ... | ... | 1.2 kV @ 8/20 µs (T2) | 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Automatic delayed fuse: | ... | ... | ... | ... | ... | ... | 10 A / 250 V | | ... | 10 A / 250 V | | | 10 A / 250 V | 10 A / 250 V | 10 A / 250 V | 10 A / 250 V | ... | ... | | ... | ... |
Leak current: | ... | ... | ... | ... | ... | ... | < 0.5 mA | ... | < 0.5 mA | ... | ... | < 0.5 mA | < 0.5 mA | ... | ... | ... | ... | ... | < 0.5 mA | < 0.5 mA | < 0.5 mA |
Wireless: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | 433.92 MHz Remote control Operating range in open area : 30 m | ... | ... | ... | ... |
Protection level Up L/PE, N/PE: | ≤ 1.3 kV | 1.2 kV @ 8/20 µs (T2) | 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
DC filter to eliminate interferences: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | RFI ≤ 10 dB | RFI ≤ 10 dB | RFI ≤ 10 dB | ... | ... | ... | ... | ... |
Number of outlets: | ... | ... | ... | ... | ... | 2 grounded outlets 10A/250V | 5 grounded outlets 10A/250V 2 non-grounded outlets 2.5A/250V | 6 grounded outlets 16A/250V - CEE 7/5 | 5 grounded outlets 10A/250V | 5 grounded outlets 10A/250V | 8 grounded outlets 10A/250V | 8 grounded outlets 10A/250V | 5 grounded outlets 10A/250V | 5 grounded outlets 10A/250V | 5 grounded outlets 10A/250V | 5 grounded outlets 10A/250V, 2 USB ports 2A/5V | 5 grounded outlets 10A/250V | 4 grounded outlets 10A/250V, 2 USB ports 2.1A/5V | 5 grounded outlets 16A/250V - (Schuko) | ... | ... |
Electric shock protection system: | ... | ... | ... | ... | ... | Ground connectors (pins) connected with ground wire of AC mains | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | Ground connectors (pins) connected with ground wire of AC mains | ... |
Nominal voltage of surge suppressor: | ... | ... | ... | ... | ... | ... | 250 V / 50 Hz | 275 V / 50 Hz | 250 V / 50 Hz | 250 V / 50 Hz | 250 V / 50 Hz | 250 V / 50 Hz | 250 V / 50 Hz | 250 V / 50 Hz | 250 V / 50 Hz | 250 V / 50 Hz | ... | ... | ... | 250 V | ... |
Nominal discharge current : | ... | ... | ... | 5 kA @ 8/20 µs (T2) | 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Maximum energy absorption: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | 150 J | 150 J | 150 J | ... | ... | ... | ... | ... |
Response time: | ... | ... | ... | ... | ... | < 25 ns | < 25 ns | ... | < 25 ns | < 25 ns | < 25 ns | < 25 ns | < 25 ns | < 25 ns | < 25 ns | < 25 ns | ... | ... | < 25 ns | < 25 ns | < 25 ns |
Protection level of surge suppressor: | ... | ... | ... | ... | ... | ≤ 1.3 kV (L/N) | ≤ 1.3 kV (L/N) | < 1.5 kV (L/N) | ≤ 1.3 kV (L/N) | ≤ 1.3 kV (L/N) | ≤ 1.3 kV (L/N) | ≤ 1.3 kV (L/N) | ≤ 1.3 kV (L/N) | ... | ... | ... | ... | ... | ... | ... | ... |
Nominal discharge current (L/PE, N/PE): | ... | 5 kA @ 8/20 µs (T2) | 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Nominal stroke current: | ... | ... | ... | ... | ... | 2 kA (L/N) - (8/20µs) | 2 kA (L/N) - (8/20µs) | 1.5 kA (L/N) - (8/20µs) | 2.5 kA (L/N) - 8/20 µs | 2 kA (L/N) - 8/20 µs | 2 kA (L/N) - 8/20 µs | 2 kA (L/N) - 8/20 µs | 1 kA (L/N) - (8/20µs) | ... | ... | ... | ... | ... | 2 kA (L/N) - 8/20 µs | 2 kA (L/N) - (8/20µs) | 2 kA (L/N) 8/20 µs 8/20 µs |
Number of output outlets: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | 1 MASTER outlet, two-contact with ground contact 3 SLAVE outlets with auto switch off the power supply after switch off the receiver powered from MASTER outlet 2 outlets separate from MASTER outlet | 6 |
Maximum stroke current (L/N, L/PE, N/PE): | 10 kA 8/20 µs (type 2) | 20 kA @ 8/20 µs (T2) | 50 kA @ 8/20 µs (T2) | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Operation state indication: | | | | | | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Connectors type: | 2 x terminals | screw terminals | screw terminals | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Operation temp: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | 5 °C ... 50 °C | 5 °C ... 50 °C | 5 °C ... 50 °C | ... | ... | ... | ... | ... |
Switch: | ... | ... | ... | ... | ... | ... | two-way, with light indication | with light indication | two-way, with light indication | two-way, with light indication | two-way, with light indication | two-way, with light indication | two-way, with light indication | with light indication | with light indication | with light indication | | | Two-way switch - with light indication | two-way | 2 pcs |
Maximum stroke current: | ... | ... | ... | 20 kA @ 8/20 µs (T2) | 50 kA @ 8/20 µs (T2) | 10 kA (L/N) - (8/20µs) | 6.5 kA (L/N) - (8/20µs) | ... | 6.5 kA (L/N) - 8/20 µs | 10 kA (L/N) - 8/20 µs 2 type | 6.5 kA (L/N) - 8/20 µs | 6.5 kA (L/N) - 8/20 µs | 4.5 kA (L/N) - (8/20µs) | 4.5 kA | 4.5 kA | 4.5 kA | ... | ... | 6.5 kA (L/N) - 8/20 µs | 6.5 kA (L/N) - (8/20µs) | 6.5 kA (L/N) |
Width in 17.5 mm modules: | ... | 4 | 4 | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Main features: | ... | ... | ... | Varistor | Varistor | ... | ... | Mounting brackets for screwing the device to a flat surface or mounting with fastening ties The body of the device rotates in the range of 180° relative to the mounting brackets Outlets protected with a protection shutter LED indication : Power supply, Overvoltage protection | ... | Current paths shutters DC filter to eliminate interferences : ≤ 35 dB | ... | ... | ... | ... | ... | ... | radio remote controller in the set Remote controlled : Supports max. 5 devices LED indicators displaying the device's operating status Overload protection Current paths shutters Insulation - PVC Wire gauge : 3 x 1.5 mm² "Index of Protection" : IP20 | ... | ... | ... | ... |
Color: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | Black | Black | Black | Black | White + Gray | ... | ... | ... |
Power supply: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | 230 V AC, 50 Hz Remote control : 12V, type A23 battery (included) | ... | ... | ... | ... |
Main features: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | Easily readable LCD with backlight displaying detailed information on system state, Supply voltage measurement : 80 V ... 250 V @ 50Hz, Supply current measurement : 0.01 A ... 10 A @ 50/60 Hz, Power measurement : 1 W ... 2500 W, Energy measurement : 1 Wh ... 9999 Wh Energy meter reset Setting the alarm after exceeding the power consumption | ... | ... |
Length of the cable: | ... | ... | ... | ... | ... | ... | 1.45 m | 1.5 m | 2.7 m | 2.9 m | 1.4 m | 2.9 m | 1.45 m | 1.8 m | 3.0 m | 1.5 m | 3 m | 1.4 m | 3 m | 1.45 m | 1.4 m |
Housing: | Plastic DIN, TS-35 rail mounting | Plastic, DIN, TS-35 rail mounting | Plastic, DIN, TS-35 rail mounting | Plastic | Plastic | Plastic - non-flammable | Plastic - non-flammable | Plastic | RACK 19", 1U, Plastic - non-flammable | RACK 19", 1U, Plastic - non-flammable | Plastic - non-flammable | RACK 19", 1U, Plastic - non-flammable | Plastic - non-flammable | Plastic (ABS) | Plastic (ABS) | Plastic (ABS) | Plastic | Plastic | Plastic - non-flammable | Plastic - non-flammable | Plastic - non-flammable |
Weight: | 0.075 kg | 0.334 kg | 0.552 kg | 0.042 kg | 0.098 kg | 0.12 kg | 0.44 kg | 0.59 kg | 0.59 kg | 0.93 kg | 0.52 kg | 0.61 kg | 0.51 kg | 0.306 kg | 0.372 kg | 0.318 kg | 0.92 kg | 0.35 kg | 0.65 kg | 0.56 kg | 0.4 kg |
Manufacturer / Brand: | ... | LEGRAND | LEGRAND | LEGRAND | LEGRAND | ... | ... | LEGRAND | ... | ... | ... | ... | ... | AKYGA | AKYGA | AKYGA | ORNO | ORNO | ... | ... | ... |
Dimensions: | 86 x 58 x 35 mm | 71 x 83 x 70 mm | 71 x 83 x 70 mm | 62 x 54 x 17 mm | 62 x 54 x 17 mm | 131 x 55 x 75 mm | 370 x 65 x 44 mm | 423 x 66 x 100 mm | 383 x 58 x 55 mm | 484 x 54 x 55 mm | 445 x 54 x 55 mm | 445 x 54 x 55 mm | 365 x 65 x 52 mm | 305 x 50 x 40 mm | 305 x 50 x 40 mm | 305 x 50 x 40 mm | 390 x 68 x 45 mm | 94 x 78 x 78 mm | 447 x 57 x 43 mm | 447 x 55 x 53 mm | 138 x 100 x 63 mm |
Guarantee: | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years |