Top Power Supply  Relay Modules  12V DC
Compare category Description:Sort:type | price | price a A A

12V DC

PK1-12-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Screw mounting with spacers, Protections : Overvoltage, Reverse polarity connection ;
Net: 124.33 CZK  Gross: 152.93 CZK
UPK-1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V AC/DC ; Relay maximal load: 1 A @ 30 V AC/DC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 2 A ;
Net: 123.31 CZK  Gross: 151.67 CZK
AWZ-510
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC, 10 ... 13 V AC ; Relay maximal load: 1 A (max) 30 V DC / 50 V AC ; Output: 1 x NO/NC ;
Net: 107.85 CZK  Gross: 132.66 CZK
P-HF41F-012-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 101.86 CZK  Gross: 125.29 CZK
AWZ-622
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 1 x NO / NC ;
Net: 71.90 CZK  Gross: 88.44 CZK
PK-552
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Current consumption: 111 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
Net: 60.28 CZK  Gross: 74.14 CZK
PK-551
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Current consumption: 65 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 1 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
Net: 36.31 CZK  Gross: 44.66 CZK