Top Power Supply  Relay Modules  12V DC
Compare category Description:Sort:type | price | price a A A

12V DC

PK-41F-1Z-C2-1/12V
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 54.33 PLN  Gross: 66.83 PLN
P-HF41F-012-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 17.00 PLN  Gross: 20.91 PLN
PK1-12-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 27.83 PLN  Gross: 34.23 PLN
PK1-12-ZN
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
Net: 23.12 PLN  Gross: 28.44 PLN
PK1-12-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Screw mounting with spacers, Protections : Overvoltage, Reverse polarity connection ;
Net: 20.75 PLN  Gross: 25.52 PLN
ARM7011-W2(868)
Number of relay outputs: ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Wireless: 868 MHz - Bidirectional communication, Range : 1200 m (in open area) ; Main features: LED indication, alarm input - Tamper signaling ;
Net: 217.00 PLN  Gross: 266.91 PLN
DS-PM1-O1L-WE
Number of relay outputs: ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Main features: Wireless 868 MHz, LED indication, alarm input ;
Net: 208.00 PLN  Gross: 255.84 PLN
PK1-12-PDT
The PK1-12-PDT module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: DIN, TS-35 rail mounting, ;
Net: 51.64 PLN  Gross: 63.52 PLN
PK1-12-PST
The PK1-12-PST module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: Screw mounting with spacers, ;
Net: 39.16 PLN  Gross: 48.17 PLN
PK2-12-PWT
Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: max. 2 x 10 A, 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: LED indication, Splash-proof casing ;
Net: 70.86 PLN  Gross: 87.16 PLN
PK4-12-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO/NC ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 89.26 PLN  Gross: 109.79 PLN
PK4-12-ZN/S
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Mounting with self-adhesive bases, Screw mounting with spacers Protections : Overvoltage, Reverse polarity connection ;
Net: 83.29 PLN  Gross: 102.45 PLN
PK4-12-ZW
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Protections : Overvoltage, Reverse polarity connection Splash-proof casing ;
Net: 66.16 PLN  Gross: 81.38 PLN
RD-8
The Modbus RD-8 digital output module has 8 transistor outputs; The outputs can take two states: ground potential or power input potential; PTZ control: RS-485 ; Current efficiency: 2 A (single output), 8 A (total) ; Inputs protection;
Net: 124.32 PLN  Gross: 152.91 PLN
2R-D7
PTZ control: RS-485 / UART TTL ; Protocol: Modbus RTU ; Transmission speed: 4800 / 9600 / 19200 b/s ; Number of relay outputs: 2 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 39.98 PLN  Gross: 49.18 PLN
4R-D7
PTZ control: RS-485 / UART TTL ; Protocol: Modbus RTU ; Transmission speed: 4800 / 9600 / 19200 b/s ; Number of relay outputs: 4 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 51.20 PLN  Gross: 62.98 PLN
ESP12-2R-D8
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 2 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 46.40 PLN  Gross: 57.07 PLN
ESP12-4R-MV
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 4 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 61.73 PLN  Gross: 75.93 PLN
ESP12-8R-D8
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of inputs: ; Number of relay outputs: 8 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 88.00 PLN  Gross: 108.24 PLN
AWZ-508
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 15 V DC, 21 ... 28 V DC (set by jumpers) ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - T+ / T- input LED indication ;
Net: 51.12 PLN  Gross: 62.88 PLN
AWZ-510
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC, 10 ... 13 V AC ; Relay maximal load: 1 A (max) 30 V DC / 50 V AC ; Output: 1 x NO/NC ;
Net: 18.00 PLN  Gross: 22.14 PLN
AWZ-511
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max) 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 34.00 PLN  Gross: 41.82 PLN
AWZ-512
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 28.00 PLN  Gross: 34.44 PLN
AWZ-513
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 0.5 A, 2 A ;
Net: 38.00 PLN  Gross: 46.74 PLN
AWZ-514
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
Net: 31.09 PLN  Gross: 38.24 PLN
AWZ-520
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 5 x NO/NC ;
Net: 54.00 PLN  Gross: 66.42 PLN
AWZ-529
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 29.00 PLN  Gross: 35.67 PLN
AWZ-622
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 1 x NO / NC ;
Net: 9.60 PLN  Gross: 11.81 PLN
AWZ-626
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 4 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
Net: 106.00 PLN  Gross: 130.38 PLN
B31
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 15 V DC - no polarization ; Relay maximal load: 2 A / 30 V ; Output: 1 x NO / NC ;
Net: 85.00 PLN  Gross: 104.55 PLN
MP-1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 2 x 4 A / 48 V DC/AC 2 x 8 A / 250 V DC / 400 V AC ; Output: 4x NO/NC ;
Net: 88.00 PLN  Gross: 108.24 PLN
PK-551
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Current consumption: 65 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 1 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
Net: 6.06 PLN  Gross: 7.45 PLN
PK-552
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Current consumption: 111 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
Net: 10.06 PLN  Gross: 12.37 PLN
UPK-1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V AC/DC ; Relay maximal load: 1 A @ 30 V AC/DC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 2 A ;
Net: 20.58 PLN  Gross: 25.31 PLN
UPK-2.1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 2 A @ 30 V AC / DC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 2 A ;
Net: 22.64 PLN  Gross: 27.85 PLN
UPK-2.2
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 1 A @ 30 V AC / DC ; Output: 2 x NO/NC ;
Net: 22.64 PLN  Gross: 27.85 PLN
OR-PI-457/1/UNI
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V ... 230 V AC / DC ; Relay maximal load: 16 A / 250 V AC ; Output: 1 x NO/NC ; Manufacturer / Brand: ORNO ;
Net: 89.01 PLN  Gross: 109.48 PLN
OR-PI-457/3/UNI
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V ... 240 V AC / DC ; Relay maximal load: 8 A / 250 V AC ; Output: 3 x NO/NC ; Manufacturer / Brand: ORNO ;
Net: 135.34 PLN  Gross: 166.47 PLN
AWZ-516
Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 10 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: EEPROM non-volatile memory, Time settings range 1 s ... 99 h, ;
Net: 107.00 PLN  Gross: 131.61 PLN
AWZ-525
Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max) @ 30 V DC / 50 V AC ; Output: 1 x NO/NC ; Main features: Time settings range 1. Range : 1 s ... 60 s, 2. Range : 5 s ... 5 minutes ;
Net: 61.00 PLN  Gross: 75.03 PLN