TopProducts Comparison
- Show All
- Show differences
- Back

INSULATION STRIPPER HT-332


USB SWITCH US-221A ATEN


USB SOCKET TESTER UT-658 UNI-T


CHARGER MW-SC4B MW POWER


MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-593 UNI-T

1228.85 HUF
1228.85 HUF

14338.46 HUF
14338.46 HUF

4060.58 HUF
4060.58 HUF

9503.85 HUF
9503.85 HUF

140292.31 HUF
140292.31 HUF

Material:  PET  ...  ...  ...  ...  
Device type:  ...  ...  Power meter via USB port  ...  ...  
Input socket type:  ...  ...  1 x USB-A plug  ...  ...  
Output socket type:  ...  ...  1 x USB-A socket  ...  ...  
Battery type:  ...  ...  ...  6 V, 12 V : Lead-Acid, Sealed lead-acid, AGM  ...  
Connectors:  ...  
  • 2 x socket USB 2.0 B - Computer interface
  • 1 x socket USB 2.0 A - Connecting to the device  
  • ...  ...  ...  
    Application:  Coaxial cable RG58 RG59 RG6  ...  ...  ...  ...  
    Length of the cable:  ...  180 cm  ...  ...  ...  
    USB standard:  ...  2.0   ...  ...  ...  
    DC current measurement:  ...  ...  0  ... 3 A ± 1 %  ...  ...  
    Battery capacity:  ...  ...  ...  
  • 6 V : 1.2 Ah ... 14 Ah,
  • 12 V : 1.2 Ah ... 120 Ah  
  • ...  
    Battery capacity measurement:  ...  ...  0  ... 9999 mAh  ...  ...  
    Housing:  ...  ...  Plastic  ...  ...  
    Resistance measurement:  ...  ...  ...  ...  
  • Test voltage 250 V : 0.05 MΩ ... 250 MΩ
  • Test voltage 500 V : 0.05 MΩ ... 500 MΩ
  • Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ  
  • Measuring accuracy:  ...  ...  ...  ...  0.05 MΩ ... 1000 MΩ ± (5% + 5)   
    Open circuit voltage:  ...  ...  ...  ...  Test voltage ± 10 %  
    Test current:  ...  ...  ...  ...  0.9 mA ... 1.1 mA  
    Short-circuit current:  ...  ...  ...  ...  < 1.8 mA  
    Battery charging current:  ...  ...  ...  
  • 6 V : 1 A ± 10 %,
  • 12 V : 1 A / 4 A ± 10 %  
  • ...  
    AC voltage measurement:  ...  ...  ...  ...  0 V ... 440 V ± (2% + 3)  @ 1 V  
    Battery charging voltage:  ...  ...  ...  
  • 7.2 V / 7.4 V DC ± 25 %
  • 14.4 V / 14.7 V DC ± 25 %  
  • ...  
    LED indicator:  ...  ...  ...    ...  
    LCD display:  ...  ...  1.22 "    ...  
    DC voltage measurement:  ...  ...  3  ... 9 V ± 1 %  ...  0 V ... ± 440 V ± (2% + 3)  @ 1 V  
    Measurement of small resistances:  ...  ...  ...  ...  0.01 Ω ... 200 Ω ± (2% + 5)   
    Length of the cables:  ...  ...  ...  
  • 1.45 m - Battery cable
  • 1.50 m - Power cord  
  • ...  
    Frequency measurement:  ...  ...  ...  ...  20 Hz ... 100 Hz - for reference only  
    Power consumption:  ...  ...  ...  max. 70 W  ...  
    "Index of Protection":  ...  ...  ...  IP65  ...  
    Isolation class:  ...  ...  ...  Class II  ...  
    Test of RCDs:  ...  ...  ...  ...  
  • Working voltage: 220V ± 10 %
  • Test current: 10mA / 30mA / 100mA / 300mA / 500mA
  • Switch-off time ranges :
    • 0 ... 2000 ms ± (5% + 5)  @ 1/2 x nominal value of the residual current
    • 0 ... 500 ms ± (5% + 5)  @ 1 x  nominal value of the residual current, Selective RCD
    • 0 ... 300 ms ± (5% + 5)  @ 1 x nominal value of the residual current
    • 0 ... 40 ms ± (5% + 5)  @ 5 x nominal value of the residual current
     
  • RCD tripping current measurement:  ...  ...  ...  ...  
    Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 %  
    RCD automatic test:  ...  ...  ...  ...    
    Phase sequence test:  ...  ...  ...  ...  100 V ... 440 V / 45 Hz ... 65 Hz  
    Continuity measurement of protective and equalizing conductors:  ...  ...  ...  ...  0 Ω ... 199 Ω ± (2% + 5) 
    Measuring current > 20 mA @ 0 ... 2 Ω  
    Line impedance measurement (L-N):  ...  ...  ...  ...  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    Short circuit loop impedance measurement (L-PE):  ...  ...  ...  ...  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    Automatic change of measuring ranges:  ...  ...  ...  ...    
    RS-232:  ...  ...  ...  ...    
    USB:  ...  ...  ...  ...    
    Main features:  Left shield width adjustment  
  • LED indication
  • Support for platforms: Windows, Linux, Mac, Sun
  • Overload protection
  • USB A / USB B cable included - 1.8 m  
  • ...  
  • Microprocessor control system
  • Fully automatic 10-stage charging process
  • Keeping the battery charged
  • Detection and regeneration of an exhausted battery
  • Short-circuit protection, Overvoltage
  • Overcharge protection
  • Thermal protection
  • Protection against reverse polarity connection
  • Insulated crocodile clips
  • The device is designed to work both inside and outside the building  
  • Warning of using high voltage during the measurement,
  • Phase switch 0° / 180° during RCD test,
  • Automatic identification of AC/DC voltage,
  • Reset function for measuring low resistances,
  • Large, readable LCD display with backlight,
  • Buzzer,
  • Automatic power-off,
  • Low battery indicator,
  • Aesthetic and solid construction  
  • Operation temp:  ...  ...  ...  -10 °C ... 40 °C  0 °C ... 40 °C  
    Permissible relative humidity:  ...  ...  ...  ...  ≤ 85 % (non-condensing)  
    Power supply:  ...  ...  5 V DC - Port USB  220  ... 240 V AC / 50 Hz  8 x 1.5V, type AA/LR6/FR6 battery - included  
    Weight:  ...  0.05 kg  0.02 kg  0.4 kg  1.1 kg  
    Dimensions:  ...  72  x 66  x 25 mm  84  x 29  x 12 mm  194  x 75  x 42 mm  210  x 175  x 90 mm  
    Manufacturer / Brand:  ...  ATEN  UNI-T  MW POWER  UNI-T  
    Guarantee:  2 years  2 years  2 years  2 years  2 years