TopProducts Comparison
- Show All
- Show differences
- Back

VOLTAGE DISTRIBUTION PANEL A19-TS-35/PD-3U


INSULATION RESISTANCE METER + RCD TESTER UT-526 UNI-T


UPS AT-UPS1200BK-LCD 1200 VA EAST

41.68 EUR
41.68 EUR

215.69 EUR
215.69 EUR

114.33 EUR
114.33 EUR

Width:  19 "  ...  ...  
Nominal power:  ...  ...  720 W  
Height:  3 U  ...  ...  
Apparent Power:  ...  ...  1200 VA  
Material:  Steel - powder painted  ...  ...  
Input voltage:  ...  ...  173 V ... 287 V AC  
Color:  Black (RAL 9005)  ...  ...  
"Index of Protection":  IP20  ...  ...  
Input frequency:  ...  ...  50  / 60 Hz (auto detection)  
Output voltage:  ...  ...  230 V AC ± 10 % (Approximated Sine Wave)  
Output frequency:  ...  ...  50  / 60 Hz ± 1 %  
Transfer time:  ...  ...  2 ... 7 ms (typical), max. 10 ms  
Resistance measurement:  ...  
  • Test voltage 250 V : 0.05 MΩ ... 200 MΩ
  • Test voltage 500 V : 0.05 MΩ ... 300 MΩ
  • Test voltage 1000 V : 0.05 MΩ ... 500 MΩ  
  • ...  
    Charging time (recover to 90% capacity):  ...  ...  8 hours  
    Battery:  ...  ...  2 pcs - 12V/7Ah  
    Measuring accuracy:  ...  0.05 MΩ ... 500 MΩ ± (5% + 5)   ...  
    Open circuit voltage:  ...  Test voltage + 10 %  ...  
    Test current:  ...  0.9 mA ... 1.1 mA  ...  
    Short-circuit current:  ...  < 1.8 mA  ...  
    Estimated battery operation time:  ...  ...  
  • 57 minutes @ 100 W
  • 14 minutes @ 300 W
  • 8 minutes @ 500 W  
  • Number of outputs:  ...  ...  3 pcs CEE 7/3 (Schuko)  
    AC voltage measurement:  ...  0 V ... 440 V ± (2% + 3)  @ 1 V  ...  
    DC voltage measurement:  ...  0 V ... 440 V ± (2% + 3)  @ 1 V  ...  
    Protections:  ...  ...  
  • Fuse
  • Overvoltage
  • Overload protection
  • Overcharge protection
  • Ethernet line filter  
  • Measurement of small resistances:  ...  0.01 Ω ... 2000 Ω ± (2% + 5)   ...  
    Operation state indication:  ...  ...  
  • LCD display: operation mode, battery charging level, in/out voltage level,
  • Sound signaling  
  • Frequency measurement:  ...  20 Hz ... 100 Hz - for reference only  ...  
    Application:  RACK 19"  ...  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Housing type:  ...  ...  Tower  
    Operation temp. / Relative humidity:  ...  ...  0 °C ... 40 °C / 20  ... 90 %  
    Test of RCDs:  ...  
  • Working voltage: 220V ± 10 %
  • Test current: 10mA / 30mA / 100mA / 300mA
  • Switch-off time ranges :
    • 0 ... 2000 ms ± (5% + 2)  @ 10 mA
    • 0 ... 500 ms ± (5% + 2)  @ 30 mA
    • 0 ... 300 ms ± (5% + 2)  @ 100 mA
    • 0 ... 300 ms ± (5% + 2)  @ 300 mA
     
  • ...  
    Automatic change of measuring ranges:  ...  
     
    ...  
    RS-232:  ...  
     
    ...  
    USB:  ...  
     
    ...  
    Main features:  
  • TH-35 rail
  • Corrosion resistance
  • Possibility to mount of 24 fuses, 1 S wide
  • 6-point fixing to the front RACK rails
  • 6 pcs. of M6 screws with cage nuts included
  • The enclosure features labeling field 420x20 mm  
  • Warning of using high voltage during the measurement,
  • Phase switch 0° / 180° during RCD test,
  • Automatic identification of AC/DC voltage,
  • Large, readable LCD display with backlight,
  • Buzzer,
  • Low battery level alarm,
  • Aesthetic and solid construction  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Configurable alarm  
  • Operation temp:  -10 °C ... 40 °C  0 °C ... 40 °C  ...  
    Permissible relative humidity:  ...  ≤ 85 % (non-condensing)  ...  
    Power supply:  ...  6 x 1.5V, type AA/LR6/FR6 battery - included  ...  
    Weight:  2.06 kg  0.45 kg  8.57 kg  
    Dimensions:  445  x 125  x 55 mm Internal dimensions
    481  x 132  x 135 mm External dimensions  
    150  x 100  x 71 mm  348  x 173  x 140 mm  
    Manufacturer / Brand:  PULSAR  UNI-T  EAST  
    Guarantee:  2 years  2 years  2 years