- Show All - Show differences - Back | VOLTAGE DISTRIBUTION PANEL A19-TS-35/PD-3U | INSULATION RESISTANCE METER + RCD TESTER UT-526 UNI-T | UPS AT-UPS1200BK-LCD 1200 VA EAST |
| | | |
| 41.68 EUR 41.68 EUR
| 215.69 EUR 215.69 EUR
| 114.33 EUR 114.33 EUR
|
Width: | 19 " | ... | ... |
Nominal power: | ... | ... | 720 W |
Height: | 3 U | ... | ... |
Apparent Power: | ... | ... | 1200 VA |
Material: | Steel - powder painted | ... | ... |
Input voltage: | ... | ... | 173 V ... 287 V AC |
Color: | Black (RAL 9005) | ... | ... |
"Index of Protection": | IP20 | ... | ... |
Input frequency: | ... | ... | 50 / 60 Hz (auto detection) |
Output voltage: | ... | ... | 230 V AC ± 10 % (Approximated Sine Wave) |
Output frequency: | ... | ... | 50 / 60 Hz ± 1 % |
Transfer time: | ... | ... | 2 ... 7 ms (typical), max. 10 ms |
Resistance measurement: | ... | Test voltage 250 V : 0.05 MΩ ... 200 MΩ Test voltage 500 V : 0.05 MΩ ... 300 MΩ Test voltage 1000 V : 0.05 MΩ ... 500 MΩ | ... |
Charging time (recover to 90% capacity): | ... | ... | 8 hours |
Battery: | ... | ... | 2 pcs - 12V/7Ah |
Measuring accuracy: | ... | 0.05 MΩ ... 500 MΩ ± (5% + 5) | ... |
Open circuit voltage: | ... | Test voltage + 10 % | ... |
Test current: | ... | 0.9 mA ... 1.1 mA | ... |
Short-circuit current: | ... | < 1.8 mA | ... |
Estimated battery operation time: | ... | ... | 57 minutes @ 100 W 14 minutes @ 300 W 8 minutes @ 500 W |
Number of outputs: | ... | ... | 3 pcs CEE 7/3 (Schuko) |
AC voltage measurement: | ... | 0 V ... 440 V ± (2% + 3) @ 1 V | ... |
DC voltage measurement: | ... | 0 V ... 440 V ± (2% + 3) @ 1 V | ... |
Protections: | ... | ... | Fuse Overvoltage Overload protection Overcharge protection Ethernet line filter |
Measurement of small resistances: | ... | 0.01 Ω ... 2000 Ω ± (2% + 5) | ... |
Operation state indication: | ... | ... | LCD display: operation mode, battery charging level, in/out voltage level, Sound signaling |
Frequency measurement: | ... | 20 Hz ... 100 Hz - for reference only | ... |
Application: | RACK 19" | ... | Surveillance Systems data storage centers network, servers, workstations Industrial Equipment |
Housing type: | ... | ... | Tower |
Operation temp. / Relative humidity: | ... | ... | 0 °C ... 40 °C / 20 ... 90 % |
Test of RCDs: | ... | Working voltage: 220V ± 10 % Test current: 10mA / 30mA / 100mA / 300mA Switch-off time ranges :
- 0 ... 2000 ms ± (5% + 2) @ 10 mA
- 0 ... 500 ms ± (5% + 2) @ 30 mA
- 0 ... 300 ms ± (5% + 2) @ 100 mA
- 0 ... 300 ms ± (5% + 2) @ 300 mA
| ... |
Automatic change of measuring ranges: | ... | | ... |
RS-232: | ... | | ... |
USB: | ... | | ... |
Main features: | TH-35 rail Corrosion resistance Possibility to mount of 24 fuses, 1 S wide 6-point fixing to the front RACK rails 6 pcs. of M6 screws with cage nuts included The enclosure features labeling field 420x20 mm | Warning of using high voltage during the measurement, Phase switch 0° / 180° during RCD test, Automatic identification of AC/DC voltage, Large, readable LCD display with backlight, Buzzer, Low battery level alarm, Aesthetic and solid construction | Auto restart while AC is recovering Automatic Voltage Regulator (AVR) Compatible with power generators Remote management - UPSmart application included Built-in EMI, RFI filter Configurable alarm |
Operation temp: | -10 °C ... 40 °C | 0 °C ... 40 °C | ... |
Permissible relative humidity: | ... | ≤ 85 % (non-condensing) | ... |
Power supply: | ... | 6 x 1.5V, type AA/LR6/FR6 battery - included | ... |
Weight: | 2.06 kg | 0.45 kg | 8.57 kg |
Dimensions: | 445 x 125 x 55 mm Internal dimensions 481 x 132 x 135 mm External dimensions | 150 x 100 x 71 mm | 348 x 173 x 140 mm |
Manufacturer / Brand: | PULSAR | UNI-T | EAST |
Guarantee: | 2 years | 2 years | 2 years |