NORMALLY OPEN RELAY MODULE PK4-12-ZW


WIRELESS GAS DETECTOR JA-80G JABLOTRON

15.68 EUR
15.68 EUR

Number of relay outputs:  4   ...  
Power consumption:  ...  2 W, II Protection Class  
Detection method:  ...  Platinum wire  
Sound pressure level:  ...  94 dB / 0.3 m  
Current consumption:  35 mA per each relay at voltage 12 V DC  ...  
Relay output:  ...  Optional for 1-st and 2-nd level, max. AC 230V / 5A  
Alarm memory:  ...  2 Set by #2 switch  
Response time:  ...  10 s  
Relay maximal load:  10 A (max), 30 V DC / 50 V AC (max)  ...  
Frequency range:  ...  868 MHz OASiS protocol  
Output:  4 x NO  ...  
Radio communication range (at open area):  ...  min. 200 m  
Application:  relay for electromagnetic lock/electric strike  ...  
Main features:  
  • LED indication,
  • Protections : Overvoltage, Reverse polarity connection
  • Splash-proof casing  
  • ...  
    Operation temp:  -25 °C ... 70 °C  -10 °C ... 40 °C IP30  
    Power supply:  10  ... 16 V DC  220 V ... 240 V AC @ 50Hz  
    Compliance with standards:  ...  EN 61779-1,4, ETSI EN 300220, EN 60950, EN 50130-4, EN 55022
    Can be operated accorded to ERC REC 70-03  
    Security class:  ...  OPTEX compliance  
    Methane:  ...  1. level 10 ± 2 % LEL (0.44% methane)
    2. level 17 ± 3 % LEL (0.75% methane)  
    Propane:  ...  1. level 15 ± 3 % LEL (0.26% propane)
    2. level 30 ± 3 % LEL (0.51% propane)  
    Iso-buthane:  ...  1. level 15 ± 3 % LEL (0.20% iso-butane)
    2. level 30 ± 3 % LEL (0.39% iso-butane)  
    Dimensions:  118  x 91  x 37 mm  100  x 73  x 39 mm  
    Weight:  0.12 kg  0.210 kg  
    Manufacturer / Brand:  DELTA  JABLOTRON  
    Guarantee:  3 years  2 years