- Show All - Show differences - Back | POWER SUPPLY DISTRIBUTOR LZ-12/R19 | ACCESS CONTROLLER ASC2202B-S DAHUA | ACCESS CONTROL PANEL CPR32-SE-BRD ROGER |
| | | |
| 30.44 CHF 30.44 CHF
| 200.63 CHF 200.63 CHF
| 147.03 CHF 147.03 CHF
|
Number of served transitions: | ... | 2 (one-way) | ... |
Number of power outputs: | 12 (2 x 6 outputs) | ... | ... |
Support: | ... | DAHUA | ... |
Number of power inputs: | 2 (one per each 6-outputs terminal) | ... | ... |
Number of supported readers: | ... | 4 pcs | ... |
Maximal power voltage: | 24 V DC (typical 12V) | ... | ... |
Inputs: | ... | ... | 8 pcs - Mainboard inputs max. 32 |
Maximal power supply current: | 5 A (for single terminal) | ... | ... |
Output lines: | ... | 2 pcs - Relay | ... |
Max. output current for single output: | 1 A | ... | ... |
Protection type: | 12 x 1 A 5/20mm delayed fuse | ... | ... |
Outputs: | ... | ... | 4 pcs - Transistor outputs 2 pcs - Relay outputs NO/NC |
Communication: | ... | RS-485, Ethernet, Wiegand | RS-485, RACS (Roger) |
Power connectors type: | Input : Cable terminals Output : Cable terminals | ... | ... |
Events memory: | ... | ... | Non-volatile log buffer of the last 250 000 events |
Housing type: | RACK 19", 1U | ... | ... |
Default IP address: | ... | 192.168.0.2 | ... |
Output load: | ... | ... | Transistor outputs : 1 A / 15 V DC Relay outputs : REL1 - 1.5 A / 30 V DC REL2 - 5 A / 230 V AC |
Default admin user / password: | ... | admin / - The administrator password should be set at the first start | ... |
Main features: | ... | 100000 indexed users History of 500000 events Remote programming from PC Function of protection against multiple use of the same card for access (anti-passback) Counter of the door opening time with the possibility of sending an alarm signal after exceeding the set value Automatic sending of alarm messages to the SmartPSS system or after entering a code, card or fingerprint defined as door opening under duress Possibility to mount on a wall, or on the DIN TS-35 rail | Ability to block/unblock partition at a specified time, or as per access schedule, Central management of the access control system, Integration with the alarm system SATEL INTEGRA, History of 250 000 events Electrical protection of all inputs and outputs as well as communication buses DIN, TS-35 rail mounting |
Power supply: | ... | PoE (802.3at), 12 V DC / 4 A | 24 V DC 12 V DC 18 V AC |
Battery backup support: | ... | | |
Operation temp: | -50 °C ... 55 °C | -30 °C ... 60 °C | 5 °C ... 40 °C |
Permissible relative humidity: | < 95 % | 5 % ... 90 % (non-condensing) | 10 % ... 95 % (non-condensing) |
Dimensions: | 482 x 45 x 39 mm | 155 x 116 x 50 mm | 105 x 85 x 50 mm |
Weight: | 0.3 kg | 0.27 kg | 0.12 kg |
Manufacturer / Brand: | DELTA | DAHUA | ROGER |
Guarantee: | 3 years | 3 years | 3 years |