![](img/compere_shop_all.png) - Show All ![](img/compere_shop_identical.png) - Show differences - Back | ![](img/eclose_grey.png) POWER DISTRIBUTION UNIT L19/6VP | ![](img/eclose_grey.png) UNIVERSAL METER UT-191T UNI-T |
| ![L19/6VP Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/l19_6vp_v3_m.jpg) | ![UT-191T Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/ut-191t_m.jpg) |
| 19.62 EUR 19.62 EUR
| 70.54 EUR 70.54 EUR
|
Rated voltage: | 230 V AC / 50 Hz | ... |
Total maximal current: | 16 A | ... |
Maximal total load: | 3500 W | ... |
Number of outlets: | 6 for universal plug 230 V (Schuko) | ... |
Assembly: | In RACK 19" cabinets | ... |
Length of the power cable: | 1.8 m | ... |
Housing type: | 1 U RACK 19" | ... |
Switch: | Yes (with built-in LED indicator) | ... |
DC voltage measurement: | ... | 600 mV ± (0.7% + 3) @ 0.1 mV , 6 V ± (0.5% + 3) @ 0.001 V , 60 V ± (0.7% + 3) @ 0.01 V , 600 V ± (0.7% + 3) @ 0.1 V |
AC voltage measurement: | ... | 600 mV ± (1.0% + 4) @ 0.1 mV , 6 V ± (0.7% + 3) @ 0.001 V , 60 V ± (1.0% + 3) @ 0.01 V , 600 V ± (1.0% + 3) @ 0.1 V LPF mode : 600 V ± (2.0% + 5) @ 0.1 V LoZ mode : 600 V ± (2.0% + 5) @ 0.1 V |
DC current measurement: | ... | 600 µA ± (0.8% + 3) @ 0.1 µA , 6000 µA ± (0.8% + 3) @ 1 µA , 60 mA ± (0.8% + 3) @ 0.01 mA , 600 mA ± (0.8% + 3) @ 0.1 mA , 6 A ± (1.0% + 3) @ 0.001 A , 20 A ± (1.2% + 5) @ 0.01 A |
AC current measurement: | ... | 600 µA ± (1.0% + 3) @ 0.1 µA , 6000 µA ± (1.0% + 3) @ 1 µA , 60 mA ± (1.0% + 3) @ 0.01 mA , 600 mA ± (1.0% + 3) @ 0.1 mA , 6 A ± (1.2% + 3) @ 0.001 A , 20 A ± (1.5% + 5) @ 0.01 A |
Resistance measurement: | ... | 600 Ω ± (1.0% + 2) @ 0.1 Ω , 6 kΩ ± (0.8% + 2) @ 0.001 kΩ , 60 kΩ ± (0.8% + 2) @ 0.01 kΩ , 600 kΩ ± (0.8% + 2) @ 0.1 kΩ , 6 MΩ ± (1.2% + 3) @ 0.001 MΩ , 60 MΩ ± (2.5% + 5) @ 0.01 MΩ |
Capacitance measurement: | ... | 6 nF ± (4% + 8) + capacity of test leads @ 1 pF , 60 nF ... 600 µF ± (3% + 5) @ 10 pF ... 100 nF , 6 mF ... 60 mF ± 10% @ 1 µF ... 10 µF |
Inductance measurement: | ... | |
Frequency measurement: | ... | 10 Hz ... 1 MHz ± (0.1% + 4) @ 0.01 Hz ... 0.001 MHz |
Square-wave signal duty ratio measurement: | ... | 0.1 % ... 99.9 % ± (2% + 5) @ 0.1 % |
Temperature measurement: | ... | °C -40 ... 400 °C ± (1% + 2°C) @ 0.1 °C ... 1 °C , °F -40 ... 752 °F ± (1% + 4°F) @ 0.2 °F ... 2 °F |
Automatic change of measuring ranges: | ... | |
hFE: | ... | |
Diode test: | ... | |
Sound signal of the continuity test: | ... | |
Checking TTL logic states: | ... | |
RS-232: | ... | |
USB: | ... | |
Main features: | Overvoltage protection LED indicators displaying the device's operating status | True RMS - accurate measurement of the RMS current and voltage for any waveform, Possibility to measure AC voltage using low measuring impedance (LoZ mode), LPF function - allows to measure the AC voltage values using low-pass filter with a frequency limit of 200 Hz, Robust housing that meets the requirements of the IP65 "Index of Protection" class, Freezing the last reading, Flashlight built-in, Freezing the highest or lowest measurement, REL - relative measurement mode, Analog bargraph, Large, readable LCD display with backlight, Low battery level alarm, Aesthetic and solid construction, The set includes a practical case |
Power supply: | ... | 9V, type 6LR61 battery |
Weight: | 0.75 kg | 0.4 kg |
Dimensions: | 482 x 45 x 54 mm | 180 x 87 x 66 mm |
Manufacturer / Brand: | ... | UNI-T |
Guarantee: | 2 years | 2 years |