HANGING RACK CABINET EPRADO-R19-15U/600-BLUE


WIRELESS DOOR CHIME ATLO-DBC5/CHIME


MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-595 UNI-T

130.07 EUR
130.07 EUR

8.82 EUR
8.82 EUR

574.07 EUR
574.07 EUR

Signaling mode:  ...  Optical - sound signaling  ...  
Internal width:  19 "  ...  ...  
Number of ring-tones:  ...  64   ...  
Internal height:  15 U  ...  ...  
Internal depth:  545 mm  ...  ...  
Volume adjustment:  ...  4 volume levels, with Mute function  ...  
External width:  600 mm  ...  ...  
Operation range:  ...  300 m in open area  ...  
External height:  770 mm  ...  ...  
External depth:  600 mm  ...  ...  
Frequency band:  ...  433 MHz ± 0.075   ...  
Holes for fan coolers:  105  x 105 mm (2 places)  ...  ...  
Bearing capacity:  60 kg  ...  ...  
Door:  
  • Front: glass
  • Side: metal, snap-in  
  • ...  ...  
    Power consumption:  ...  ≤ 27.6 W (operation)
    ≤ 2.3 W (Standby mode)  
    ...  
    Resistance measurement:  ...  ...  
  • Test voltage 250 V : 0.05 MΩ ... 250 MΩ
  • Test voltage 500 V : 0.05 MΩ ... 500 MΩ
  • Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ  
  • Measuring accuracy:  ...  ...  0.05 MΩ ... 1000 MΩ ± (5% + 5)   
    Housing:  ...  Plastic  ...  
    Color:  Black RAL9004  Black  ...  
    Open circuit voltage:  ...  ...  Test voltage ± 10 %  
    Test current:  ...  ...  0.9 mA ... 1.1 mA  
    Short-circuit current:  ...  ...  < 1.8 mA  
    AC voltage measurement:  ...  ...  0 V ... 440 V ± (2% + 3)  @ 1 V  
    DC voltage measurement:  ...  ...  0 V ... ± 440 V ± (2% + 3)  @ 1 V  
    Measurement of small resistances:  ...  ...  0.01 Ω ... 200 Ω ± (2% + 5)   
    Frequency measurement:  ...  ...  20 Hz ... 100 Hz - for reference only  
    Test of RCDs:  ...  ...  
  • Working voltage: 220V ± 10 %
  • Test current: 10mA / 30mA / 100mA / 300mA / 500mA
  • Switch-off time ranges :
    • 0 ... 2000 ms ± (5% + 5)  @ 1/2 x nominal value of the residual current
    • 0 ... 500 ms ± (5% + 5)  @ 1 x  nominal value of the residual current, Selective RCD
    • 0 ... 500 ms ± (5% + 5)  @ 2 x nominal value of the residual current, Selective RCD
    • 0 ... 300 ms ± (5% + 5)  @ 1 x nominal value of the residual current
    • 0 ... 300 ms ± (5% + 5)  @ 2 x nominal value of the residual current
    • 0 ... 40 ms ± (5% + 5)  @ 5 x nominal value of the residual current
     
  • RCD tripping current measurement:  ...  ...  
    Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 %  
    RCD automatic test:  ...  ...    
    Phase sequence test:  ...  ...  100 V ... 440 V / 45 Hz ... 65 Hz  
    Continuity measurement of protective and equalizing conductors:  ...  ...  0 Ω ... 199 Ω ± (2% + 5) 
    Measuring current > 20 mA @ 0 ... 2 Ω  
    Line impedance measurement (L-N):  ...  ...  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    Short circuit loop impedance measurement (L-PE):  ...  ...  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    Automatic change of measuring ranges:  ...  ...    
    RS-232:  ...  ...    
    USB:  ...  ...    
    Main features:  
  • Cable entries are placed from the top and bottom
  • Removable side panels
  • Possibility to unscrew the rear panel
  • Possibility to mount the door as left or right
  • Mounting rail spacing : 490 mm
  • 2 keys included
  • Rack rails to mounting the devices - 4 pcs  
  • Support : ATLO
  • Low power consumption
  • Simple and quick device installation  
  • Warning of using high voltage during the measurement,
  • Phase switch 0° / 180° during RCD test,
  • Automatic identification of AC/DC voltage,
  • Reset function for measuring low resistances,
  • Large, readable LCD display with backlight,
  • Buzzer,
  • Automatic power-off,
  • Low battery indicator,
  • Aesthetic and solid construction  
  • Operation temp:  ...  -30 °C ... 70 °C  0 °C ... 40 °C  
    Permissible relative humidity:  ...  ...  ≤ 85 % (non-condensing)  
    Power supply:  ...  90  ... 250 V AC @ 50  / 60 Hz  8 x 1.5V, type AA/LR6/FR6 battery - included  
    Weight:  29.5 kg  0.052 kg  1.1 kg  
    Dimensions:  ...  84  x 52  x 56 mm  210  x 175  x 90 mm  
    Manufacturer / Brand:  EPRADO  ATLO  UNI-T  
    Guarantee:  3 years  2 years  2 years