- Show All - Show differences - Back | AHD, HD-CVI, HD-TVI, CVBS, TCP/IP DVR IDS-E04HQHI-B 4 CHANNELS ACUSENSE Hikvision | DIGITAL MULTIMETER MM-UA9233D UYIGAO |
| | |
| 240.91 EUR 240.91 EUR
| 9.96 EUR 9.96 EUR
|
Standard: | AHD, HD-CVI, HD-TVI, CVBS, TCP/IP | ... |
Video inputs: | 4 pcs BNC - AHD / HD-CVI / HD-TVI / CVBS | ... |
Video outputs: | 1 pcs HDMI 1 pcs VGA | ... |
Audio inputs: | 4 - Audio support via coaxial cable | ... |
DC voltage measurement: | ... | 2 V ± (0.5%) @ 0.001 V , 20 V ± (0.5%) @ 0.01 V , 200 V ± (0.8%) @ 0.1 V , 600 V ± (0.8%) @ 1 V |
Audio outputs: | | ... |
Image compression method: | H.265+ / H.265 | ... |
AC voltage measurement: | ... | 2 V ± (0.8%) @ 0.001 V , 20 V ± (0.8%) @ 0.01 V , 200 V ± (1.0%) @ 0.1 V , 600 V ± (1.0%) @ 1 V |
Image records resolutions: | HD-TVI / HD-CVI / AHD : 4M-N - 1280 x 1440 , 1080p - 1920 x 1080 , 1080N - 960 x 1080 , 720p - 1280 x 720 , CVBS : 960H - 960 x 576 , IP : max. 6 Mpx - 3072 x 2048 | ... |
DC current measurement: | ... | 200 µA ± (1.0% + 5) @ 0.1 µA , 2000 µA ± (1.0% + 5) @ 1 µA , 20 mA ± (1.0% + 5) @ 0.01 mA , 200 mA ± (1.0% + 5) @ 0.1 mA , 2 A ± (2.0% + 10) @ 0.001 A , 10 A ± (2.0% + 10) @ 0.01 A |
Recording speed adjustment: | 6 Mpx IP @ 1 ... 25 fps 4M-N @ 1 ... 15 fps 1080p @ 1 ... 15 fps 1080N @ 1 ... 25 fps 720p @ 1 ... 25 fps 960H @ 1 ... 25 fps for each channel | ... |
Operation modes: | 4 x HD-TVI / AHD / HD-CVI / PAL + 1 x IP | ... |
Recording modes: | Manual, Motion Detection, Schedule | ... |
Supported hard drives: | 1 x 512 GB eSSD - Built-in, Space available for records : 480 GB | ... |
External storage devices backup: | Backup to USB drive (pendrive, external drive) | ... |
Searching and playback the records: | Records searching: timeline or file list. Playback: forward, fast, slow. Playback max. 4 cameras in the same time | ... |
Network interface: | 1 x RJ-45 - 10/100 Base-T | ... |
Network functions: | Network Client Software and IE browser: live view, playback and backup of the records, partial configuration of the recorder parameters | ... |
AC current measurement: | ... | 200 µA ± (1.5%) @ 0.1 µA , 2000 µA ± (1.5%) @ 1 µA , 20 mA ± (1.5%) @ 0.01 mA , 200 mA ± (1.5%) @ 0.1 mA , 2 A ± (2.5%) @ 0.001 A , 10 A ± (2.5%) @ 0.01 A |
Network protocols: | TCP/IP, DHCP, Hik-Connect, DNS, DDNS, NTP, SADP, SMTP, NFS, UPnP, HTTPS | ... |
Mobile phones support: | Port no.: 8000 or access by a cloud (P2P) Android: Free application Hik-Connect iOS (iPhone): Free application Hik-Connect | ... |
Default IP address: | DHCP or 192.168.1.64 | ... |
Default admin user / password: | admin / - | ... |
Web browser access ports: | 80 | ... |
PC client access ports: | 554 RTSP, 8000 | ... |
Mobile client access ports: | 8000 | ... |
Port ONVIF: | 80 | ... |
Resistance measurement: | ... | 200 Ω ± (0.8%) @ 0.1 Ω , 2 kΩ ± (0.8%) @ 0.001 kΩ , 20 kΩ ± (0.8%) @ 0.01 kΩ , 200 kΩ ± (0.8%) @ 0.1 kΩ , 2 MΩ ± (1.2%) @ 0.001 MΩ , 20 MΩ ± (1.2%) @ 0.01 MΩ |
RTSP URL: | rtsp://user:password@192.168.1.64:554/Streaming/Channels/channel_no01/ - Main stream rtsp://user:password@192.168.1.64:554/Streaming/Channels/channel_no02/ - Sub stream | ... |
Alarm inputs / outputs: | | ... |
PTZ control: | Control compatible with coax HD-TVI Hikvision | ... |
Motion Detection: | 2.0 | ... |
Main features: | DVR from the AcuSense series Intelligent image analysis : intrusion, crossing the line (tripwire), Deep Learning technology Smart motion detection (with recognizing people and vehicles) Filtering of false alarms based on the recognition of persons and vehicles | ... |
USB: | 2 pcs USB 2.0 | ... |
Mouse support: | | ... |
IR remote controller in the set: | | ... |
Color: | Black | ... |
Capacitance measurement: | ... | 9.999 nF ± (4%) @ 0.001 nF , 99.99 nF ± (4%) @ 0.01 nF , 999.9 nF ± (4%) @ 0.1 nF , 9.999 µF ± (4%) @ 0.001 µF , 99.99 µF ± (4%) @ 0.01 µF , 999.9 µF ± (4%) @ 0.1 µF , 9.999 mF ± (5%) @ 0.001 mF , 99.99 mF @ 0.01 mF - visual measurement |
Inductance measurement: | ... | |
Frequency measurement: | ... | 9.999 Hz ... 9.999 MHz ± (1%) @ 0.001 Hz ... 0.001 MHz |
Square-wave signal duty ratio measurement: | ... | 0.1 ... 99.9 % ± (3.0%rd) @ 0.1 % |
Supported languages: | Polish, English, Bulgarian, Croatian, Czech, Danish, Estonian, Greek, Spanish, Dutch, German, Norwegian, Portuguese, Russian, Romanian, Serbian, Slovak, Slovenian, Swedish, Turkish, Hungarian, Italian | ... |
SAP Code: | 300228637 | ... |
Temperature measurement: | ... | °C : -20 ... 300 °C ± (1.0%) @ 1 °C , 301 ... 1000 °C ± (1.9%) @ 1 °C , °F :
-4 ... 600 °F ± (1.2%) @ 1 °F , 601 ... 1832 °F ± (1.9%) @ 1 °F |
hFE: | ... | |
Diode test: | ... | |
Sound signal of the continuity test: | ... | |
Checking TTL logic states: | ... | |
RS-232: | ... | |
Main features: | ... | Large, readable LCD display with backlight Hold - stopping the meter reading NCV - electric field detection function Built-in LED flashlight Aesthetic and solid construction |
Power supply: | 12 V DC / 1 A (power adapter included) | 9V, type 6F22 battery (not included) |
Weight: | 0.42 kg | 0.2 kg |
Dimensions: | 152 x 122 x 46 mm | 68 x 147 x 48 mm |
Manufacturer / Brand: | Hikvision | UYIGAO |
Guarantee: | 3 years | 2 years |