![](img/compere_shop_all.png) - Show All ![](img/compere_shop_identical.png) - Show differences - Back | ![](img/eclose_grey.png) DEVELOPMENT KIT ESP32-ESP-WROOM-32 Espressif | ![](img/eclose_grey.png) REMOTE CONTROL FOR LED LIGHTING CONTROLLERS LED-CONTROL-W/RF 2.4 GHz, MONO, CCT MiBOXER / Mi-Light | ![](img/eclose_grey.png) UPS VI-1500/R1U 1500 VA PowerWalker | ![](img/eclose_grey.png) TIME RELAY MODULE AWZ-526 | ![](img/eclose_grey.png) MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-595 UNI-T |
| ![ESP32-ESP-WROOM-32 Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/esp32-esp-wroom-32_m.jpg) | ![LED-CONTROL-W/RF Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/led-control-w_rf_m.jpg) | ![VI-1500/R1U Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/vi-1500_r1u_m.jpg) | ![AWZ-526 Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/awz-526_m.jpg) | ![UT-595 Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/ut-595_m.jpg) |
| 8.91 EUR 8.91 EUR
| 7.53 EUR 7.53 EUR
| 532.45 EUR 532.45 EUR
| 14.93 EUR 14.93 EUR
| 567.49 EUR 567.49 EUR
|
Nominal power: | ... | ... | 900 W | ... | ... |
Number of relay outputs: | ... | ... | ... | 1 | ... |
Apparent Power: | ... | ... | 1500 VA | ... | ... |
Supported standards: | IEEE 802.11 b/g/n, Bluetooth LE | ... | ... | ... | ... |
Processor: | Xtensa® 32-bit LX6 | ... | ... | ... | ... |
Input voltage: | ... | ... | 165 ... 290 V AC | ... | ... |
Application: | ... | Works with LED lighting : single-color (MONO) 12-24V LED strips, white LED strips with adjustable color temperature (CCT) 12-24V | ... | ... | ... |
Supported transmission speeds: | max. 150 Mbps | ... | ... | ... | ... |
Current consumption: | ... | ... | ... | 35 mA (max) | ... |
Number of channels: | ... | 4 | ... | ... | ... |
Input frequency: | ... | ... | 45 ... 55 Hz | ... | ... |
Wireless: | ... | 2.4 GHz | ... | ... | ... |
Radio communication range (at open area): | ... | 30 m | ... | ... | ... |
Relay maximal load: | ... | ... | ... | 1 A (max) @ 30 V DC / 50 V AC (max) | ... |
Output voltage: | ... | ... | 230 V AC (Pure Sine Wave) | ... | ... |
Operation modes: | Station / Soft AP / Station + Soft AP | ... | ... | ... | ... |
Output: | ... | ... | ... | 1 x NO/NC | ... |
Output frequency: | ... | ... | 50 Hz | ... | ... |
Antenna type: | Indoor | ... | ... | ... | ... |
Voltage adjustment: | ... | ... | ± 10 % | ... | ... |
Frequency adjustment: | ... | ... | | ... | ... |
Housing: | ... | Plastic | ... | ... | ... |
Transfer time: | ... | ... | max. 4 ms | ... | ... |
Charging time (recover to 90% capacity): | ... | ... | 8 hours | ... | ... |
Color: | ... | White | ... | ... | ... |
Battery: | ... | ... | 4 x 6V/9Ah | ... | ... |
Resistance measurement: | ... | ... | ... | ... | Test voltage 250 V : 0.05 MΩ ... 250 MΩ Test voltage 500 V : 0.05 MΩ ... 500 MΩ Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ |
Measuring accuracy: | ... | ... | ... | ... | 0.05 MΩ ... 1000 MΩ ± (5% + 5) |
Estimated battery operation time: | ... | ... | 3.1 minutes @ 100% load 12.1 minutes @ 50% load | ... | ... |
Open circuit voltage: | ... | ... | ... | ... | Test voltage ± 10 % |
Number of outputs: | ... | ... | 4 pcs IEC320 C13 socket | ... | ... |
Interface: | micro USB, UART 3.3 V, SDIO, SPI, I2C, I2S, GPIO, ADC, DAC, PWM, TWAI®, RMT | ... | ... | ... | ... |
Management software: | ... | ... | PowerMaster | ... | ... |
Frequency range: | 2.4 GHz | ... | ... | ... | ... |
Test current: | ... | ... | ... | ... | 0.9 mA ... 1.1 mA |
Short-circuit current: | ... | ... | ... | ... | < 1.8 mA |
Protections: | ... | ... | Fuse Overvoltage Overload protection EPO (Emergency power off) switch | ... | ... |
AC voltage measurement: | ... | ... | ... | ... | 0 V ... 440 V ± (2% + 3) @ 1 V |
Operation state indication: | ... | ... | LCD display: operation mode, battery charging level, in/out voltage level Sound signaling - with Mute function | ... | ... |
DC voltage measurement: | ... | ... | ... | ... | 0 V ... ± 440 V ± (2% + 3) @ 1 V |
Measurement of small resistances: | ... | ... | ... | ... | 0.01 Ω ... 200 Ω ± (2% + 5) |
Receiver sensitivity: | 11b 11M : -88 dBm 11g 54M : -75 dBm 11n HT20 MCS0 : -93 dBm 11n HT20 MCS7 : -70 dBm 11n HT40 MCS0 : -90 dBm 11n HT40 MCS7 : -70 dBm Bluetooth : -94 dBm | ... | ... | ... | ... |
Frequency measurement: | ... | ... | ... | ... | 20 Hz ... 100 Hz - for reference only |
Application: | ... | ... | Surveillance Systems data storage centers network, servers, workstations Industrial Equipment | ... | ... |
Housing type: | ... | ... | RACK | ... | ... |
Security measures: | WEP / TKIP / AES, Hash (SHA-2), RSA, ECC | ... | ... | ... | ... |
Operation temp. / Relative humidity: | ... | ... | 0 °C ... 40 °C / 0 ... 90 % (non-condensing) | ... | ... |
Test of RCDs: | ... | ... | ... | ... | Working voltage: 220V ± 10 % Test current: 10mA / 30mA / 100mA / 300mA / 500mA Switch-off time ranges :
- 0 ... 2000 ms ± (5% + 5) @ 1/2 x nominal value of the residual current
- 0 ... 500 ms ± (5% + 5) @ 1 x nominal value of the residual current, Selective RCD
- 0 ... 500 ms ± (5% + 5) @ 2 x nominal value of the residual current, Selective RCD
- 0 ... 300 ms ± (5% + 5) @ 1 x nominal value of the residual current
- 0 ... 300 ms ± (5% + 5) @ 2 x nominal value of the residual current
- 0 ... 40 ms ± (5% + 5) @ 5 x nominal value of the residual current
|
RCD tripping current measurement: | ... | ... | ... | ... | Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 % |
RCD automatic test: | ... | ... | ... | ... | |
Phase sequence test: | ... | ... | ... | ... | 100 V ... 440 V / 45 Hz ... 65 Hz |
Continuity measurement of protective and equalizing conductors: | ... | ... | ... | ... | 0 Ω ... 199 Ω ± (2% + 5) Measuring current > 20 mA @ 0 ... 2 Ω |
Line impedance measurement (L-N): | ... | ... | ... | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA |
Short circuit loop impedance measurement (L-PE): | ... | ... | ... | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA |
Automatic change of measuring ranges: | ... | ... | ... | ... | |
RS-232: | ... | ... | ... | ... | |
USB: | ... | ... | ... | ... | |
Main features: | Built-in USB -> UART interface (chip CP2102) Buttons for operating the device in programming mode | Large, readable buttons | Auto restart while AC is recovering "Cold Start" function Expansion slot Battery charge and maintenance control USB/RS-232 communication port | Time settings range 1. Range : 1 s ... 60 s , 2. Range : 5 s ... 5 minutes LED indication | Warning of using high voltage during the measurement, Phase switch 0° / 180° during RCD test, Automatic identification of AC/DC voltage, Reset function for measuring low resistances, Large, readable LCD display with backlight, Buzzer, Automatic power-off, Low battery indicator, Aesthetic and solid construction |
Operation temp: | -40 °C ... 85 °C | -20 °C ... 60 °C | ... | -10 °C ... 40 °C | 0 °C ... 40 °C |
Permissible relative humidity: | ... | ... | ... | ... | ≤ 85 % (non-condensing) |
Power supply: | ... | 2 x 1.5V, type AAA/LR03 battery (not included) | ... | 10 ... 14 V DC | 8 x 1.5V, type AA/LR6/FR6 battery - included |
Weight: | 0.01 kg | 0.044 kg (without battery) | 16.31 kg | 0.035 kg | 1.1 kg |
Dimensions: | 55 x 29 x 13 mm | 110 x 53 x 21 mm | 435 x 400 x 44 mm ; RACK 19", 1U | 69 x 43 x 22 mm | 210 x 175 x 90 mm |
Manufacturer / Brand: | Espressif | MiBOXER / Mi-Light | PowerWalker | PULSAR | UNI-T |
Guarantee: | 2 years | 2 years | 2 years | 2 years | 2 years |