- Show All - Show differences - Back | MONITOR VGA, HDMI VM-2701 27 " VILUX | MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-593 UNI-T |
| | |
| 124.37 EUR 124.37 EUR
| 457.98 EUR 457.98 EUR
|
Screen size: | 27 " | ... |
Native resolution: | 1920 x 1080 px | ... |
Aspect ratios: | 16 : 9 | ... |
Matrix type: | MVA, LED backlight, Matte matrix | ... |
Contrast: | 2000 : 1 (typical) | ... |
Brightness: | 300 cd/m2 | ... |
Viewable angles: | 176 ° horizontal, 176 ° vertical | ... |
Response time: | 3 ms | ... |
Number of displayed colors: | 16.7 M | ... |
Refresh frequency: | max. 75 Hz | ... |
Speakers built-in: | | ... |
Resistance measurement: | ... | Test voltage 250 V : 0.05 MΩ ... 250 MΩ Test voltage 500 V : 0.05 MΩ ... 500 MΩ Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ |
Measuring accuracy: | ... | 0.05 MΩ ... 1000 MΩ ± (5% + 5) |
Open circuit voltage: | ... | Test voltage ± 10 % |
Signal connectors: | 1 x VGA, 1 x HDMI, 1 x 2.1/5.5 mm socket - Power connector | ... |
Test current: | ... | 0.9 mA ... 1.1 mA |
Short-circuit current: | ... | < 1.8 mA |
AC voltage measurement: | ... | 0 V ... 440 V ± (2% + 3) @ 1 V |
Housing type: | Plastic, Narrow profile | ... |
Power management: | Energy efficiency class A+ (Regulation (EU) 2019/2015) | ... |
DLNA: | | ... |
Monitor mounting standard: | VESA 100 | ... |
Robbery protection: | | ... |
DC voltage measurement: | ... | 0 V ... ± 440 V ± (2% + 3) @ 1 V |
Parameters adjustment: | OSD - using the button on the casing | ... |
Designed to continuous operation 24/7: | | ... |
Measurement of small resistances: | ... | 0.01 Ω ... 200 Ω ± (2% + 5) |
Frequency measurement: | ... | 20 Hz ... 100 Hz - for reference only |
Power consumption: | ≤ 22 W (typical) ≤ 0.3 W (in standby mode) | ... |
Test of RCDs: | ... | Working voltage: 220V ± 10 % Test current: 10mA / 30mA / 100mA / 300mA / 500mA Switch-off time ranges :
- 0 ... 2000 ms ± (5% + 5) @ 1/2 x nominal value of the residual current
- 0 ... 500 ms ± (5% + 5) @ 1 x nominal value of the residual current, Selective RCD
- 0 ... 300 ms ± (5% + 5) @ 1 x nominal value of the residual current
- 0 ... 40 ms ± (5% + 5) @ 5 x nominal value of the residual current
|
RCD tripping current measurement: | ... | Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 % |
RCD automatic test: | ... | |
Phase sequence test: | ... | 100 V ... 440 V / 45 Hz ... 65 Hz |
Continuity measurement of protective and equalizing conductors: | ... | 0 Ω ... 199 Ω ± (2% + 5) Measuring current > 20 mA @ 0 ... 2 Ω |
Line impedance measurement (L-N): | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA |
Short circuit loop impedance measurement (L-PE): | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA |
Automatic change of measuring ranges: | ... | |
RS-232: | ... | |
USB: | ... | |
Main features: | Flicker-free - The technology eliminates the tiring eyes flickering image effect The blue light reduction function, which is the most unhealthy for the eyes, limits its emission HDMI cable included | Warning of using high voltage during the measurement, Phase switch 0° / 180° during RCD test, Automatic identification of AC/DC voltage, Reset function for measuring low resistances, Large, readable LCD display with backlight, Buzzer, Automatic power-off, Low battery indicator, Aesthetic and solid construction |
Operation temp: | ... | 0 °C ... 40 °C |
Permissible relative humidity: | ... | ≤ 85 % (non-condensing) |
Power supply: | 12 V DC / 3 A (power adapter included) | 8 x 1.5V, type AA/LR6/FR6 battery - included |
Weight: | 3.28 kg (with stand) | 1.1 kg |
Dimensions: | 613 x 363 x 220 mm (with stand) 613 x 363 x 38 (without stand) | 210 x 175 x 90 mm |
Manufacturer / Brand: | VILUX | UNI-T |
Guarantee: | 2 years | 2 years |