- Show All - Show differences - Back | SOFTWARE RCPM4-WEB-2000 ROGER | MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-595 UNI-T |
| | |
| 4085.62 EUR 4085.62 EUR
| 577.05 EUR 577.05 EUR
|
License: | RCP Master 4 Web | ... |
Number of employees: | max. 2000 | ... |
Time range: | 12 months | ... |
Main features: | Overview of the working time Remote registration of T&A events Employee work history Registration of remote work Submitting holiday requests and other types of absence Verifying of the holiday usage Displaying the current status of the attendance of employees (present, absent, on a business trip, etc.) Graphical visualization of employee attendance (attendance list) | ... |
Operation: | Web browser | ... |
Supported languages: | English, Polish | ... |
Resistance measurement: | ... | Test voltage 250 V : 0.05 MΩ ... 250 MΩ Test voltage 500 V : 0.05 MΩ ... 500 MΩ Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ |
Measuring accuracy: | ... | 0.05 MΩ ... 1000 MΩ ± (5% + 5) |
Open circuit voltage: | ... | Test voltage ± 10 % |
Test current: | ... | 0.9 mA ... 1.1 mA |
Short-circuit current: | ... | < 1.8 mA |
AC voltage measurement: | ... | 0 V ... 440 V ± (2% + 3) @ 1 V |
DC voltage measurement: | ... | 0 V ... ± 440 V ± (2% + 3) @ 1 V |
Measurement of small resistances: | ... | 0.01 Ω ... 200 Ω ± (2% + 5) |
Frequency measurement: | ... | 20 Hz ... 100 Hz - for reference only |
Test of RCDs: | ... | Working voltage: 220V ± 10 % Test current: 10mA / 30mA / 100mA / 300mA / 500mA Switch-off time ranges :
- 0 ... 2000 ms ± (5% + 5) @ 1/2 x nominal value of the residual current
- 0 ... 500 ms ± (5% + 5) @ 1 x nominal value of the residual current, Selective RCD
- 0 ... 500 ms ± (5% + 5) @ 2 x nominal value of the residual current, Selective RCD
- 0 ... 300 ms ± (5% + 5) @ 1 x nominal value of the residual current
- 0 ... 300 ms ± (5% + 5) @ 2 x nominal value of the residual current
- 0 ... 40 ms ± (5% + 5) @ 5 x nominal value of the residual current
|
RCD tripping current measurement: | ... | Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 % |
RCD automatic test: | ... | |
Phase sequence test: | ... | 100 V ... 440 V / 45 Hz ... 65 Hz |
Continuity measurement of protective and equalizing conductors: | ... | 0 Ω ... 199 Ω ± (2% + 5) Measuring current > 20 mA @ 0 ... 2 Ω |
Line impedance measurement (L-N): | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA |
Short circuit loop impedance measurement (L-PE): | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA |
Automatic change of measuring ranges: | ... | |
RS-232: | ... | |
USB: | ... | |
Main features: | ... | Warning of using high voltage during the measurement, Phase switch 0° / 180° during RCD test, Automatic identification of AC/DC voltage, Reset function for measuring low resistances, Large, readable LCD display with backlight, Buzzer, Automatic power-off, Low battery indicator, Aesthetic and solid construction |
Operation temp: | ... | 0 °C ... 40 °C |
Permissible relative humidity: | ... | ≤ 85 % (non-condensing) |
Power supply: | ... | 8 x 1.5V, type AA/LR6/FR6 battery - included |
Weight: | ... | 1.1 kg |
Dimensions: | ... | 210 x 175 x 90 mm |
Manufacturer / Brand: | ROGER | UNI-T |
Guarantee: | ... | 2 years |