COMBINATION WRENCH ST-STMT95912-0 19 mm STANLEY


LABORATORY METER UT-801 UNI-T


GRAPHIC KEYPAD FOR ALARM CONTROL PANEL INT-TSG2-B SATEL

4.41 EUR
4.41 EUR

104.10 EUR
104.10 EUR

252.16 EUR
252.16 EUR

Size:  19 mm  ...  ...  
Length:  231 mm  ...  ...  
Support:  ...  ...  INTEGRA, INTEGRA Plus, VERSA  
DC voltage measurement:  ...  
  • 200 mV ± (0.5% + 2)  @ 0.1 mV,
  • 2 V ± (0.5% + 2)  @ 1 mV,
  • 20 V ± (0.5% + 2)  @ 10 mV,
  • 200 V ± (0.5% + 2)  @ 100 mV,
  • 1000 V ± (0.8% + 3)  @ 1 V  
  • ...  
    Main features:  ...  ...  
  • Large, easily readable LCD with backlight displaying detailed information on system state
  • 4.3 " capacitive touch screen 480 x 272 px
  • Clear graphical interface
  • LED indicators displaying the device's operating status
  • 2 Inputs - INTEGRA, INTEGRA Plus only
  • EOL, 2EOL, 3EOL configurations support
  • MAKRO features that activates sequence of actions with a single key
  • easy operation of the multi-zone systems
  • Alarms: keypad hold-down PANIC, FIRE and AUX
  • Bbuzzer for acoustic signaling of some system events
  • Panel communication loss indication
  • Tamper detection - opening the enclosure, removing from mounting surface
  • Memory card slot - microSD
  • Screen saver with calendar/clock and or photo frame function  
  • Current consumption:  ...  ...  max. 140 mA  
    Color:  ...  ...  Black  
    Operation temp:  ...  ...  -10 °C ... 55 °C  
    AC voltage measurement:  ...  
  • 2 V ± (0.8% + 3)  @ 1 mV,
  • 20 V ± (1.0% + 4)  @ 10 mV,
  • 200 V ± (1.0% + 4)  @ 100 mV,
  • 1000 V ± (1.0% + 4)  @ 1 V  
  • ...  
    DC current measurement:  ...  
  • 200 µA ± (0.8% + 2)  @ 0.1 µA,
  • 2 mA ± (0.8% + 2)  @ 0.001 mA,
  • 20 mA ± (0.8% + 2)  @ 0.01 mA,
  • 200 mA ± (0.8% + 2)  @ 0.1 mA,
  • 10 A ± (2.0% + 4)  @ 0.01 A  
  • ...  
    AC current measurement:  ...  
  • 2 mA ± (1.0% + 3)  @ 0.001 mA,
  • 20 mA ± (1.0% + 3)  @ 0.01 mA,
  • 200 mA ± (1.0% + 3)  @ 0.1 mA,
  • 10 A ± (2.5% + 5)  @ 0.01 A  
  • ...  
    Resistance measurement:  ...  
  • 200 Ω ± (0.8% + 3)  @ 0.1 Ω,
  • 2 kΩ ± (0.8% + 3)  @ 1 Ω,
  • 20 kΩ ± (0.8% + 3)  @ 10 Ω,
  • 200 kΩ ± (0.8% + 3)  @ 100 Ω,
  • 2 MΩ ± (0.8% + 3)  @ 1 kΩ,
  • 20 MΩ ± (1.2% + 5)  @ 10 kΩ  
  • ...  
    Capacitance measurement:  ...  
  • 20 nF ± (4% + 3)  @ 0.01 nF,
  • 2 µF ± (4% + 3)  @ 0.001 µF,
  • 200 µF ± (5% + 5)  @ 0.1 µF  
  • ...  
    Inductance measurement:  ...    ...  
    Frequency measurement:  ...  
  • 2 kHz ± (1.5% + 5)  @ 1 Hz,
  • 200 MHz ± (1.5% + 5)  @ 100 Hz  
  • ...  
    Temperature measurement:  ...  
  • -40 °C ... -20 °C ± (8% + 5)  @ 1 °C,
  • -20 °C ... 0 °C ± (1.2% + 4)  @ 1 °C,
  • 0  ... 100 °C ± (1.2% + 3)  @ 1 °C,
  • 100  ... 1000 °C ± (2.5% + 2)  @ 1 °C  
  • ...  
    Automatic change of measuring ranges:  ...    ...  
    hFE:  ...    ...  
    Diode test:  ...    ...  
    Sound signal of the continuity test:  ...    ...  
    Checking TTL logic states:  ...    ...  
    RS-232:  ...    ...  
    USB:  ...    ...  
    Main features:  
  • Product is made from chrome-vanadium steel,
  • Full polish chrome plating for strength and durability, and easy cleaning,
  • Corrosion resistance,
  • Fork and polygonal head inclined by 15° for better accessibility to the nut or bolt,
  • Anti-slip profile - wrench profile shape optimizes contact with the bolt, preventing the wrench from slipping,
  • 12 point versatile ring spanner end for easy installation  
  • Large, readable LCD display with backlight
  • Hold - stopping the meter reading
  • Aesthetic and solid construction  
  • ...  
    Power supply:  ...  
  • 6 x 1.5V, type R14/LR14 battery (not included),
  • 9 V DC / 200 mA (power adapter included)  
  • 12 V DC  
    Weight:  0.162 kg  1.61 kg  0.16 kg  
    Dimensions:  231  x 40  x 11 mm  306  x 243  x 107 mm  120  x 92  x 14 mm  
    Manufacturer / Brand:  STANLEY  UNI-T  SATEL  
    Guarantee:  2 years  2 years  2 years