CABLES TESTER FS-8114 FORSCHER


MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-595 UNI-T

128.90 EUR
128.90 EUR

573.99 EUR
573.99 EUR

Tested cables:  STP / UTP cat. 5, 5e, 6 - RJ45 (8P8C), RJ11 (6P4C), Coaxial cable  ...  
Resistance measurement:  ...  
  • Test voltage 250 V : 0.05 MΩ ... 250 MΩ
  • Test voltage 500 V : 0.05 MΩ ... 500 MΩ
  • Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ  
  • Measuring accuracy:  ...  0.05 MΩ ... 1000 MΩ ± (5% + 5)   
    Open circuit voltage:  ...  Test voltage ± 10 %  
    Test current:  ...  0.9 mA ... 1.1 mA  
    Short-circuit current:  ...  < 1.8 mA  
    AC voltage measurement:  ...  0 V ... 440 V ± (2% + 3)  @ 1 V  
    DC voltage measurement:  ...  0 V ... ± 440 V ± (2% + 3)  @ 1 V  
    Measurement of small resistances:  ...  0.01 Ω ... 200 Ω ± (2% + 5)   
    Frequency measurement:  ...  20 Hz ... 100 Hz - for reference only  
    Test of RCDs:  ...  
  • Working voltage: 220V ± 10 %
  • Test current: 10mA / 30mA / 100mA / 300mA / 500mA
  • Switch-off time ranges :
    • 0 ... 2000 ms ± (5% + 5)  @ 1/2 x nominal value of the residual current
    • 0 ... 500 ms ± (5% + 5)  @ 1 x  nominal value of the residual current, Selective RCD
    • 0 ... 500 ms ± (5% + 5)  @ 2 x nominal value of the residual current, Selective RCD
    • 0 ... 300 ms ± (5% + 5)  @ 1 x nominal value of the residual current
    • 0 ... 300 ms ± (5% + 5)  @ 2 x nominal value of the residual current
    • 0 ... 40 ms ± (5% + 5)  @ 5 x nominal value of the residual current
     
  • RCD tripping current measurement:  ...  
    Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 %  
    RCD automatic test:  ...    
    Phase sequence test:  ...  100 V ... 440 V / 45 Hz ... 65 Hz  
    Continuity measurement of protective and equalizing conductors:  ...  0 Ω ... 199 Ω ± (2% + 5) 
    Measuring current > 20 mA @ 0 ... 2 Ω  
    Line impedance measurement (L-N):  ...  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    Short circuit loop impedance measurement (L-PE):  ...  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    Automatic change of measuring ranges:  ...    
    RS-232:  ...    
    USB:  ...    
    Main features:  
  • OSD menu : Polish, English
  • Large, readable LCD display with backlight
  • Cable length measurement
  • Length of the cables : 1  ... 2000 m
  • Measurement method : capacitive
  • Measurement frequency : 130 kHz
  • "Find port" function – quick search of the port in a network device
  • Searching and testing cables in PoE mode
  • Measurement of voltages on PoE conductors
  • Pair integrity test
  • Built-in VFL laser fiber tester - max. 10 km, Connectors : 2.5 mm SC/FC/ST type
  • Save measurement results in the device memory
  • Overvoltage protection : 60 V AC / 48 V DC - Transmitter
  • Automatic power-off
  • Low battery level alarm  
  • Warning of using high voltage during the measurement,
  • Phase switch 0° / 180° during RCD test,
  • Automatic identification of AC/DC voltage,
  • Reset function for measuring low resistances,
  • Large, readable LCD display with backlight,
  • Buzzer,
  • Automatic power-off,
  • Low battery indicator,
  • Aesthetic and solid construction  
  • Operation temp:  ...  0 °C ... 40 °C  
    Permissible relative humidity:  ...  ≤ 85 % (non-condensing)  
    Power supply:  2 x 9V, type 6F22 battery ( Transmitter / Receiver - included )  8 x 1.5V, type AA/LR6/FR6 battery - included  
    Weight:  0.21 kg - Transmitter
    0.14 kg - Receiver  
    1.1 kg  
    Dimensions:  152  x 78  x 35 mm - Transmitter
    210  x 46  x 30 mm - Receiver  
    210  x 175  x 90 mm  
    Manufacturer / Brand:  FORSCHER  UNI-T  
    Guarantee:  2 years  2 years