- Show All - Show differences - Back | ACCESS CONTROLLER ASI1212F DAHUA | EXTENDER VGA-EX-30 | MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-593 UNI-T |
| | | |
| 226.35 EUR 226.35 EUR
| 41.82 EUR 41.82 EUR
| 349.84 EUR 349.84 EUR
|
Device type: | ... | Passive | ... |
Cards support: | 13.56 MHz S50 | ... | ... |
Reading distance of prox-keys: | 1 ... 3 cm | ... | ... |
Video transmission range: | ... | max. 180 m | ... |
Keyboard built-in: | | ... | ... |
Symmetrical socket impedance: | ... | 100 Ω | ... |
Autonomous operation: | | ... | ... |
Battery backup support: | | ... | ... |
Input lines: | 3 | ... | ... |
Output lines: | 3 | ... | ... |
Identification time: | < 1.5 s | ... | ... |
Connectors type: | ... | 1 x VGA - Socket 1 x RJ-45 - Socket | ... |
Communication: | RS-485 Wiegand LAN | ... | ... |
RS-485 interface: | | ... | ... |
RS-232 interface: | | ... | ... |
Resistance measurement: | ... | ... | Test voltage 250 V : 0.05 MΩ ... 250 MΩ Test voltage 500 V : 0.05 MΩ ... 500 MΩ Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ |
Wiegand interface: | | ... | ... |
Network interface: | 10/100 Base-T | ... | ... |
Measuring accuracy: | ... | ... | 0.05 MΩ ... 1000 MΩ ± (5% + 5) |
Default IP address: | 192.168.1.108 | ... | ... |
Open circuit voltage: | ... | ... | Test voltage ± 10 % |
Default admin user / password: | admin / - The administrator password should be set at the first start | ... | ... |
Test current: | ... | ... | 0.9 mA ... 1.1 mA |
Memory card slot: | | ... | ... |
Short-circuit current: | ... | ... | < 1.8 mA |
Internal memory: | Support storage of 150 000 records | ... | ... |
AC voltage measurement: | ... | ... | 0 V ... 440 V ± (2% + 3) @ 1 V |
DC voltage measurement: | ... | ... | 0 V ... ± 440 V ± (2% + 3) @ 1 V |
Measurement of small resistances: | ... | ... | 0.01 Ω ... 200 Ω ± (2% + 5) |
Frequency measurement: | ... | ... | 20 Hz ... 100 Hz - for reference only |
Resolution: | ... | 1920 x 1200 px WUXGA @ 45 m (manufacturer data) @ 30 m (our tests result), 1600 x 1200 px UXGA @ 45 m (manufacturer data) @ 30 m (our tests result), 1280 x 1024 px SXGA @ 60 m (manufacturer data) @ 40 m (our tests result), 1280 x 768 px WXGA @ 60 m (manufacturer data) @ 40 m (our tests result), 1024 x 768 px XGA @ 75 m (manufacturer data) @ 50 (our tests result), 800 x 600 px SVGA @ 120 m (manufacturer data) @ 80 m (our tests result), 640 x 480 px VGA @ 180 m (manufacturer data) @ 120 m (our tests result) | ... |
Bandwidth: | ... | ≤ 60 MHz DC | ... |
Insertion loss: | ... | < 3 dB | ... |
Grounding: | ... | via grounding bolt | ... |
"Index of Protection": | | ... | ... |
Test of RCDs: | ... | ... | Working voltage: 220V ± 10 % Test current: 10mA / 30mA / 100mA / 300mA / 500mA Switch-off time ranges :
- 0 ... 2000 ms ± (5% + 5) @ 1/2 x nominal value of the residual current
- 0 ... 500 ms ± (5% + 5) @ 1 x nominal value of the residual current, Selective RCD
- 0 ... 300 ms ± (5% + 5) @ 1 x nominal value of the residual current
- 0 ... 40 ms ± (5% + 5) @ 5 x nominal value of the residual current
|
Supported languages: | English | ... | ... |
RCD tripping current measurement: | ... | ... | Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 % |
RCD automatic test: | ... | ... | |
Phase sequence test: | ... | ... | 100 V ... 440 V / 45 Hz ... 65 Hz |
Continuity measurement of protective and equalizing conductors: | ... | ... | 0 Ω ... 199 Ω ± (2% + 5) Measuring current > 20 mA @ 0 ... 2 Ω |
Line impedance measurement (L-N): | ... | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA |
Short circuit loop impedance measurement (L-PE): | ... | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA |
Automatic change of measuring ranges: | ... | ... | |
RS-232: | ... | ... | |
USB: | | ... | |
Main features: | Built-in LCD display 240 x 320 px - 2.8 " capacitive touch screen Fingerprint reader built-in Memory of 3000 fingerprint patterns Possible connection of the external ASR series reader (read in/out door control) Identification modes : Proximity identifier 13.56 MHz S50, Fingerprint, PIN, Any combination of the above Remote access verification Tamper detection - removing from mounting surface Support for door contact and exit button Indication of forced entry and the lack of closing doors 30000 indexed users Possibility to configure access groups 128 General Purpose Schedules 128 time periods within single Schedule Holiday Schedules Anti-passback Integration with an alarm system via in/out line Remote programming from PC | ... | Warning of using high voltage during the measurement, Phase switch 0° / 180° during RCD test, Automatic identification of AC/DC voltage, Reset function for measuring low resistances, Large, readable LCD display with backlight, Buzzer, Automatic power-off, Low battery indicator, Aesthetic and solid construction |
Operation temp: | -10 °C ... 45 °C | 0 °C ... 55 °C | 0 °C ... 40 °C |
Permissible relative humidity: | 5 ... 90 % (non-condensing) | ≤ 95 % | ≤ 85 % (non-condensing) |
Power supply: | 12 V DC / 1 A | | 8 x 1.5V, type AA/LR6/FR6 battery - included |
Weight: | 0.22 kg | 0.06 kg | 1.1 kg |
Dimensions: | 115 x 115 x 32 mm | 64 x 61 x 25 mm | 210 x 175 x 90 mm |
Manufacturer / Brand: | DAHUA | ... | UNI-T |
Guarantee: | 3 years | 2 years | 2 years |