- Show All - Show differences - Back | AHD WIRELESS CAMERA ATE-W-CAM720-C1 - 720p 2.8 mm AUTONE | MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-595 UNI-T | TV OR MONITOR MOUNT BRATECK-LPA68-221 | SWITCHING ADAPTER NDR-75-24 MEAN WELL |
| | | | |
| 36.50 EUR 36.50 EUR
| 574.87 EUR 574.87 EUR
| 7.18 EUR 7.18 EUR
| 30.17 EUR 30.17 EUR
|
Standard: | AHD | ... | ... | ... |
Adapter type: | ... | ... | ... | Switching |
Sensor: | 1/3 " CMOS | ... | ... | ... |
Matrix size: | 1.0 Mpx | ... | ... | ... |
Mounting standard: | ... | ... | VESA : 100, 200, 200x100 | ... |
Resolution: | 1280 x 720 - 720p | ... | ... | ... |
Power voltage: | ... | ... | ... | 85 ... 264 V AC 120 ... 370 V DC |
Lens: | 2.8 mm | ... | ... | ... |
Screen size range: | ... | ... | 23 " ... 43 " | ... |
Output voltage: | ... | ... | ... | 24 V DC |
View angle: | 70 ° | ... | ... | ... |
Bearing capacity: | ... | ... | 30 kg | ... |
Output voltage adjustment: | ... | ... | ... | 24 ... 28 V DC |
Maximal load: | ... | ... | ... | 3.2 A |
Distance from mounting surface: | ... | ... | 56 ... 204 mm | ... |
Output power: | ... | ... | ... | 76.8 W |
Range of IR illumination: | 10 m | ... | ... | ... |
Number of outputs: | ... | ... | ... | 1 pcs |
S/N ratio: | ≥ 50 dB | ... | ... | ... |
Tilt adjustment: | ... | ... | -8 ° ... 5 ° | ... |
Efficiency: | ... | ... | ... | 88 % |
RS-485 interface: | | ... | ... | ... |
Housing type: | ... | ... | ... | DIN |
Memory card slot: | | ... | ... | ... |
Horizontal rotation: | ... | ... | -90 ° ... 90 ° | ... |
Rotation in the plane of the screen: | ... | ... | | ... |
Image compression method: | H.264 | ... | ... | ... |
ONVIF: | | ... | ... | ... |
Resistance measurement: | ... | Test voltage 250 V : 0.05 MΩ ... 250 MΩ Test voltage 500 V : 0.05 MΩ ... 500 MΩ Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ | ... | ... |
Alarm inputs / outputs: | | ... | ... | ... |
Audio: | | ... | ... | ... |
Measuring accuracy: | ... | 0.05 MΩ ... 1000 MΩ ± (5% + 5) | ... | ... |
Protections: | ... | ... | ... | Short-circuit Overload Overvoltage Overheat |
Main stream frame rate: | 20 fps @ 720p | ... | ... | ... |
Open circuit voltage: | ... | Test voltage ± 10 % | ... | ... |
Network interface: | Wi-Fi : IEEE 802.11 b/g | ... | ... | ... |
Test current: | ... | 0.9 mA ... 1.1 mA | ... | ... |
Operation temp. / Relative humidity: | ... | ... | ... | -20 °C ... 70 °C / 20 ... 95 % |
Short-circuit current: | ... | < 1.8 mA | ... | ... |
Main features: | 2D-DNR - Digital Noise Reduction Auto White Balance AGC - Automatic Gain Control BLC - Back Light Compensation | ... | ... | ... |
AC voltage measurement: | ... | 0 V ... 440 V ± (2% + 3) @ 1 V | ... | ... |
Power consumption: | ≤ 3.6 W | ... | ... | ... |
DC voltage measurement: | ... | 0 V ... ± 440 V ± (2% + 3) @ 1 V | ... | ... |
Mobile phones support: | | ... | ... | ... |
Default IP address: | | ... | ... | ... |
Default user password: | | ... | ... | ... |
Measurement of small resistances: | ... | 0.01 Ω ... 200 Ω ± (2% + 5) | ... | ... |
Web browser access ports: | | ... | ... | ... |
PC client access ports: | | ... | ... | ... |
Housing: | Metal | ... | ... | ... |
Color: | Silver | ... | Black | ... |
Frequency measurement: | ... | 20 Hz ... 100 Hz - for reference only | ... | ... |
"Index of Protection": | IP67 | ... | ... | ... |
Operation temp: | -30 °C ... 70 °C | ... | ... | ... |
Supported languages: | English | ... | ... | ... |
Test of RCDs: | ... | Working voltage: 220V ± 10 % Test current: 10mA / 30mA / 100mA / 300mA / 500mA Switch-off time ranges :
- 0 ... 2000 ms ± (5% + 5) @ 1/2 x nominal value of the residual current
- 0 ... 500 ms ± (5% + 5) @ 1 x nominal value of the residual current, Selective RCD
- 0 ... 500 ms ± (5% + 5) @ 2 x nominal value of the residual current, Selective RCD
- 0 ... 300 ms ± (5% + 5) @ 1 x nominal value of the residual current
- 0 ... 300 ms ± (5% + 5) @ 2 x nominal value of the residual current
- 0 ... 40 ms ± (5% + 5) @ 5 x nominal value of the residual current
| ... | ... |
RCD tripping current measurement: | ... | Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 % | ... | ... |
RCD automatic test: | ... | | ... | ... |
Phase sequence test: | ... | 100 V ... 440 V / 45 Hz ... 65 Hz | ... | ... |
Continuity measurement of protective and equalizing conductors: | ... | 0 Ω ... 199 Ω ± (2% + 5) Measuring current > 20 mA @ 0 ... 2 Ω | ... | ... |
Line impedance measurement (L-N): | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA | ... | ... |
Short circuit loop impedance measurement (L-PE): | ... | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA | ... | ... |
Automatic change of measuring ranges: | ... | | ... | ... |
RS-232: | ... | | ... | ... |
USB: | ... | | ... | ... |
Main features: | ... | Warning of using high voltage during the measurement, Phase switch 0° / 180° during RCD test, Automatic identification of AC/DC voltage, Reset function for measuring low resistances, Large, readable LCD display with backlight, Buzzer, Automatic power-off, Low battery indicator, Aesthetic and solid construction | ... | ... |
Operation temp: | ... | 0 °C ... 40 °C | ... | ... |
Permissible relative humidity: | ... | ≤ 85 % (non-condensing) | ... | ... |
Power supply: | 12 V DC / 300 mA, 24 V DC / 150 mA | 8 x 1.5V, type AA/LR6/FR6 battery - included | ... | ... |
Weight: | 0.53 kg | 1.1 kg | 1.03 kg | 0.43 kg |
Dimensions: | 82 x 100 x 78 mm | 210 x 175 x 90 mm | 230 x 230 x (56 ... 205) mm | 126 x 115 x 32 mm |
Manufacturer / Brand: | AUTONE | UNI-T | BRATECK | MEAN WELL |
Guarantee: | 2 years | 2 years | 2 years | 3 years |