![](img/compere_shop_all.png) - Show All ![](img/compere_shop_identical.png) - Show differences - Back | ![](img/eclose_grey.png) CARBON MONOXIDE (CO) DETECTOR CD-77A4 EURA | ![](img/eclose_grey.png) UPS AT-UPS1500S-RT-RACK 1500 VA EAST |
| ![CD-77A4 Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/cd-77a4_m.jpg) | ![AT-UPS1500S-RT-RACK Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/at-ups1500s-rt-rack_m.jpg) |
| 13.15 GBP 13.15 GBP
| 261.54 GBP 261.54 GBP
|
Detection: | Carbon Monoxide (CO) | ... |
Power adapter type: | ... | Line-interactive |
Nominal power: | ... | 1200 W |
Alarm signaling: | Alarm siren Blinking LED | ... |
Apparent Power: | ... | 1500 VA |
Input voltage: | ... | 230 V AC ± 25 % |
Gas concentration to trigger alarm: | 30 ppm for >120 minutes 50 ppm for 60 ... 90 minutes 100 ppm for 10 ... 40 minutes 300 ppm for max. 3 mins | ... |
Input frequency: | ... | 50 / 60 Hz (auto detection) |
Output voltage: | ... | 230 V AC ± 10 % (Pure Sine Wave) |
Battery power supply: | 3 x battery LR6 (AA) (included) | ... |
Output frequency: | ... | 50 / 60 Hz ± 1 % |
Voltage adjustment: | ... | |
Frequency adjustment: | ... | |
Transfer time: | ... | ≤ 10 ms |
Charging time (recover to 90% capacity): | ... | 8 hours |
Battery: | ... | 2 x 12V/9Ah |
Operation temp: | 0 °C ... 40 °C | ... |
Estimated battery operation time: | ... | 41 minutes @ 100 W, 22 minutes @ 200 W, 15 minutes @ 300 W, 9 minutes @ 400 W, 6.5 minutes @ 500 W, 4 minutes @ 600 W, 2 minutes @ 700 W, 2 minutes @ 800 W, 1.5 minutes @ 900 W, 42 s @ 1000 W |
Number of outputs: | ... | 6 pcs - 3 x CEE 7/3 (Schuko), 3 x IEC C13 |
Management software: | ... | UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux) |
Protections: | ... | Fuse Short-circuit Overload Overvoltage - RJ45 Ethernet filter Output voltage filtering DC filter to eliminate interferences - EMI/RFI |
Operation state indication: | ... | LCD display: operation mode, battery charging level, in/out voltage level, overload indicator, LED diodes, Sound signaling |
Main features: | Low battery level alarm Current consumption < 90 μA (Standby mode) < 75 mA (alarm) Alarm siren 85 dB/m Detector range : 20 ... 25 m² LCD display Thermometer built-in Test mode The memory of the last highest concentration of CO, which triggered the alarm Failure signaling EN 50291-1:2010 compliance Detector lifetime : 5 years "Index of Protection" : IP20 | Auto restart while AC is recovering Excellent microprocessor control guarantees high reliability COLD START function for manual switch to the battery power supply Automatic Voltage Regulator (AVR) Battery charge and maintenance control 2 x RJ45 - Input / Output Port USB 2.0 - Access from PC Remote management - UPSmart application (included) Optical - sound signaling Built-in EMI, RFI filter Network card slot Can be mounted in a Rack 19" cabinet The device works with power supply adapters having Active Power Factor Correction (APFC) |
Application: | ... | Surveillance Systems data storage centers network, servers, workstations Industrial Equipment |
Housing type: | ... | Rack/Tower 2-in-1 Design |
Operation temp. / Relative humidity: | ... | 5 °C ... 40 °C / ≤ 93 % (non-condensing) |
Weight: | 0.22 kg | 17.1 kg |
Dimensions: | 120 x 90 x 40 mm | 440 x 132 x 410 mm ; RACK 19", 3U |
Manufacturer / Brand: | EURA | EAST |
Guarantee: | 2 years | 2 years |