- Show All - Show differences - Back | MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-595 UNI-T | SMART VALVE FOR THE IRRIGATION SYSTEM ATLO-VR1-BLE-TUYA Bluetooth BLE, Tuya Smart | SMART SWITCH ATLO-B1-TUYA Wi-Fi, Tuya Smart |
| | | |
| 581.52 EUR 581.52 EUR
| 24.26 EUR 24.26 EUR
| 5.25 EUR 5.25 EUR
|
Application: | ... | irrigation control | switching devices on/off |
Type (size): | ... | 3/4 " | ... |
Maximal total load: | ... | ... | 2400 W |
Total maximal current: | ... | ... | 10 A |
Number of inputs: | ... | ... | 1 |
Working pressure: | ... | 0.02 ... 0.8 MPa / 2.9 ... 116 psi | ... |
Number of outputs: | ... | ... | 1 |
Connector type: | ... | ... | screw terminals |
Opening/closing time: | ... | 5 ... 10 s | ... |
Radio communication range (at open area): | ... | 15 m | ... |
Wireless: | ... | Bluetooth | Wi-Fi, 2.4 GHz - IEEE 802.11 b/g/n |
Mobile phones support: | ... | The Tuya Smart free application on Android The Tuya Smart free application on iOS | The Tuya Smart free application on Android The Tuya Smart free application on iOS |
Resistance measurement: | Test voltage 250 V : 0.05 MΩ ... 250 MΩ Test voltage 500 V : 0.05 MΩ ... 500 MΩ Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ | ... | ... |
Measuring accuracy: | 0.05 MΩ ... 1000 MΩ ± (5% + 5) | ... | ... |
Open circuit voltage: | Test voltage ± 10 % | ... | ... |
Test current: | 0.9 mA ... 1.1 mA | ... | ... |
Short-circuit current: | < 1.8 mA | ... | ... |
AC voltage measurement: | 0 V ... 440 V ± (2% + 3) @ 1 V | ... | ... |
DC voltage measurement: | 0 V ... ± 440 V ± (2% + 3) @ 1 V | ... | ... |
Measurement of small resistances: | 0.01 Ω ... 200 Ω ± (2% + 5) | ... | ... |
Housing: | ... | Plastic (ABS) + Nylon, UV-resistant, Waterproof | Plastic |
Frequency measurement: | 20 Hz ... 100 Hz - for reference only | ... | ... |
"Index of Protection": | ... | IP55 | ... |
Color: | ... | Black | White |
Test of RCDs: | Working voltage: 220V ± 10 % Test current: 10mA / 30mA / 100mA / 300mA / 500mA Switch-off time ranges :
- 0 ... 2000 ms ± (5% + 5) @ 1/2 x nominal value of the residual current
- 0 ... 500 ms ± (5% + 5) @ 1 x nominal value of the residual current, Selective RCD
- 0 ... 500 ms ± (5% + 5) @ 2 x nominal value of the residual current, Selective RCD
- 0 ... 300 ms ± (5% + 5) @ 1 x nominal value of the residual current
- 0 ... 300 ms ± (5% + 5) @ 2 x nominal value of the residual current
- 0 ... 40 ms ± (5% + 5) @ 5 x nominal value of the residual current
| ... | ... |
RCD tripping current measurement: | Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 % | ... | ... |
RCD automatic test: | | ... | ... |
Phase sequence test: | 100 V ... 440 V / 45 Hz ... 65 Hz | ... | ... |
Continuity measurement of protective and equalizing conductors: | 0 Ω ... 199 Ω ± (2% + 5) Measuring current > 20 mA @ 0 ... 2 Ω | ... | ... |
Line impedance measurement (L-N): | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA | ... | ... |
Short circuit loop impedance measurement (L-PE): | 0.05 Ω ... 1.99 Ω ± (5% + 5) 2 Ω ... 19.99 Ω ± (5% + 5) 20 Ω ... 2000 Ω ± (5% + 5) Measuring current : 20 A / 20 ms Measuring range of prospective short-circuit current : 0 ... 26 kA | ... | ... |
Automatic change of measuring ranges: | | ... | ... |
RS-232: | | ... | ... |
USB: | | ... | ... |
Main features: | Warning of using high voltage during the measurement, Phase switch 0° / 180° during RCD test, Automatic identification of AC/DC voltage, Reset function for measuring low resistances, Large, readable LCD display with backlight, Buzzer, Automatic power-off, Low battery indicator, Aesthetic and solid construction | schedule, timer, manual watering (app or button), delay after rain : 24, 48, 72 h - the device will not turn on the sprinklers if it is raining, remote access - Bluetooth/Wi-Fi gateway, voice control STATUS indicator Low current consumption Easy installation - the valve is mounted directly on the tap 3/4" / 1/2" Adapter (included) | schedule, timer, remote access, voice control, The ability to set the default status of the device after a power failure Pairing button Wi-Fi indicator |
Operation temp: | 0 °C ... 40 °C | 4.5 °C ... 45 °C | -20 °C ... 50 °C |
Permissible relative humidity: | ≤ 85 % (non-condensing) | ... | ≤ 80 % |
Power supply: | 8 x 1.5V, type AA/LR6/FR6 battery - included | 2 x 1.5V, type AA/LR6/FR6 battery (not included) | 100 ... 240 V |
Weight: | 1.1 kg | 0.3 kg | 0.04 kg |
Dimensions: | 210 x 175 x 90 mm | 138 x 110 x 47 mm | 88 x 40 x 25 mm |
Manufacturer / Brand: | UNI-T | ... | ... |
Guarantee: | 2 years | 2 years | 2 years |