MULTIFUNCTION METER FOR ELECTRICAL INSTALLATIONS UT-593 UNI-T


LIVE WIRE, METAL AND WOOD DETECTOR UT-387B UNI-T


ACCESS CONTROLLER ASC2102B-T DAHUA


LED LIGHTING CONTROLLER FUT036S 2.4 GHz, MONO 12 ... 24 V DC MiBOXER / Mi-Light

8978.71 CZK
8978.71 CZK

1332.43 CZK
1332.43 CZK

4461.54 CZK
4461.54 CZK

120.62 CZK
120.62 CZK

Number of served transitions:  ...  ...  2 (two-way)  ...  
Support:  ...  ...  DAHUA ASC2204C-H  ...  
Application:  ...  ...  ...  Works with LED lighting - single-color (MONO) 12-24V LED strips  
Number of supported readers:  ...  ...  4 pcs  ...  
Battery backup support:  ...  ...    ...  
Rated voltage:  ...  ...  ...  12  ... 24 V DC  
Output lines:  ...  ...  5 pcs - Relay  ...  
Alarm inputs / outputs:  ...  ...  5 / 1   ...  
Detector range:  ...  
  • Wood : 20 mm,
  • Metal : 80 mm,
  • AC live wires : 50 mm  
  • ...  ...  
    Maximal total load:  ...  ...  ...  
  • 144 W @ 12 V,
  • 288 W @ 24 V  
  • Total maximal current:  ...  ...  ...  12 A  
    Number of inputs:  ...  ...  ...  1   
    Communication:  ...  ...  
  • RS-485,
  • Wiegand 34/26,
  • Control panel CAN (Controler Area Network)  
  • ...  
    Number of outputs:  ...  ...  ...  2 (power)  
    Resistance measurement:  
  • Test voltage 250 V : 0.05 MΩ ... 250 MΩ
  • Test voltage 500 V : 0.05 MΩ ... 500 MΩ
  • Test voltage 1000 V : 0.05 MΩ ... 1000 MΩ  
  • ...  ...  ...  
    Connector type:  ...  ...  ...  
  • screw terminals,
  • 5.5/2.1 socket / screw terminals - power input  
  • Measuring accuracy:  0.05 MΩ ... 1000 MΩ ± (5% + 5)   ...  ...  ...  
    Wireless:  ...  ...  ...  2.4 GHz  
    Radio communication range (at open area):  ...  ...  ...  30 m  
    Open circuit voltage:  Test voltage ± 10 %  ...  ...  ...  
    Test current:  0.9 mA ... 1.1 mA  ...  ...  ...  
    Short-circuit current:  < 1.8 mA  ...  ...  ...  
    Mobile phones support:  ...  ...  ...  Access by a cloud (P2P) - Gateway required WL-BOX2
  • The Tuya Smart free application on Android
  • The Tuya Smart free application on iOS  
  • Housing:  ...  ...  ...  Plastic  
    AC voltage measurement:  0 V ... 440 V ± (2% + 3)  @ 1 V  ...  ...  ...  
    Color:  ...  ...  ...  White  
    DC voltage measurement:  0 V ... ± 440 V ± (2% + 3)  @ 1 V  ...  ...  ...  
    Measurement of small resistances:  0.01 Ω ... 200 Ω ± (2% + 5)   ...  ...  ...  
    Frequency measurement:  20 Hz ... 100 Hz - for reference only  ...  ...  ...  
    Test of RCDs:  
  • Working voltage: 220V ± 10 %
  • Test current: 10mA / 30mA / 100mA / 300mA / 500mA
  • Switch-off time ranges :
    • 0 ... 2000 ms ± (5% + 5)  @ 1/2 x nominal value of the residual current
    • 0 ... 500 ms ± (5% + 5)  @ 1 x  nominal value of the residual current, Selective RCD
    • 0 ... 300 ms ± (5% + 5)  @ 1 x nominal value of the residual current
    • 0 ... 40 ms ± (5% + 5)  @ 5 x nominal value of the residual current
     
  • ...  ...  ...  
    RCD tripping current measurement:  
    Increasing current test: 10 mA / 30 mA / 100 mA / 300 mA / 500 mA ± 10 %  
    ...  ...  ...  
    RCD automatic test:    ...  ...  ...  
    Phase sequence test:  100 V ... 440 V / 45 Hz ... 65 Hz  ...  ...  ...  
    Continuity measurement of protective and equalizing conductors:  0 Ω ... 199 Ω ± (2% + 5) 
    Measuring current > 20 mA @ 0 ... 2 Ω  
    ...  ...  ...  
    Line impedance measurement (L-N):  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    ...  ...  ...  
    Short circuit loop impedance measurement (L-PE):  
  • 0.05 Ω ... 1.99 Ω ± (5% + 5) 
  • 2 Ω ... 19.99 Ω ± (5% + 5) 
  • 20 Ω ... 2000 Ω ± (5% + 5) 
  • Measuring current : 20 A / 20 ms
    Measuring range of prospective short-circuit current : 0  ... 26 kA  
    ...  ...  ...  
    Automatic change of measuring ranges:    ...  ...  ...  
    RS-232:    ...  ...  ...  
    USB:    ...  ...  ...  
    Main features:  
  • Warning of using high voltage during the measurement,
  • Phase switch 0° / 180° during RCD test,
  • Automatic identification of AC/DC voltage,
  • Reset function for measuring low resistances,
  • Large, readable LCD display with backlight,
  • Buzzer,
  • Automatic power-off,
  • Low battery indicator,
  • Aesthetic and solid construction  
  • Automatic calibration after turned on,
  • Optical - sound signaling,
  • ZOOM function - More precise location of small metal elements with visualization of their location  
  • 20 000 indexed users
  • History of 30 000 events
  • Function to prevent of multiple use of the same code/card to gain access (anti-passback)
  • Door Left Open and Door Forced Open alarms
  • Watchdog built-in
  • Possibility to mount on a wall, or on the DIN TS-35 rail  
  • The repeater function allows you to transfer control to subsequent FUT035S / FUT036S / FUT038S / FUT039 modules even beyond the direct range of the remote control  
    Operation temp:  0 °C ... 40 °C  ...  -30 °C ... 60 °C  -10 °C ... 40 °C  
    Permissible relative humidity:  ≤ 85 % (non-condensing)  ...  max. 95 % (non-condensing)  ...  
    Power supply:  8 x 1.5V, type AA/LR6/FR6 battery - included  9V, type 6F22 battery - included  12 V DC / 1 A  ...  
    Weight:  1.1 kg  0.23 kg - Without batteries  0.384 kg  0.03 kg  
    Dimensions:  210  x 175  x 90 mm  220  x 83  x 36 mm  209  x 117  x 51 mm  75  x 36  x 17 mm  
    Manufacturer / Brand:  UNI-T  UNI-T  DAHUA  MiBOXER / Mi-Light  
    Guarantee:  2 years  2 years  3 years  2 years