TopProducts Comparison
- Show All
- Show differences
- Back

UNIVERSAL METER UT-181A UNI-T


ACCESS CONTROLLER WITH TEMPERATURE MEASUREMENT APTI-AI70FRTD-V2 4.5 mm - 1080p


SMART CONTROLLER FOR ROLLER SHUTTERS SHUTTERBOX-DC-V2/BLEBOX Wi-Fi, 12 ... 24 V DC

365.07 EUR
365.07 EUR

58.30 EUR
58.30 EUR

37.33 EUR
37.33 EUR

Application:  ...  ...  roller shutters, roof windows, awnings, drop-down screens, curtains  
Rated voltage:  ...  ...  12  ... 24 V DC  
Scanning system:  ...  Progressive  ...  
Maximal total load:  ...  ...    
Optical zoom:  ...    ...  
Total maximal current:  ...  ...  
  • 4.5 A (max)
  • 3 A @ 180 s @ 200 g - Thermal protection  
  • Number of inputs:  ...  ...  2   
    Number of outputs:  ...  ...  2   
    Sensor:  ...  1/2.8 " SONY Starvis™ Back-illuminated CMOS
    1/5 " GC2145  
    ...  
    Matrix size:  ...  
    2.1 Mpx
    2 Mpx  
    ...  
    Connector type:  ...  ...  
    screw terminals  
    Pixel pitch:  ...  
    1.75 µm  
    ...  
    Lens:  ...  
    4.5 mm 2.4 mm  
    ...  
    View angle:  ...  68 °
    70 °  
    ...  
    Wireless:  ...  ...  
    Wi-Fi, 2.4 GHz - IEEE 802.11g  
    Resolution:  ...  1920 x 1080  - 1080p
    800 x 600  - 0.48 Mpx  
    ...  
    Mobile phones support:  ...  ...  
  • The wBox free application on Android
  • The wBox free application on iOS  
  • Standard:  ...  TCP/IP  ...  
    Range of IR illumination:  ...  5 m  ...  
    White light LED illuminator range:  ...  5 m  ...  
    DC voltage measurement:  60 mV ± (0.025% + 20)  @ 0.001 mV ,
    600 mV ± (0.025% + 5)  @ 0.01 mV ,
    6 V ± (0.025% + 5)  @ 0.0001 V ,
    60 V ± (0.025% + 5)  @ 0.001 V ,
    600 V ± (0.03% + 5)  @ 0.01 V ,
    1000 V ± (0.03% + 5)  @ 0.1 V  
    ...  ...  
    Temperature measurement range:  ...  35 °C ... 42 °C  ...  
    Accuracy of temperature measurement:  ...  ± 0.3 °C  ...  
    Face recognition distance:  ...  0.5 m ... 1.5 m (max 30 000 faces in the database)  ...  
    Temperature measurement distance:  ...  0.5 m ... 1.3 m
    optimal distance : 0.75 m  
    ...  
    Internal memory:  ...  Support storage of 25 000 records  ...  
    Video output:  ...    ...  
    RS-485 interface:  ...    ...  
    Wiegand interface:  ...    ...  
    Operation temp:  ...  ...  -20 °C ... 50 °C  
    Memory card slot:  ...    ...  
    Alarm inputs / outputs:  ...  0 / 2  ( bolt control, signaling of exceeding the temperature )  ...  
    Audio:  ...  Speaker built-in  ...  
    Network interface:  ...  10/100 Base-T (RJ-45)  ...  
    Network protocols:  ...  IPv4, HTTP, HTTPS, TCP/IP  ...  
    WEB Server:  ...  Built-in  ...  
    Max. number of on-line users:  ...  20   ...  
    ONVIF:  ...    ...  
    RS-485:  ...    ...  
    Default IP address:  ...  DHCP / 192.168.1.88   ...  
    Default admin user / password:  ...  admin / 12345  ...  
    Web browser access ports:  ...  7080   ...  
    PC client access ports:  ...  7080   ...  
    Main features:  ...  
  • Built-in LCD display showing the image from the video camera and the result of temperature measurement - 1024 x 600 px
  • Wiegand 26
  • Day/Night mode (color/b&w/auto)
  • RESET button
  • Relay output operating modes: access control or notification of an exception  
  • ...  
    Power consumption:  ...  ≤ 12 W  ...  
    Housing:  ...  Compact - Metal  Plastic  
    Color:  ...  Silver  Black  
    "Index of Protection":  ...  IP66  IP20  
    Operation temp:  ...  15 °C ... 25 °C - temperature measurement only in closed rooms (stabilized temperature)  ...  
    Montage hole diameter:  ...  33 mm  ...  
    Length of the cable:  ...  64 cm  ...  
    Supported languages:  ...  Polish, English, French, Spanish, German, Portuguese, Russian, Turkish, Italian  ...  
    AC voltage measurement:  
  • 60 mV @ 0.001 mV :
  • ± (0.6% + 60)  @ 45 Hz ... 1 kHz ,
    ± (1.2% + 60)  @ >1 kHz ... 10 kHz ,
    ± (3.0% + 60)  @ >10 kHz ... 20 kHz ,
    ± (4.0% + 60)  @ >20 kHz ... 100 kHz ,

  • 600 mV @ 0.01 mV :
  • ± (0.3% + 30)  @ 45 Hz ... 1 kHz
    ± (1.2% + 40)  @ >1 kHz ... 10 kHz
    ± (3.0% + 40)  @ >10 kHz ... 20 kHz
    ± (4.0% + 40)  @ >20 kHz ... 100 kHz ,

  • 6 V @ 0.0001 V :
  • ± (0.3% + 30)  @ 45 Hz ... 1 kHz
    ± (1.2% + 40)  @ >1 kHz ... 10 kHz
    ± (3.0% + 40)  @ >10 kHz ... 20 kHz
    ± (4.0% + 40)  @ >20 kHz ... 100 kHz ,

  • 60 V @ 0.001 V :
  • ± (0.3% + 30)  @ 45 Hz ... 1 kHz
    ± (1.2% + 40)  @ >1 kHz ... 10 kHz
    ± (3.0% + 40)  @ >10 kHz ... 20 kHz
    ± (4.0% + 40)  @ >20 kHz ... 100 kHz

  • 600 V @ 0.01 V :
  • ± (0.3% + 30)  @ 45 Hz ... 1 kHz
    ± (1.2% + 40)  @ >1 kHz ... 10 kHz ,
    ± (3.0% + 40)  @ >10 kHz ... 20 kHz ,

  • 1000 V @ 0.1 V :
  • ± (0.6% + 30)  @ 45 Hz ... 1 kHz
    ± (3.0% + 40)  @ >1 kHz ... 5 kHz ,
    ± (6.0% + 40)  @ >5 kHz ... 10 kHz  
    ...  ...  
    DC current measurement:  600 µA ± (0.08% + 20)  @ 0.01 µA ,
    6000 µA ± (0.08% + 10)  @ 0.1 µA ,
    60 mA ± (0.08% + 20)  @ 0.001 mA ,
    600 mA ± (0.15% + 10)  @ 0.01 mA ,
    10 A ± (0.5% + 10)  @ 0.001 A  
    ...  ...  
    AC current measurement:  
  • 600 µA @ 0.01 µA :
  • ± (0.6% + 40)  @ 45 Hz ... 1 kHz
    ± (1.2% + 40)  @ >1 kHz ... 10 kHz

  • 6000 µA @ 0.1 µA :
  • ± (0.6% + 20)  @ 45 Hz ... 1 kHz
    ± (1.2% + 40)  @ >1 kHz ... 10 kHz

  • 60 mA @ 0.001 mA :
  • ± (0.6% + 40)  @ 45 Hz ... 1 kHz
    ± (1.2% + 40)  @ >1 kHz ... 10 kHz

  • 600 mA @ 0.01 mA :
  • ± (0.6% + 20)  @ 45 Hz ... 1 kHz
    ± (1.2% + 40)  @ >1 kHz ... 10 kHz

  • 10 A @ 0.001 A :
  • ± (1.0% + 20)  @ 45 Hz ... 1 kHz
    ± (3.0% + 40)  @ >1 kHz ... 10 kHz  
    ...  ...  
    Resistance measurement:  600 Ω ± (0.05% + 10)  @ 0.01 Ω ,
    6 kΩ ± (0.05% + 2)  @ 0.0001 kΩ ,
    60 kΩ ± (0.05% + 2)  @ 0.001 kΩ ,
    600 kΩ ± (0.05% + 2)  @ 0.01 kΩ ,
    6 MΩ ± (0.3% + 10)  @ 0.0001 MΩ ,
    60 MΩ ± (2.0% + 10)  @ 0.001 MΩ  
    ...  ...  
    Capacitance measurement:  6 nF ± (3.0% + 10)  @ 0.001 nF ,
    60 nF ± (2.5% + 5)  @ 0.01 nF ,
    600 nF ± (2.0% + 5)  @ 0.1 nF ,
    6 µF ± (2.0% + 5)  @ 0.001 µF ,
    60 µF ± (2.0% + 5)  @ 0.01 µF
    600 µF ± (2.0% + 5)  @ 0.1 µF ,
    6 mF ± (5.0% + 5)  @ 0.001 mF ,
    60 mF @ 0.01 mF - visual measurement  
    ...  ...  
    Inductance measurement:    ...  ...  
    Frequency measurement:  60 Hz ± (0.02% + 8)  @ 0.001 Hz ,
    600 Hz ± (0.01% + 5)  @ 0.01 Hz ,
    6 kHz ± (0.01% + 5)  @ 0.0001 kHz ,
    60 kHz ± (0.01% + 5)  @ 0.001 kHz ,
    600 kHz ± (0.01% + 5)  @ 0.01 kHz ,
    6 MHz ± (0.01% + 5)  @ 0.0001 MHz ,
    60 MHz ± (0.01% + 5)  @ 0.001 MHz  
    ...  ...  
    Square-wave signal duty ratio measurement:  10 % ... 90 % ± (1.2% + 30)  @ 0.01 %  ...  ...  
    Pulse width measurement:  250 ms ± (1.2% + 30)  @ 0.001 ms ... 0.01 ms  ...  ...  
    Temperature measurement:  
  • °C
  • -40  ... 40 °C ± (2.0% + 30)  @ 0.1 °C
    >40  ... 400 °C ± (1.0% + 30)  @ 0.1 °C
    >400  ... 1000 °C ± 2.5%  @ 0.1 °C,
  • °F
  • -40  ... 104 °F ± (2.5% + 50)  @ 0.1 °F
    >104  ... 752 °F ± (1.5% + 50)  @ 0.1 °F
    >752  ... 1832 °F ± 2.5%  @ 0.1 °F  
     ...  
    Automatic change of measuring ranges:    ...  ...  
    hFE:    ...  ...  
    Diode test:    ...  ...  
    Sound signal of the continuity test:    ...  ...  
    Checking TTL logic states:    ...  ...  
    RS-232:    ...  ...  
    USB:    ...  ...  
    Main features:  
  • True RMS - accurate measurement of the RMS current and voltage for any waveform,
  • Freezing the last reading,
  • Freezing the highest or lowest measurement,
  • Writing the value peak,
  • REL - relative measurement mode,
  • Analog bargraph,
  • Possibility to save readings, access saved results and send them to a computer using the USB interface,
  • Large, easy to read LCD graphic display with backlight,
  • The ability to draw a trend graph of changes in the measured value over time based on the data stored in the device from continuous measurement,
  • Save to 20000 measurement results in the device memory,
  • Voltage level measurement (dBV/dBm),
  • Low battery level alarm,
  • Aesthetic and solid construction,
  • The set includes a practical case  
  • ...  
  • schedule,
  • timer,
  • sunrise and sunset mode,
  • remote access,
  • voice control,
  • μWiFi technology support
  • Ability to work with mechanical and electronic limit switches
  • Ability to work with motors without limit switches (overload)
  • "Soft Start" function
  • Automatic calibration  
  • Power supply:  Built-in battery 7.4V / 2200mAh, the set includes a 10V / 500mA power supply and a power adapter for charging the battery  12 V DC  ...  
    Weight:  0.62 kg  0.94 kg  0.02 kg  
    Dimensions:  226  x 104  x 63 mm  305  x 112  x 59 mm  38  x 33  x 20 mm  
    Manufacturer / Brand:  UNI-T  APTI  BleBox  
    Guarantee:  2 years  3 years  2 years