![](img/compere_shop_all.png) - Show All ![](img/compere_shop_identical.png) - Show differences - Back | ![](img/eclose_grey.png) CLAMP METER UT-213C UNI-T | ![](img/eclose_grey.png) SMART GATE AND DOOR CONTROLLER SBW-02/ANT Wi-Fi, 12 ... 24 V AC/DC ZAMEL |
| ![UT-213C Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/ut-213c_m.jpg) | ![SBW-02/ANT Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/sbw-02-ant_m.jpg) |
| 70.02 EUR 70.02 EUR
| 75.14 EUR 75.14 EUR
|
Support: | ... | SUPLA |
Application: | ... | swing gates, sliding gates, garage gates, doors |
Rated voltage: | ... | 12 ... 24 V AC/DC |
Total maximal current: | ... | 3 A @ 24 V AC |
Number of inputs: | ... | 2 |
Number of outputs: | ... | 2 |
Connector type: | ... | screw terminals |
Wireless: | ... | Wi-Fi, 2.4 GHz - IEEE 802.11 b/g/n |
Mobile phones support: | ... | The SUPLA free application on Android The SUPLA free application on iOS |
DC voltage measurement: | 400 mV ± (1% + 8) @ 0.1 mV , 4 V ± (0.8% + 1) @ 0.001 V , 40 V ± (0.8% + 3) @ 0.01 V , 400 V ± (0.8% + 3) @ 0.1 V , 600 V ± (1% + 3) @ 1 V | ... |
Housing: | ... | Plastic |
"Index of Protection": | ... | IP20 |
Color: | ... | Green |
Operation temp: | ... | -20 °C ... 55 °C |
AC voltage measurement: | 4 V ± (1.2% + 5) @ 0.001 V , 40 V ± (1.2% + 5) @ 0.01 V , 400 V ± (1.2% + 5) @ 0.1 V , 600 V ± (1.5% + 5) @ 1 V | ... |
DC current measurement: | 40 A ± (2% + 3) @ 0.01 A , 400 A ± (2% + 3) @ 0.1 A | ... |
AC current measurement: | 40 A ± (2.5% + 5) @ 0.01 A , 400 A ± (2.5% + 5) @ 0.1 A | ... |
Resistance measurement: | 400 Ω ± (1.2% + 2) @ 0.1 Ω , 4 kΩ ± (1% + 2) @ 0.001 kΩ , 40 kΩ ± (1% + 2) @ 0.01 kΩ , 400 kΩ ± (1% + 2) @ 0.1 kΩ , 4 MΩ ± (1.2% + 3) @ 0.001 MΩ , 40 MΩ ± (2% + 5) @ 0.01 MΩ | ... |
Capacitance measurement: | 40 nF ± (4% + 25) @ 0.01 nF , 400 nF ± (4% + 5) @ 0.1 nF , 4 µF ± (4% + 5) @ 0.001 µF , 40 µF ± (4% + 5) @ 0.01 µF , 400 µF ± (4% + 5) @ 0.1 µF , 4 mF ± (10%) @ 0.001 mF 40 mF @ 0.01 mF | ... |
Inductance measurement: | | ... |
Frequency measurement: | 10 Hz ... 1 MHz ± (0.1% + 4) @ 0.01 Hz ... 1 kHz ± (0.1% + 4) | ... |
Temperature measurement: | °C -40 ... 40 °C ± (3% + 5) @ 1 °C 40 ... 400 °C ± (3% + 5) @ 1 °C 400 ... 1000 °C ± (1% + 3) @ 1 °C, °F -40 ... 104 °F ± (3% + 10) @ 1 °F 104 ... 752 °F ± (3% + 10) @ 1 °F 752 ... 1832 °F ± (2% + 10) @ 0.1 °F | ... |
Automatic change of measuring ranges: | | ... |
Diode test: | | ... |
Sound signal of the continuity test: | | ... |
RS-232: | | ... |
USB: | | ... |
Main features: | True RMS - accurate measurement of the RMS current and voltage for any waveform, NCV - electric field detection function, REL - relative measurement mode, Writing the value MAX / MIN, Hold - stopping the meter reading, Flashlight built-in, Large, readable LCD display with backlight, Low battery level alarm, Aesthetic and solid construction, The set includes a practical case | Control from a Web browser, Local control by physical button, schedule, timer, remote access, voice control, Possibility to manually program scenarios from the built-in API, SMA RP connector for an external antenna |
Power supply: | 3 x 1.5V, type AAA/LR03 battery - included | ... |
Weight: | 0.24 kg | 0.039 kg |
Dimensions: | 221 x 71 x 41 mm | 57 x 47 x 20 mm |
Manufacturer / Brand: | UNI-T | ZAMEL |
Guarantee: | 2 years | 2 years |