- Show All - Show differences - Back | INSULATION RESISTANCE METER UT-511 UNI-T | STYROFOAM PLUG FISCHER FID-50 |
| | |
| 148.06 EUR 148.06 EUR
| 0.82 EUR 0.82 EUR
|
Length: | ... | 50 mm |
Diameter: | ... | Ø 25 mm |
Thickness of the Styrofoam: | ... | ≥ 50 mm |
Diameter of the screw: | ... | Ø 4.5 mm / Ø 5 mm |
Resistance measurement: | Test voltage 100 V : 0.1 MΩ ... 500 MΩ Test voltage 250 V : 0.5 MΩ ... 1.99 GΩ Test voltage 500 V : 1 MΩ ... 3.99 GΩ Test voltage 1000 V : 2 MΩ ... 10 GΩ | ... |
Measuring accuracy: | 100 kΩ ... 100 MΩ ± (3% + 5) > 100 MΩ ± (5% + 5) | ... |
Open circuit voltage: | Test voltage + 20 % | ... |
Test current: | 1 mA ... 1.2 mA @ 100 kΩ / 100 V 1 mA ... 1.2 mA @ 250 kΩ / 250 V 1 mA ... 1.2 mA @ 500 kΩ / 500 V 1 mA ... 1.2 mA @ 1 MΩ / 1000 V | ... |
Short-circuit current: | ~ 2 mA | ... |
AC voltage measurement: | 30 V ... 750 V ± (2% + 3) @ 1 V | ... |
DC voltage measurement: | 30 V ... 1000 V ± (2% + 3) @ 1 V | ... |
Automatic change of measuring ranges: | | ... |
RS-232: | | ... |
USB: | | ... |
Main features: | Bargraf, Possibility to perform a comparative measurement, Warning of using high voltage during the measurement, Polarization index measurement (PI), Maximum duration of the measurement: 30 min, Save to 18 measurement results in the device memory, Large, readable LCD display with backlight, Low battery level alarm, Aesthetic and solid construction | ... |
Operation temp: | 0 °C ... 40 °C | ... |
Permissible relative humidity: | ≤ 85 % (non-condensing) | ... |
Power supply: | 8 x 1.5V, type R14/LR14 battery - included, 15 V DC / 600 mA (power adapter not included) | ... |
Weight: | 0.92 kg | 0.004 kg |
Dimensions: | 202 x 155 x 91 mm | ... |
Manufacturer / Brand: | UNI-T | ... |
Guarantee: | 2 years | 2 years |