![](img/compere_shop_all.png) - Show All ![](img/compere_shop_identical.png) - Show differences - Back | ![](img/eclose_grey.png) ACCESS CONTROLLER ASC2104B-T DAHUA | ![](img/eclose_grey.png) ACCESS CONTROLLER MODULE MC16-PAC-ST-2 ROGER | ![](img/eclose_grey.png) ACCESS CONTROLLER ASC2202B-D DAHUA |
| ![ASC2104B-T Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/asc2104b-t_m.jpg) | ![MC16-PAC-ST-2 Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/mc16-pac-st-2_m.jpg) | ![ASC2202B-D Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/asc2202b-d_m.jpg) |
| 197.57 EUR 197.57 EUR
| 334.09 EUR 334.09 EUR
| 266.55 EUR 266.55 EUR
|
Number of served transitions: | 4 (two-way) | 2 (two-way) | 2 (two-way) |
Support: | DAHUA ASC2204C-H | ... | DAHUA |
Number of supported readers: | 4 pcs | 8 | 4 pcs |
Number of users: | ... | unlimited (purchase of the appropriate license required) | ... |
Number of media per ID: | ... | 8 - Proximity card, PIN code, fingerprint, etc. | ... |
Output lines: | 5 pcs - Relay | ... | 4 pcs - Relay |
Buffer memory: | ... | 8 000 000 events buffer | ... |
Alarm inputs / outputs: | 1 / 1 | ... | ... |
Number of access zones: | ... | 4 | ... |
Number of alarm zones: | ... | 4 | ... |
Battery backup support: | | 12 V / 7 Ah | |
Communication: | RS-485, Wiegand 34/26, Control panel CAN (Controler Area Network) | Ethernet - RJ-45 socket RACS 5 v2 (Roger) RS-485 interface | RS-485, Ethernet, Wiegand |
Default IP address: | ... | ... | 192.168.0.2 |
Default admin user / password: | ... | ... | admin / - The administrator password should be set at the first start |
Main features: | 20 000 indexed users History of 30 000 events Function to prevent of multiple use of the same code/card to gain access (anti-passback) Door Left Open and Door Forced Open alarms Watchdog built-in Possibility to mount on a wall, or on the DIN TS-35 rail | Integrated support in VISO ST software Functions in the VISO ST system: - MSSQL database - work in distributed systems - multi-station work - monitoring of transitions with video preview - T&A event reporting - maximum number of transitions in the system : 128 | 100000 indexed users History of 500000 events Remote programming from PC Function of protection against multiple use of the same card for access (anti-passback) Counter of the door opening time with the possibility of sending an alarm signal after exceeding the set value Automatic sending of alarm messages to the SmartPSS system or after entering a code, card or fingerprint defined as door opening under duress Possibility to mount on a wall, or on the DIN TS-35 rail |
Power supply: | 12 V DC / 1 A | 17 ... 22 V AC 10 ... 15 V DC 22 ... 26 V DC | PoE (802.3af), 12 V DC / 1.4 A |
Operation temp: | -30 °C ... 60 °C | 5 °C ... 40 °C | -30 °C ... 60 °C |
Permissible relative humidity: | max. 95 % (non-condensing) | 10 % ... 95 % (non-condensing) | max. 95 % (non-condensing) |
Weight: | 0.384 kg | 0.14 kg | 0.4 kg |
Dimensions: | 209 x 117 x 51 mm | 175 x 72 x 30 mm | 210 x 106 x 50 mm |
Manufacturer / Brand: | DAHUA | ROGER | DAHUA |
Guarantee: | 3 years | 3 years | 3 years |