TopProducts Comparison
- Show All
- Show differences
- Back

PLUG-IN MODULE FOR OVERVOLTAGE LIMITER LE-412302 1+2 TYPE 50 kA LEGRAND


COAXIAL CABLE TCC-113-TRISHIELD


UPS AT-UPS850-PLUS 850 VA EAST


UPS UT1050EG-FR/UPS 1050 VA CyberPower


UPS ROUTERUPS-30 30 W 5 V / 9 V / 12 V DC IPS


POWER DISTRIBUTION UNIT ACAR-504/WF/RACK

48.15 EUR
48.15 EUR

0.45 EUR
0.45 EUR

85.42 EUR
85.42 EUR

144.73 EUR
144.73 EUR

43.95 EUR
43.95 EUR

36.34 EUR
36.34 EUR

Nominal power:  ...  ...  510 W  630 W  30 W  ...  
Rated voltage:  230 / 400 V AC, 50 / 60 Hz  ...  ...  ...  ...  230 V AC  
Rated current:  ...  ...  ...  ...  ...  10 A (total)  
Apparent Power:  ...  ...  850 VA  1050 VA    ...  
Response time:  ...  ...  ...  ...  ...  < 25 ns  
Input voltage:  ...  ...  165 V ... 275 V AC  165 V ... 290 V AC  100  ... 240 V AC  ...  
In section:  ...   100 m . Price for 1m when buying a whole roll  ...  ...  ...  ...  
Maximal voltage:  320 V AC, 50 / 60 Hz  ...  ...  ...  ...  ...  
Nominal voltage of surge suppressor:  ...  ...  ...  ...  ...  250 V / 50 Hz  
Input frequency:  ...  ...  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz  ...  
Protection level of surge suppressor:  ...  ...  ...  ...  ...  ≤ 1.3 kV (L/N)  
Inner conductor:  ...  Ø 1.13 mm Cu Wire  ...  ...  ...  ...  
Class:  1+2 type ( Class B+C )  ...  ...  ...  ...  ...  
Nominal stroke current:  ...  ...  ...  ...  ...  2.5 kA (L/N) - 8/20 µs  
Dielectric:  ...  Ø 4.8 mm (physical foam)  ...  ...  ...  ...  
Output voltage:  ...  ...  230 V AC ± 10 % (Approximated Sine Wave)  230 V AC ± 10 % (Approximated Sine Wave)  5 V / 9 V / 12 V DC  ...  
Shield:  ...  Double Al/PET  ...  ...  ...  ...  
Protection level Up :  1.2 kV @ 10/350 µs (T1)
1.7 kV @ 8/20 µs (T2)  
...  ...  ...  ...  ...  
Output frequency:  ...  ...  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  ...  ...  
Leak current:  ...  ...  ...  ...  ...  < 0.5 mA  
Transfer time:  ...  ...  ≤ 10 ms  4 ms  ...  ...  
Number of outlets:  ...  ...  ...  ...  ...  5 grounded outlets 10A/250V  
Typical battery charge time:  ...  ...  ...  6 hours  ...  ...  
Charging time (recover to 90% capacity):  ...  ...  8 hours  ...  ...  ...  
Switch:  ...  ...  ...  ...  ...  two-way, with light indication  
Nominal discharge current :  8 kA @ 10/350 µs (T1)
20 kA @ 8/20 µs (T2)  
...  ...  ...  ...  ...  
Length of the cable:  ...  ...  ...  ...  ...  2.7 m  
Braid:  ...  144  x 0.12 mm Al wire / PET  ...  ...  ...  ...  
Outer coating:  ...  Ø 6.8 mm PVC  ...  ...  ...  ...  
Maximum stroke current:  50 kA @ 8/20 µs (T2)  ...  ...  ...  ...  6.5 kA (L/N) - 8/20 µs  
Battery:  ...  ...  1 pcs - 12V/8Ah  ...  4 pcs Li-Ion - 3.7 V / 2.2 Ah  ...  
Coating color:  ...  White  ...  ...  ...  ...  
Impedance:  ...  75 Ω  ...  ...  ...  ...  
Screening efficiency:  ...  > 95 dB  ...  ...  ...  ...  
Housing:  Plastic  ...  ...  ...  ...  RACK 19", 1U, Plastic - non-flammable  
Estimated battery operation time:  ...  ...  
  • 23 minutes @ 100 W,
  • 5 minutes @ 300 W,
  • 2 minutes @ 500 W  
  • 65 minutes @ 60 W,
  • 43 minutes @ 90 W,
  • 14 minutes @ 200 W  
  • ...  ...  
    Number of outputs:  ...  ...  6 pcs CEE 7/3 (Schuko)  4 pcs  
  • 1 x USB-A socket,
  • 1 x 2.1/5.5 mm socket - 5 V,
  • 1 x 2.1/5.5 mm socket - 9 / 12 V (switchable)  
  • ...  
    Maximal outputs load:  ...  ...  ...  ...  
  • 2 A @ 5 V USB
  • 2 A @ 5 V (2.1/5.5mm socket)
  • 2 A @ 9 V (2.1/5.5mm socket)
  • 2 A @ 12 V (2.1/5.5mm socket)  
  • ...  
    Cable attenuation at 100m section:  ...  6.2 dB @ 50 MHz
    9.1 dB @ 230 MHz
    14.1 dB @ 470 MHz
    19.2 dB @ 860 MHz
    20.2 dB @ 1000 MHz
    24.8 dB @ 1350 MHz
    28.1 dB @ 1750 MHz
    31.8 dB @ 2000 MHz
    32.7 dB @ 2150 MHz  
    ...  ...  ...  ...  
    Operation state indication:    ...  
  • LED diodes,
  • Sound signaling  
  • LED diodes,
  • Sound signaling  
  • LED diodes : Status, 9V output, 12V output, Battery charging 25 % / 50 % / 75 % / 100 %  ...  
    Protections:  ...  ...  
  • Fuse
  • Overvoltage
  • Overload protection
  • Overcharge protection
  • Telephone line filter  
  • Overvoltage
  • Overload protection
  • Overcharge protection
  • Protection: DSL / Tel / FAX / Modem - RJ11 / RJ45  
  • Overload
  • Discharge
  • Short-circuit  
  • ...  
    Main features:  Varistor  ...  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Configurable alarm  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • Compatible with power generators
  • Built-in EMI, RFI filter
  • Configurable alarm  
  • Auto restart while AC is recovering
  • COLD START: - Cold start of the power adapter
  • Overload signaling
  • Battery charging indication  
  • ...  
    Application:  ...  ...  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Router / Access Point / Switch
  • Charging the devices, eg. smartphones, etc.
  • CCTV cameras  
  • ...  
    Housing type:  ...  ...  Desktop  Tower  Desktop  ...  
    Operation temp. / Relative humidity:  ...  ...  0 °C ... 40 °C / 20  ... 90 %  0 °C ... 40 °C / 0  ... 90 %  0 °C ... 40 °C / 20  ... 90 %  ...  
    Weight:  0.098 kg  ...  5.6 kg  6.79 kg  0.38 kg  0.59 kg  
    Dimensions:  62  x 54  x 17 mm  ...  280  x 185  x 95 mm  95  x 220  x 307 mm  160  x 105  x 28 mm  383  x 58  x 55 mm  
    Manufacturer / Brand:  LEGRAND  ...  EAST  CyberPower  IPS  ...  
    Guarantee:  2 years  2 years  2 years  2 years  2 years  2 years