![](img/compere_shop_all.png) - Show All ![](img/compere_shop_identical.png) - Show differences - Back | ![](img/eclose_grey.png) ACCESS CONTROLLER PR311SE-BK ROGER | ![](img/eclose_grey.png) ACCESS CONTROLLER ASC3202B DAHUA | ![](img/eclose_grey.png) ACCESS CONTROLLER MODULE MC16-PAC-ST-1 ROGER | ![](img/eclose_grey.png) BRANCH JUNCTION BOX WITH CABLE GLANDS LUX-158X118/EPN IP55 Elektro-Plast |
| ![PR311SE-BK Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/pr311se-bk-g_m.jpg) | ![ASC3202B Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/asc3202b_m.jpg) | ![MC16-PAC-ST-1 Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/mc16-pac-st-1_m.jpg) | ![LUX-158X118/EPN Click on the picture to see a detailed description](https://sklep.delta.poznan.pl/shop_image/product/lux-158x118_epn_m.jpg) |
| 108.47 EUR 108.47 EUR
| 501.60 EUR 501.60 EUR
| 248.27 EUR 248.27 EUR
| 4.88 EUR 4.88 EUR
|
Cards support: | Unique EM 125kHz | ... | ... | ... |
Number of intakes: | ... | ... | ... | 6 pcs Ø 29 mm |
Reading distance of prox-keys: | max. 15 cm | ... | ... | ... |
Number of served transitions: | ... | 2 | 1 (two-way) | ... |
Support: | ... | Cooperation with the access control systems | ... | ... |
Voltage insulation: | ... | ... | ... | 400 V |
Keyboard built-in: | | ... | ... | ... |
Number of supported readers: | ... | 2 pcs RS-485, 2 pcs Wiegand | 4 | ... |
Number of users: | ... | ... | unlimited (purchase of the appropriate license required) | ... |
Selected features of the standalone mode: | 1000 indexed users Operation with XM-2 I/O extension module (Full Standalone Mode) | ... | ... | ... |
Number of media per ID: | ... | ... | 8 - Proximity card, PIN code, fingerprint, etc. | ... |
Alarm inputs / outputs: | ... | 2 / 2 | ... | ... |
Buffer memory: | ... | ... | 8 000 000 events buffer | ... |
"Index of Protection": | ... | ... | ... | IP55 |
Number of access zones: | ... | ... | 2 | ... |
Number of alarm zones: | ... | ... | 2 | ... |
Material: | ... | ... | ... | Plastic - Polypropylene |
Battery backup support: | ... | | 12 V / 7 Ah | ... |
Internal dimensions: | ... | ... | ... | 147 x 108 x 86 mm |
Communication: | RS-485 RACS (Roger) | 3 x RS-485, 2 x Wiegand 34/26, 1 x Ethernet 10 / 100 Mbps (RJ-45) | Ethernet - RJ-45 socket RACS 5 v2 (Roger) RS-485 interface | ... |
Network protocols: | ... | P2P, IPv4, DNS, DDNS, TCP, UDP, ONVIF CGI | ... | ... |
Operation modes: | ... | Main control mode Sub control mode | ... | ... |
Average current consumption: | 50 mA | ... | ... | ... |
Main features: | The ability to add additional reader (bilateral way door control), 3 programmable input lines NO/NC, 2 programmable transistor outputs 1A, One programmable relay output 1.5A/30V, Door modes (Normal, Locked, Unlocked and Conditionally Unlocked), Any topology of communication bus, "Guest" type additional users support defined individually on each controller, Integration with an alarm system via in/out line , | Support for 2 doors (2x door sensor, 2x exit button, 2x alarm line, 2x lock control) 1000 indexed users Support up to 3000 finger prints Memory of 5000 RFID cards Support storage of 300 000 records 128 General Purpose Schedules Identification modes : RFID card, remote access, PIN, Fingerprint - Any combination of the above Tamper protections Automatic sending of alarm messages to the SmartPSS system or after entering a code, card or fingerprint defined as door opening under duress Counter of the door opening time with the possibility of sending an alarm signal after exceeding the set value Beep signal - Buzzer White list, Black list Web-Server built-in Software update via network Monitoring and configuration through network - SmartPSS Lite application Power output 12 V DC / 1 A - supplying power to the lock Support hardware I/O port configuration and export configuration diagrams ONVIF compliance | Integrated support in VISO ST software Functions in the VISO ST system: - MSSQL database - work in distributed systems - multi-station work - monitoring of transitions with video preview - T&A event reporting - maximum number of transitions in the system : 128 | 650 °C flammability index Screwed cover with screws There are cable glands in the housing Possibility of sealing Compliance with PN-IEC-60998-1:2006 standards |
Power supply: | 10 ... 15 V DC | 12 V DC / 2.5 A PoE (802.3at) | 17 ... 22 V AC 10 ... 15 V DC 22 ... 26 V DC | ... |
Power consumption: | ... | ≤ 2 W (standby) max. 20.4 W @ 12 V (operation) max. 14.4 W @ PoE (operation) | ... | ... |
Housing: | ... | Plastic (PC + ABS) | ... | ... |
Color: | ... | White | ... | White (RAL 9003) |
IK rating: | ... | IK06 | ... | ... |
Operation temp: | -25 °C ... 60 °C | -10 °C ... 55 °C | 5 °C ... 40 °C | ... |
Permissible relative humidity: | 10 ... 95 % (non-condensing) | 5 % ... 95 % (non-condensing) | 10 % ... 95 % (non-condensing) | ... |
Weight: | 0.18 kg | 0.72 kg | 0.14 kg | ... |
Dimensions: | 152.5 x 46 x 23 mm (Standard housing stand) 152.5 x 46 x 35 mm (Thicker housing stand) | 186 x 186 x 58 mm | 175 x 72 x 30 mm | 158 x 118 x 94 mm |
Manufacturer / Brand: | ROGER | DAHUA | ROGER | Elektro-Plast |
Guarantee: | 3 years | 3 years | 3 years | 2 years |