Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 2 grounded outlets 10A/250V ;
It protects symmetric video transmitting lines without any loss of the signal quality; Standard: AHD - 5 Mpx, HD-CVI - 8 Mpx 4K UHD, HD-TVI - 5 Mpx, CVBS - PAL / NTSC ; Threshold voltage: > 2.4 V (wire/wire) > 18.4 V (wire/ground) ; Maximum stroke current: 30 A (t=8.3ms) ; Reaction time: 15 ns ;
It is designed to protect the video devices, with differential (symmetric) video signal transmission or Ethernet 10/100 network devices; Threshold voltage: > 2.4 V ; Maximum stroke current: 5 kA (8/20µs) ; Protection level: 700 V (1000V/uS) ; Bandwidth: 0 ... 160 MHz ; Number of channels: 4 ;
It protects a connected device against lighting discharges effects; Threshold voltage: > 2.4 V (wire/wire) ; Maximum stroke current: 5 kA ; Bandwidth: 0 ... 140 MHz ; Response time: 15 ns ; Number of channels: 16 ;
The AXON-VIDEO-TWIST is designed to overvoltage protection of analog cameras and DVRs with analog signal inputs in CCTV systems, which use twisted-pair cable to video signal transmission; Rated voltage: 6 V ; Nominal discharge current line-PG [C2]: 5 kA - 8/20 µs ; Voltage protection level line-PG [C2]: ≤ 1000 V - 1.2 kV / 50 µs ; Bandwidth: 0 MHz ... 30 MHz ;
Threshold voltage (wire-wire): > 8.2 V ; Treshold voltage (wire / ground): > 19.4 V ; Reaction time: 15 ns ; Maximal stroke current RS-485 (t=8.3ms): 30 A ;
It is designed to overvoltage protection of devices connected to ADSL telecomunication lines - it is perfect protection of ADSL modems; Nominal voltage (line-line): 120 V ; Protection level of surge suppressor: ≤ 600 V ; Nominal discharge current (line-PG): 5 kA (8/20µs) ; Maximal discharge current (line-PG): 10 kA (8/20µs) ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks - protects 4 pairs of UTP cable; Rated voltage: 5 V ; Protection level: 1000 V ; Nominal stroke current: 2.5 kA (8/20µs) ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks - protects 4 pairs of UTP cable; Rated voltage: 120 V ; Housing: DIN, TS-35 rail mounting ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks - protects 4 pairs of UTP cable; Rated voltage: 120 V ; Voltage protection level line-PG: 1000 V (1.2/50µs) ; Nominal discharge current (line-PG): 2 kA (8/20µs) ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks - protects 4 pairs of UTP cable; Number of channels: 4 ; Rated voltage: 5 V ; Voltage protection level (line-line): ≤ 40 V - 1 kV/µs [C3] ; Voltage protection level line-PG: ≤ 600 V - 1 kV/µs [C3] ; Nominal discharge current (line-line): 20 A - 10/1000 µs [C3] ; Nominal discharge current (line-PG): 20 A - 10/1000 µs [C3] ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks - protects 4 pairs of UTP cable; Rated voltage: 20 V ; Voltage protection level (line-line): ≤ 40 V ; Voltage protection level line-PG: ≤ 600 V ; Nominal discharge current (line-line): 100 A (8/20µs) ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks and powered remotely in PoE+ technology - protects 4 pairs of UTP cable; Number of channels: 4 ; Rated voltage: 120 V ; Voltage protection level line-PG [C2]: ≤ 1000 V - 1.2/50 µs ; Nominal discharge current line-PG [C2]: 2 kA - 8/20 µs ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks and powered remotely in PoE+ technology - protects 4 pairs of UTP cable; Number of channels: 1 ; Rated voltage: 120 V ; Voltage protection level line-PG [C2]: ≤ 1000 V - 1.2/50 µs ; Nominal discharge current line-PG [C2]: 2 kA - 8/20 µs ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks - protects 4 pairs of UTP cable; Rated voltage: 5 V ; Voltage protection level (line-line): ≤ 40 V ; Voltage protection level line-PG: ≤ 600 V ; Nominal discharge current (line-line): 100 A (8/20µs) ;
In particular, the protector is designed to protect IP cameras powered remotely in PoE technology, i.e. through unused pairs of wires in the transmission cable; Number of channels: 4 ; Voltage protection level line-line: ≤ 40 V - 1 kV/µs [C3] ; Voltage protection level line-PG: ≤ 600 V - 1 kV/µs [C3] ; Nominal power voltage: 50 V ; Nominal current: 400 mA ; Voltage protection level line-line for power: ≤ 95 V - 1 kV/µs [C3] ; Voltage protection level line-PG for power: ≤ 1000 V - 1.2/50 µs [C2] ;
A limiter designed to protect devices connected to the Ethernet 10/100/1000 Mb/s network, including devices powered by PoE; Voltage protection level (line-line): 8 V ; Voltage protection level for power (line-line): 65 V PoE ; Voltage protection level line-PG: 400 V ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100 Mb/s networks - protects 2 pairs of UTP cable; Number of channels: 1 ; Nominal voltage (line-ground): 90 V DC ; Voltage protection level line-PG: ≤ 600 V ; Nominal discharge current (line-PG): 100 A - 8/20 µs ; Manufacturer / Brand: EWIMAR ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks and powered remotely in PoE+ technology - protects 4 pairs of UTP cable; Number of channels: 1 ; Nominal voltage (line-ground): 90 V ; Voltage protection level line-PG: ≤ 600 V ; Nominal discharge current (line-PG): 100 A - 8/20 µs ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks and powered remotely in PoE+ technology - protects 4 pairs of UTP cable; Number of channels: 4 ; Nominal voltage (line-ground): 90 V ; Voltage protection level line-PG: ≤ 600 V ; Nominal discharge current (line-PG): 100 A - 8/20 µs ; Manufacturer / Brand: EWIMAR ;
A limiter designed to protect devices connected to the Ethernet 10/100 Mb/s network, including devices powered by PoE; Rated voltage: 5 V ; Voltage protection level (line-line): 40 V ; Voltage protection level line-PG: 600 V ; Nominal power voltage: 0 ... 50 V ; Voltage protection level for power (line-line): 125 V ;
It is designed to overvoltage protection of Ethernet 10/100 Mb/s network devices connected to it and powered remotly with PoE technology; Rated voltage: 5 V ; Voltage protection level line-line: 40 V - 1 kV/µs ; Voltage protection level line-PG: 600 V - 1 kV/µs ; Nominal power voltage: 50 V ; Nominal current: 400 mA ; Number of channels: 4 ;
It is designed to overvoltage protection of Ethernet 10/100 Mb/s network devices connected to it and powered remotly with PoE technology; Rated voltage: 5 V ; Voltage protection level line-line: ≤ 40 V - 1 kV/µs ; Voltage protection level line-PG: ≤ 600 V - 1 kV/µs ; Nominal power voltage: 50 V ; Nominal current: 400 mA ; Number of channels: 12 ;
Device is designed to overvoltage protection of devices connected to the Ethernet 10/100/1000 Mb/s networks, powered remotely by unused pairs of wires; Rated voltage: 5 V ; Voltage protection level line-line: ≤ 40 - 1 kV/µs ; Voltage protection level line-PG: ≤ 600 - 1 kV/µs ; Nominal discharge current (line-line): 20 A (10/1000µs) ; Nominal power voltage: 50 V ;
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V 2 non-grounded outlets 2.5A/250V ;
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 16 A ; Maximal total load: 3680 W ; Number of outlets: 6 grounded outlets 16A/250V ;
It is designed to Speed Dome cameras overvoltage protection. The device protects: Video line (symetric or asymmetric signal), RS-485 line, DC 12V power line or AC 24V power line;
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ; Housing: RACK 19", 1U ;
Net:
0.00
EUR
Gross:
0.00
EUR
Weight:
0.00
kg
This site uses cookies. More information about using by us cookie files, their usage and how to modify the acceptance of cookie files, can be found by pressing
link