PK1-24-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 83.87 SEK  Gross: 103.16 SEK
PK1-24-ZN
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
Net: 69.59 SEK  Gross: 85.60 SEK
PK4-24-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 262.43 SEK  Gross: 322.79 SEK
ARM7011-W2(868)
Number of relay outputs: ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Wireless: 868 MHz - Bidirectional communication, Range : 1200 m (in open area) ; Main features: LED indication, alarm input - Tamper signaling ;
Net: 602.61 SEK  Gross: 741.21 SEK
DS-PM1-O1L-WE
Number of relay outputs: ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Main features: Wireless 868 MHz, LED indication, alarm input ;
Net: 577.62 SEK  Gross: 710.47 SEK
RD-8
The Modbus RD-8 digital output module has 8 transistor outputs; The outputs can take two states: ground potential or power input potential; PTZ control: RS-485 ; Current efficiency: 2 A (single output), 8 A (total) ; Inputs protection;
Net: 345.24 SEK  Gross: 424.65 SEK
2R-D7
PTZ control: RS-485 / UART TTL ; Protocol: Modbus RTU ; Transmission speed: 4800 / 9600 / 19200 b/s ; Number of relay outputs: 2 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 111.02 SEK  Gross: 136.55 SEK
4R-D7
PTZ control: RS-485 / UART TTL ; Protocol: Modbus RTU ; Transmission speed: 4800 / 9600 / 19200 b/s ; Number of relay outputs: 4 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 142.18 SEK  Gross: 174.88 SEK
ESP12-2R-D8
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 2 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 128.85 SEK  Gross: 158.49 SEK
ESP12-4R-MV
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 4 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 171.42 SEK  Gross: 210.85 SEK
ESP12-8R-D8
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of inputs: ; Number of relay outputs: 8 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 244.38 SEK  Gross: 300.59 SEK
AWZ-517
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 20 ... 32 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x REL-C/NO/NC ; Main features: 5/20mm delayed fuse 6.3 A ;
Net: 91.64 SEK  Gross: 112.72 SEK
OR-PI-456/24UC
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 V DC / AC ; Relay maximal load: 16 A / 250 V AC ; Output: 1 x NO/NC ; Manufacturer / Brand: ORNO ;