Top Access Control  Access Control Panels and Controllers  Without keypad
Compare category Description:Sort:type | price | price a A A

Without keypad

ATLO-FR-601
Face recognition distance: 0.5 m ... 1 m ; RFID proximity reader built-in: Unique EM 125kHz ; Fingerprint reader built-in: Memory of 600 fingerprint patterns ; Wiegand interface; Alarm inputs / outputs: 0 / 1 - Relay output ; Power supply: 12 V DC ;
Net: 1 188.77 CZK  Gross: 1 462.19 CZK
APTI-AI70FRTD-V2
Sensor: 1/2.8 " SONY Starvis™ Back-illuminated CMOS ; View angle: 68 ° ; Resolution: 1920 x 1080 ; Range of IR illumination: 5 m ; White light LED illuminator range: 5 m ; Temperature measurement range: 35 °C ... 42 °C ; Accuracy of temperature measurement: ± 0.3 °C ; Face recognition distance: 0.5 m ... 1.5 m (max 30 000 faces in the database) ; RS-485 interface; Wiegand interface; Alarm inputs / outputs: 0 / 2 ; Audio: Speaker built-in ; Power supply: 12 V DC ;
Net: 1 792.11 CZK  Gross: 2 204.30 CZK
APTI-AI71FRTD
The controller is equipped with a wall mounting bracket; Sensor: 1/2.8 " SONY Starvis™ Back-illuminated CMOS ; View angle: 68 ° ; Resolution: 1920 x 1080 ; Range of IR illumination: 5 m ; White light LED illuminator range: 5 m ; Temperature measurement range: 35 °C ... 42 °C ; Accuracy of temperature measurement: ± 0.3 °C ; Face recognition distance: 0.5 m ... 2.3 m (max 30 000 faces in the database) ; RS-485 interface; Wiegand interface; Alarm inputs / outputs: 0 / 2 ; Relay output: NO, NC ; Audio: Speaker built-in ; Power supply: 12 V DC ;
Net: 1 433.69 CZK  Gross: 1 763.44 CZK
APTI-AI80FQRTD
Sensor: 1/2.9 " GC2093 ; View angle: 66 ° ; Resolution: 1920 x 1080 ; Cards support: 13.56 MHz S50 ; Range of IR illumination: 5 m ; White light LED illuminator range: 5 m ; Temperature measurement range: 35.7 °C ... 42 °C ; Accuracy of temperature measurement: ± 0.3 °C ; Face recognition distance: 0.5 m ... 2.0 m (max 30 000 faces in the database) ; RS-485 interface; Wiegand interface; Alarm inputs / outputs: 0 / 1 ; Audio: Speaker built-in ; Power supply: 12 V / 2 A DC ;
Net: 1 433.69 CZK  Gross: 1 763.44 CZK
ASI7213X-T1
Resolution: 1920 x 1080 ; Range of IR illumination: 5 m ; White light LED illuminator range: 5 m ; Temperature measurement range: 30 °C ... 50 °C ; Accuracy of temperature measurement: ± 0.1 °C ; Face recognition distance: 0.3 m ... 1.8 m ; RFID proximity reader built-in: 13.56 MHz S50 ; RS-485 interface; RS-232 interface; Wiegand interface; USB: 2 x USB 2.0 ; Alarm inputs / outputs: 2 / 2 - Relay outputs ; Audio: Speaker built-in ; Power supply: 12 V DC ;
Net: 87 455.20 CZK  Gross: 107 569.90 CZK
ASA3213G-MW
Access controller with face recognition function; Resolution: 1920 x 1080 ; IR illuminator; LED illuminator; Face recognition distance: 0.3 m ... 1.5 m ; RFID proximity reader built-in: 13.56 MHz S50 ; Internal memory: Support storage of 150 000 records ; RS-485 interface; Alarm inputs / outputs: 1 / 1 ; Audio: Voice message ; Power supply: 12 V DC ;
Net: 11 947.43 CZK  Gross: 14 695.34 CZK
ACCO-NT
Inputs: 8 pcs ; Outputs: 8 pcs ; Events memory: Recording up to 1 000 000 events from the control panel, Max. 100 000 events read from each access control module ; Main features: Ability to block/unblock partition at a specified time, or as per access schedule, Up to 256 access calendars, weekly schedules, daily schedules, time frames ;
Net: 9 307.05 CZK  Gross: 11 447.67 CZK
ACCO-NT2
Inputs: 8 pcs ; Outputs: 8 pcs ; Events memory: Recording up to 1 000 000 events from the control panel, Max. 100 000 events read from each access control module ; Main features: Ability to block/unblock partition at a specified time, or as per access schedule, Up to 256 access calendars, weekly schedules, daily schedules, time frames ;
Net: 9 307.05 CZK  Gross: 11 447.67 CZK
CPR32-SE-BRD
Inputs: 8 pcs ; Outputs: 4 pcs ; Events memory: Non-volatile log buffer of the last 250 000 events ; Main features: Ability to block/unblock partition at a specified time, or as per access schedule, ;
Net: 3 882.97 CZK  Gross: 4 776.05 CZK
ACCO-KP2
Input lines: 12 ; Output lines: 12 ; Operation modes: Autonomous operation, Work in the ACCO/ACCO NET system ; Relay switching voltage: 250 V AC, 30 V DC ; Relay contacts load: 8 A ; Main features: Support for single door with entry and exit authorization, Possibility to add different privileges to the users Identification: Card and/or PIN, Dallas iButton ; Power supply: 12 V DC ;
Net: 2 706.09 CZK  Gross: 3 328.49 CZK
ASC2202B-D
Number of served transitions: 2 (two-way) ; Number of supported readers: 4 pcs ; Output lines: 4 pcs - Relay ; Communication: RS-485, Ethernet, Wiegand ; Power supply: PoE (802.3af), 12 V DC ;
Net: 6 624.85 CZK  Gross: 8 148.57 CZK
ASC2202B-S
Number of served transitions: 2 (one-way) ; Number of supported readers: 4 pcs ; Output lines: 2 pcs - Relay ; Communication: RS-485, Ethernet, Wiegand ; Power supply: PoE (802.3at), 12 V DC ;
Net: 5 298.69 CZK  Gross: 6 517.39 CZK
ASC2204B-S
Number of served transitions: 4 (one-way) ; Number of supported readers: 4 pcs ; Output lines: 5 pcs - Relay ; Communication: RS-485, Ethernet, Wiegand ;
Net: 7 270.01 CZK  Gross: 8 942.11 CZK
ASI1212F
Input lines: ; Output lines: ; RS-485 interface; Wiegand interface; Internal memory: Support storage of 150 000 records ; Main features: Built-in LCD display 240 x 320 px - 2.8 " capacitive touch screen Identification modes : Proximity identifier 13.56 MHz S50, Fingerprint, PIN, Any combination of the above ;
Net: 5 639.19 CZK  Gross: 6 936.20 CZK
MC16-PAC-EX-1
The MC16-PAC-EX-1 controller is a multifunctional electronic module, intended for use in the RACS 5 v2 system, which enables the implementation of access control of the transition and building automation; Number of served transitions: ; Inputs: ; Outputs: ; Number of login points: ; Number of access terminals: ; Number of access zones: ;
Net: 8 363.20 CZK  Gross: 10 286.74 CZK
MC16-PAC-EX-2
The MC16-PAC-EX-2 controller is a multifunctional electronic module, intended for use in the RACS 5 v2 system, which enables the implementation of access control of the transition and building automation; Number of served transitions: ; Inputs: 12 ; Outputs: ; Number of login points: ; Number of access terminals: ; Number of access zones: ;
Net: 12 724.01 CZK  Gross: 15 650.53 CZK
MC16-PAC-EX-3
The MC16-PAC-EX-3 controller is a multifunctional electronic module, intended for use in the RACS 5 v2 system, which enables the implementation of access control of the transition and building automation; Number of served transitions: ; Inputs: 18 ; Outputs: 12 ; Number of login points: ; Number of access terminals: 12 ; Number of access zones: ;
Net: 17 084.83 CZK  Gross: 21 014.34 CZK
MC16-PAC-ST-1
Number of served transitions: 1 (two-way) ; Number of supported readers: ; Buffer memory: 8 000 000 events buffer ; Communication: Ethernet ; Main features: Integrated support in VISO ST software ;
Net: 6 152.93 CZK  Gross: 7 568.10 CZK
MC16-PAC-ST-2
Number of served transitions: 2 (two-way) ; Number of supported readers: ; Buffer memory: 8 000 000 events buffer ; Communication: Ethernet ; Main features: Integrated support in VISO ST software ;
Net: 8 303.46 CZK  Gross: 10 213.26 CZK
MC16-PAC-ST-3
Number of served transitions: 3 (two-way) ; Number of supported readers: 12 ; Buffer memory: 8 000 000 events buffer ; Communication: Ethernet ; Main features: Integrated support in VISO ST software ;
Net: 10 454.00 CZK  Gross: 12 858.42 CZK
PR102DR
Relay contacts load: 1.5 A / 30 V ; Input lines: ; Output lines: ;
Net: 2 180.41 CZK  Gross: 2 681.90 CZK
PR102DR-BRD
Relay contacts load: 1.5 A / 30 V ; Input lines: ; Output lines: ;
Net: 2 060.99 CZK  Gross: 2 535.02 CZK
DS-K2604T
Number of supported readers: 8 pcs @ RS-485, 4 pcs @ Wiegand ; Battery backup support: max. 7 Ah ; Input lines: 4 pcs - Alarm inputs, 4 pcs - Reed switch , 4 pcs - Door/gate opening button, 9 pcs - Tamper ; Output lines: 4 pcs - Lock relay, 4 pcs - Relay ; Communication: RS-485, Ethernet, Wiegand (w26 / w34), Open Supervised Device Protocol (OSDP) ;
Net: 19 205.50 CZK  Gross: 23 622.77 CZK
DS-K1T341AM-S
Sensor: CMOS ; Resolution: 1280 x 720 ; Face recognition distance: 0.3 m ... 1.5 m ; RS-485 interface; Audio: Speaker built-in ; Main features: Port USB Recording of information about Time&Attendance ; Power supply: 12 V DC ;
Net: 11 941.46 CZK  Gross: 14 688.00 CZK
DS-K1TA70MI-T
Sensor: CMOS ; Resolution: 1920 x 1080 ; Sensor: Uncooled VOx microbolometer ; Matrix size: 120 x 160 px ; Temperature measurement range: 30 °C ... 45 °C ; Accuracy of temperature measurement: ± 0.5 °C ; Cards support: 13.56 MHz S50 ; Reading distance of prox-keys: ~ 5 cm ; Face recognition distance: 0.3 m ... 1.8 m ; IR illuminator; LED illuminator; RS-485 interface; Audio: Speaker built-in ; Power supply: 12 V DC ;
Net: 44 784.95 CZK  Gross: 55 085.49 CZK
PR311SE-BK
Reading distance of prox-keys: max. 15 cm ; Selected features of the standalone mode: 1000 indexed users ; Main features: The ability to add additional reader (bilateral way door control), Any topology of communication bus, ;
Net: 2 688.17 CZK  Gross: 3 306.45 CZK
PR312EM-BK-G
Reading distance of prox-keys: max. 15 cm ; Selected features of the standalone mode: 4000 indexed users, 32000 events buffer ; Main features: The ability to add additional reader (bilateral way door control), 3 programmable input lines NO/NC, Any topology of communication bus, 99 General Purpose Schedules, Identification modes (Card or PIN, Card and PIN, Card only, PIN only), System management via WAN/ LAN network, or COM/USB serial port ;
Net: 3 166.07 CZK  Gross: 3 894.27 CZK
PR621
Relay contacts load: 1.5 A / 30 V ; Input lines: ; Output lines: ; Main features: Unique EM 125kHz proximity reader built-in ;
Net: 2 658.30 CZK  Gross: 3 269.71 CZK
PR622-G
Cards support: Unique EM 125kHz ; Reading distance of prox-keys: max. 15 cm ; Relay contacts load: 1.5 A / 30 V ; Input lines: ; Output lines: ;
Net: 3 166.07 CZK  Gross: 3 894.27 CZK
CPR32-NET-BRD
Inputs: 8 pcs ; Outputs: 6 pcs ; Events memory: Recording up to 240 000 events from the control panel ; Main features: Ability to block/unblock partition at a specified time, or as per access schedule, ;
Net: 8 064.81 CZK  Gross: 9 919.72 CZK
ASC2102B-T
Number of served transitions: 2 (two-way) ; Number of supported readers: 4 pcs ; Output lines: 5 pcs - Relay ; Communication: RS-485, Wiegand 34/26, Control panel CAN (Controler Area Network) ;
Net: 4 330.94 CZK  Gross: 5 327.06 CZK
ASC2104B-T
Number of served transitions: 4 (two-way) ; Number of supported readers: 4 pcs ; Output lines: 5 pcs - Relay ; Communication: RS-485, Wiegand 34/26, Control panel CAN (Controler Area Network) ;
Net: 4 910.39 CZK  Gross: 6 039.78 CZK
ASC2202C-D
Number of served transitions: 2 (two-way) ; Number of supported readers: 4 pcs ; Battery backup support: max. 7 Ah ; Input lines: 12 pcs ; Output lines: 4 pcs - Relay ; Communication: 5x RS-485, Ethernet, 4x Wiegand 34/26 ;
Net: 14 551.97 CZK  Gross: 17 898.92 CZK
ASC2204C-H
Number of served transitions: 4 (one-way) ; Number of supported readers: 4 pcs ; Battery backup support: max. 7 Ah ; Input lines: 20 pcs ; Output lines: 12 pcs - Relay ; Communication: RS-485, Ethernet, Wiegand 34/26 ;
Net: 18 954.60 CZK  Gross: 23 314.16 CZK
ASC3202B
Number of served transitions: ; Number of supported readers: 2 pcs RS-485, 2 pcs Wiegand ; Alarm inputs / outputs: 2 / 2 ; Communication: RS-485, Wiegand 34/26, Ethernet ;
Net: 12 807.65 CZK  Gross: 15 753.41 CZK
MC16-PAC-EX-1-KIT
The MC16-PAC-EX-1-KIT access control kit is designed to support 1 door in the RACS 5 v2 ver. EX system; Number of served transitions: 1 (two-way) ; Number of supported readers: 4 pcs ; Battery backup support: max. 7 Ah ; Input lines: 8 pcs ; Output lines: 8 pcs ; Communication: RS-485, RACS 5 v2 (Roger), Wiegand ; Main features: Metal housing Power adapter : 24 V DC / 2.2 A, ;
Net: 10 902.03 CZK  Gross: 13 409.50 CZK
MC16-PAC-ST-1-KIT
The MC16-PAC-ST-1-KIT access control kit is designed to support 1 door in the RACS 5 v2 ver. ST system; Number of served transitions: 1 (two-way) ; Number of supported readers: ; Buffer memory: 8 000 000 events buffer ; Communication: Ethernet ; Main features: Metal housing Integrated support in VISO ST software ;
Net: 8 691.52 CZK  Gross: 10 690.57 CZK
MC16-PAC-ST-2-KIT
Number of served transitions: 2 (two-way) ; Number of supported readers: ; Buffer memory: 8 000 000 events buffer ; Communication: Ethernet ; Main features: Metal housing Integrated support in VISO ST software ;
Net: 13 112.31 CZK  Gross: 16 128.14 CZK
MC16-PAC-ST-3-KIT
Number of served transitions: 3 (two-way) ; Number of supported readers: 12 ; Buffer memory: 8 000 000 events buffer ; Communication: Ethernet ; Main features: Metal housing Integrated support in VISO ST software ;
Net: 16 278.38 CZK  Gross: 20 022.41 CZK
MC16-PAC-ST-4-KIT
Number of served transitions: 4 (two-way) ; Number of supported readers: 16 ; Buffer memory: 8 000 000 events buffer ; Communication: Ethernet ; Main features: Metal housing Integrated support in VISO ST software ;
Net: 18 428.43 CZK  Gross: 22 666.97 CZK