Top Power Supply  Relay Modules  12V DC
Compare category Description:Sort:type | price | price a A A

12V DC

PK-41F-1Z-C2-1/12V
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 150.08 NOK  Gross: 184.60 NOK
P-HF41F-012-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 46.96 NOK  Gross: 57.76 NOK
PK1-12-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 76.88 NOK  Gross: 94.56 NOK
PK1-12-ZN
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
Net: 63.87 NOK  Gross: 78.56 NOK
ARM7011-W2(868)
Number of relay outputs: ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Wireless: 868 MHz - Bidirectional communication, Range : 1200 m (in open area) ; Main features: LED indication, alarm input - Tamper signaling ;
Net: 599.45 NOK  Gross: 737.32 NOK
DS-PM1-O1L-WE
Number of relay outputs: ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Main features: Wireless 868 MHz, LED indication, alarm input ;
Net: 574.59 NOK  Gross: 706.75 NOK
PK1-12-PDT
The PK1-12-PDT module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: DIN, TS-35 rail mounting, ;
Net: 142.65 NOK  Gross: 175.46 NOK
PK1-12-PST
The PK1-12-PST module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: Screw mounting with spacers, ;
Net: 108.18 NOK  Gross: 133.06 NOK
PK2-12-PWT
Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: max. 2 x 10 A, 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: LED indication, Splash-proof casing ;
Net: 195.75 NOK  Gross: 240.77 NOK
PK4-12-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO/NC ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 246.57 NOK  Gross: 303.28 NOK
PK4-12-ZN/S
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Mounting with self-adhesive bases, Screw mounting with spacers Protections : Overvoltage, Reverse polarity connection ;
Net: 230.08 NOK  Gross: 283.00 NOK
PK4-12-ZW
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Protections : Overvoltage, Reverse polarity connection Splash-proof casing ;
Net: 182.76 NOK  Gross: 224.79 NOK
RD-8
The Modbus RD-8 digital output module has 8 transistor outputs; The outputs can take two states: ground potential or power input potential; PTZ control: RS-485 ; Current efficiency: 2 A (single output), 8 A (total) ; Inputs protection;
Net: 343.43 NOK  Gross: 422.42 NOK
2R-D7
PTZ control: RS-485 / UART TTL ; Protocol: Modbus RTU ; Transmission speed: 4800 / 9600 / 19200 b/s ; Number of relay outputs: 2 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 110.44 NOK  Gross: 135.84 NOK
ESP12-2R-D8
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 2 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 128.18 NOK  Gross: 157.66 NOK
ESP12-4R-MV
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 4 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 170.52 NOK  Gross: 209.74 NOK
ESP12-8R-D8
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of inputs: ; Number of relay outputs: 8 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 243.09 NOK  Gross: 299.00 NOK
AWZ-508
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 15 V DC, 21 ... 28 V DC (set by jumpers) ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - T+ / T- input LED indication ;
Net: 74.59 NOK  Gross: 91.75 NOK
AWZ-510
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC, 10 ... 13 V AC ; Relay maximal load: 1 A (max) 30 V DC / 50 V AC ; Output: 1 x NO/NC ;
Net: 49.72 NOK  Gross: 61.16 NOK
AWZ-511
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max) 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 93.92 NOK  Gross: 115.52 NOK
AWZ-512
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 77.35 NOK  Gross: 95.14 NOK
AWZ-513
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 0.5 A, 2 A ;
Net: 104.97 NOK  Gross: 129.11 NOK
AWZ-514
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
Net: 85.88 NOK  Gross: 105.63 NOK
AWZ-520
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 5 x NO/NC ;
Net: 149.17 NOK  Gross: 183.48 NOK
AWZ-529
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 69.06 NOK  Gross: 84.94 NOK
AWZ-622
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 1 x NO / NC ;
Net: 33.15 NOK  Gross: 40.77 NOK
AWZ-626
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 4 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
Net: 292.82 NOK  Gross: 360.17 NOK
B31
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 15 V DC - no polarization ; Relay maximal load: 2 A / 30 V ; Output: 1 x NO / NC ;
Net: 234.81 NOK  Gross: 288.82 NOK
MP-1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 2 x 4 A / 48 V DC/AC 2 x 8 A / 250 V DC / 400 V AC ; Output: 4x NO/NC ;
Net: 243.09 NOK  Gross: 299.00 NOK
PK-552
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Current consumption: 111 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
Net: 27.79 NOK  Gross: 34.18 NOK
UPK-1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V AC/DC ; Relay maximal load: 1 A @ 30 V AC/DC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 2 A ;
Net: 56.85 NOK  Gross: 69.93 NOK
UPK-2.1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 2 A @ 30 V AC / DC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 2 A ;
Net: 62.54 NOK  Gross: 76.92 NOK
UPK-2.2
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 1 A @ 30 V AC / DC ; Output: 2 x NO/NC ;
Net: 62.54 NOK  Gross: 76.92 NOK
OR-PI-457/1/UNI
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V ... 230 V AC / DC ; Relay maximal load: 16 A / 250 V AC ; Output: 1 x NO/NC ; Manufacturer / Brand: ORNO ;
Net: 245.88 NOK  Gross: 302.43 NOK
OR-PI-457/3/UNI
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V ... 240 V AC / DC ; Relay maximal load: 8 A / 250 V AC ; Output: 3 x NO/NC ; Manufacturer / Brand: ORNO ;
Net: 373.87 NOK  Gross: 459.86 NOK
AWZ-516
Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 10 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: EEPROM non-volatile memory, Time settings range 1 s ... 99 h, ;
Net: 295.58 NOK  Gross: 363.56 NOK
AWZ-525
Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max) @ 30 V DC / 50 V AC ; Output: 1 x NO/NC ; Main features: Time settings range 1. Range : 1 s ... 60 s, 2. Range : 5 s ... 5 minutes ;
Net: 168.51 NOK  Gross: 207.27 NOK
AWZ-526
Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max) @ 30 V DC / 50 V AC ; Output: 1 x NO/NC ; Main features: Time settings range 1. Range : 1 s ... 60 s, 2. Range : 5 s ... 5 minutes ;
Net: 174.03 NOK  Gross: 214.06 NOK
OR-PRE-452/UNI
Number of relay outputs: ; Power supply: 12 ... 230 V AC / DC ; Relay maximal load: 16 A 250 V AC 16 A 24 V DC ; Output: 1 x NO/NC ; Main features: Time settings range : 1 s / 10 s / 1 m / 10 m / 1 h / 10 h / 1 day / 10 days ;
Net: 446.63 NOK  Gross: 549.35 NOK
OR-PRE-453/UNI
Number of relay outputs: ; Power supply: 12 ... 230 V AC / DC ; Relay maximal load: 16 A 250 V AC 16 A 24 V DC ; Output: 1 x NO/NC ; Main features: Time settings range : 1 s / 10 s / 1 min / 10 min / 1 h / 10 h / 1 day / 10 days ;
Net: 446.63 NOK  Gross: 549.35 NOK