Top Electrical Installation Equipment  Residual Current Circuit Breakers
Compare category Description:Sort:type | price | price a A A

Residual Current Circuit Breakers

HNB-B16/1N/003
Device type: Residual Current Circuit Breaker, One-phase, AC type, B curve ; Rated sensitivity: 30 mA ; Rated current: 16 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1.5 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ;
Net: 52.47 AUD  Gross: 52.47 AUD
HNB-B20/1N/003
Device type: Residual Current Circuit Breaker, One-phase, AC type, B curve ; Rated sensitivity: 30 mA ; Rated current: 20 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1.5 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ;
Net: 66.98 AUD  Gross: 66.98 AUD
HNB-B25/1N/003
Device type: Residual Current Circuit Breaker, One-phase, AC type, B curve ; Rated sensitivity: 30 mA ; Rated current: 25 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1.5 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ;
Net: 68.13 AUD  Gross: 68.13 AUD
HNC-25/2/003
Device type: Residual current circuit breaker, AC type ; Rated sensitivity: 30 mA ; Rated current: 25 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1.5 mm² - 35 mm² or 2 x 16 mm² ; Housing: DIN, TS-35 rail mounting ;
Net: 43.98 AUD  Gross: 43.98 AUD
HNC-25/4/003
Device type: Residual current circuit breaker, Three-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 25 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1.5 mm² - 35 mm² or 2 x 16 mm² ; Housing: DIN, TS-35 rail mounting ;
Net: 58.95 AUD  Gross: 58.95 AUD
HNC-40/2/003
Device type: Residual current circuit breaker, AC type ; Rated sensitivity: 30 mA ; Rated current: 40 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1.5 mm² - 35 mm² or 2 x 16 mm² ; Housing: DIN, TS-35 rail mounting ;
Net: 43.98 AUD  Gross: 43.98 AUD
HNC-40/4/003
Device type: Residual current circuit breaker, Three-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 40 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1.5 mm² - 35 mm² or 2 x 16 mm² ; Housing: DIN, TS-35 rail mounting ;
Net: 58.84 AUD  Gross: 58.84 AUD
HNC-63/4/003
Device type: Residual current circuit breaker, Three-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 63 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1.5 mm² - 35 mm² or 2 x 16 mm² ; Housing: DIN, TS-35 rail mounting ;
Net: 75.46 AUD  Gross: 75.46 AUD
LE-402024
Device type: Residual current circuit breaker, One-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 25 A ; Number of poles: ; Breaking capacity: 10000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 41.29 AUD  Gross: 41.29 AUD
LE-402062
Device type: Residual current circuit breaker, Three-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 25 A ; Number of poles: ; Breaking capacity: 10000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 55.51 AUD  Gross: 55.51 AUD
LE-402063
Device type: Residual current circuit breaker, Three-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 40 A ; Number of poles: ; Breaking capacity: 10000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 55.58 AUD  Gross: 55.58 AUD
LE-410919
Device type: Residual Current Circuit Breaker, One-phase, AC type, B curve ; Rated sensitivity: 30 mA ; Rated current: 10 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 75.74 AUD  Gross: 75.74 AUD
LE-410921
Device type: Residual Current Circuit Breaker, One-phase, AC type, B curve ; Rated sensitivity: 30 mA ; Rated current: 16 A ; Number of poles: ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 75.71 AUD  Gross: 75.71 AUD
LE-411509
Device type: Residual current circuit breaker, One-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 25 A ; Number of poles: ; Breaking capacity: 10000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 49.48 AUD  Gross: 49.48 AUD
LE-411510
Device type: Residual current circuit breaker, One-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 40 A ; Number of poles: ; Breaking capacity: 10000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 56.83 AUD  Gross: 56.83 AUD
LE-411707
Device type: Residual current circuit breaker, Three-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 25 A ; Number of poles: ; Breaking capacity: 10000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 76.10 AUD  Gross: 76.10 AUD
LE-411708
Device type: Residual current circuit breaker, Three-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 40 A ; Number of poles: ; Breaking capacity: 10000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 78.86 AUD  Gross: 78.86 AUD
LE-411709
Device type: Residual current circuit breaker, Three-phase, AC type ; Rated sensitivity: 30 mA ; Rated current: 63 A ; Number of poles: ; Breaking capacity: 10000 A ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 79.30 AUD  Gross: 79.30 AUD