TopProducts Comparison
- Show All
- Show differences
- Back

UPS AT-UPS1200R-RACK 1200 VA EAST


UPS AT-UPS1500R-RACK 1500 VA EAST


UPS AT-UPS2000R-RACK 2000 VA EAST


UPS AT-UPS2000R/2-RACK 2000 VA EAST


UPS AT-UPS650R-RACK 650 VA EAST


UPS UPS14 RACK 2000 VA Green Cell


UPS VI-1000-RT/LCD 1000 VA


UPS VI-1500-RT/LCD 1500 VA


UPS AT-UPS1000BK-RACK 1000 VA EAST


UPS AT-UPS1000RT-RACK 1000 VA EAST


UPS AT-UPS1000RT/2-RACK 1000 VA EAST


UPS AT-UPS1500S-RT-RACK 1500 VA EAST


UPS AT-UPS2000RT-RACK 2000 VA EAST


UPS AT-UPS2000RT/2-RACK 2000 VA EAST


UPS AT-UPS2000RT/3-RACK 2000 VA EAST


UPS AT-UPS2000S-RT-RACK 2000 VA EAST


UPS AT-UPS3000R-RACK 3000 VA EAST


UPS AT-UPS3000RT-RACK 3000 VA EAST


UPS AT-UPS3000S-RT-RACK 3000 VA EAST


UPS VI-1000/R1U 1000 VA PowerWalker


UPS VI-2000-RT/LCD 2000 VA


UPS VI-3000-RT/LCD 3000 VA


UPS VI-500/R1U 500 VA PowerWalker


UPS VI-750/R1U 750 VA PowerWalker


UPS AT-UPS3000RT/2-RACK 3000 VA EAST


UPS AT-UPS3000RT/3-RACK 3000 VA EAST


UPS VI-1500/R1U 1500 VA PowerWalker

180.90 EUR
180.90 EUR

184.03 EUR
184.03 EUR

217.70 EUR
217.70 EUR

243.70 EUR
243.70 EUR

131.67 EUR
131.67 EUR

433.38 EUR
433.38 EUR

548.84 EUR
548.84 EUR

574.44 EUR
574.44 EUR

290.49 EUR
290.49 EUR

407.14 EUR
407.14 EUR

407.14 EUR
407.14 EUR

306.02 EUR
306.02 EUR

744.21 EUR
744.21 EUR

659.58 EUR
659.58 EUR

442.22 EUR
442.22 EUR

357.19 EUR
357.19 EUR

444.49 EUR
444.49 EUR

861.33 EUR
861.33 EUR

460.25 EUR
460.25 EUR

470.88 EUR
470.88 EUR

793.68 EUR
793.68 EUR

898.93 EUR
898.93 EUR

221.78 EUR
221.78 EUR

286.33 EUR
286.33 EUR

861.33 EUR
861.33 EUR

861.33 EUR
861.33 EUR

537.16 EUR
537.16 EUR

Power adapter type:  ...  ...  ...  Line-interactive  ...  Online  ...  ...  Online  Online  Online  Line-interactive  Online  Online  Online  Line-interactive  Line-interactive  Online  Line-interactive  ...  ...  ...  ...  ...  Online  Online  ...  
Nominal power:  720 W  900 W  1200 W  1200 W  360 W  1800 W  900 W  1350 W  900 W  900 W  900 W  1200 W  1800 W  1800 W  1800 W  1600 W  2400 W  2700 W  2400 W  600 W  1800 W  2700 W  300 W  450 W  2700 W  2700 W  900 W  
Apparent Power:  1200 VA  1500 VA  2000 VA  2000 VA  650 VA  2000 VA  1000 VA  1500 VA  1000 VA  1000 VA  1000 VA  1500 VA  2000 VA  2000 VA  2000 VA  2000 VA  3000 VA  3000 VA  3000 VA  1000 VA  2000 VA  3000 VA  500 VA  750 VA  3000 VA  3000 VA  1500 VA  
Input voltage:  230 V AC ± 25 %  230 V AC ± 25 %  230 V AC ± 25 %  230 V AC ± 25 %  230 V AC ± 25 %  110 V ... 290 V AC  161  ... 276 V AC  161  ... 276 V AC  230 V AC ± 25 %  230 V AC ± 25 %  230 V AC ± 25 %  230 V AC ± 25 %  230 V AC ± 25 %  230 V AC ± 25 %  208  / 220  / 230  / 240 V AC  230 V AC ± 25 %  
  • 70  ... 150 V AC
  • 145  ... 300 V AC  
  • 230 V AC ± 25 %  230 V AC ± 25 %  165  ... 290 V AC  161  ... 276 V AC  161  ... 276 V AC  165  ... 290 V AC  165  ... 290 V AC  230 V AC ± 25 %  230 V AC ± 25 %  165  ... 290 V AC  
    Input frequency:  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  45  ... 65 Hz (auto detection)  50  / 60 Hz ± 5 % at standard mode
    > 40 Hz at generator mode  

    50  / 60 Hz ± 5 % at standard mode
    > 40 Hz at generator mode  

    50  / 60 Hz (auto detection)  
    50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  40  ... 70 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  45  ... 55 Hz  50  / 60 Hz ± 5 % at standard mode
    > 40 Hz at generator mode  

    50  / 60 Hz ± 5 % at standard mode
    > 40 Hz at generator mode  

    45  ... 55 Hz  
    45  ... 55 Hz  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  45  ... 55 Hz  
    Output voltage:  230 V AC ± 10 % (Approximated Sine Wave)  230 V AC ± 10 % (Approximated Sine Wave)  230 V AC ± 10 % (Approximated Sine Wave)  230 V AC ± 10 % (Approximated Sine Wave)  230 V AC ± 10 % (Approximated Sine Wave)  200  / 208  / 220  / 230  / 240 V AC (Pure Sine Wave)  220  / 230  / 240 V AC (Pure Sine Wave)  220  / 230  / 240 V AC (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  230 V AC ± 10 % (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  208  / 220  / 230  / 240 V AC (Pure Sine Wave) ± 1 %  230 V AC ± 10 % (Pure Sine Wave)  
  • 100  / 110  / 115  / 120 V AC ± 5 % (Pure Sine Wave)
  • 200  / 220  / 230  / 240 V AC ± 5 % (Pure Sine Wave)  
  • 230 V AC ± 5 % (Pure Sine Wave)  230 V AC ± 10 % (Pure Sine Wave)  230 V AC (Pure Sine Wave)  220  / 230  / 240 V AC (Pure Sine Wave)  220  / 230  / 240 V AC (Pure Sine Wave)  230 V AC (Pure Sine Wave)  230 V AC (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  230 V AC (Pure Sine Wave)  
    Charging time (recover to 90% capacity):  ...  ≤ 8 hours  ≤ 8 hours  ≤ 8 hours  ...  4 hours  3 hours  4 hours  4 hours  8 hours  4 hours  8 hours  8 hours  3 hours  3 hours  8 hours  ...  8 hours  8 hours  8 hours  3 hours  4 hours  8 hours  8 hours  8 hours  8 hours  8 hours  
    Output frequency:  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  50  / 60 Hz  ...  ...  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  50  / 60 Hz  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  50  / 60 Hz  50  / 60 Hz ± 0.1 Hz (battery mode)  50  / 60 Hz ± 1 %  50  / 60 Hz ± 0.3 Hz  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  50 Hz  ...  ...  50 Hz  50 Hz  50  / 60 Hz  50  / 60 Hz  50 Hz  
    Voltage adjustment:            ...  ± 5 % RMS for whole range of battery voltages  ± 5 % RMS for whole range of battery voltages    ± 1 %  ± 1 %    ± 1 %  ± 1 %        ± 1 %    ± 10 %  ± 5 % RMS for whole range of battery voltages  ± 5 % RMS for whole range of battery voltages  ± 10 %  ± 10 %  ± 1 %  ± 1 %  ± 10 %  
    Frequency adjustment:            ...  ± 0.1 % (battery mode)  ± 0.1 % (battery mode)                          ± 0.1 % (battery mode)  ± 0.1 % (battery mode)            
    Transfer time:  2  ... 7 ms (typical), max. 10 ms  2  ... 7 ms (typical), max. 10 ms  2  ... 7 ms (typical), max. 10 ms  2  ... 7 ms (typical), max. 10 ms  2  ... 7 ms (typical), max. 10 ms  
  • 0 ms On-Line
  • 4 ms (typical), max. 10 ms Bypass  
  • 2  ... 6 ms (max. 10 ms) (13ms at generator mode)  2  ... 6 ms (max. 10 ms) (13ms at generator mode)  4 ms  0 ms  4 ms  ≤ 10 ms  0 ms  4 ms  
  • 0 ms On-Line
  • 4 ms (typical) Bypass  
  • ≤ 10 ms  ≤ 10 ms  0 ms  ≤ 10 ms  max. 4 ms  2  ... 6 ms (max. 10 ms) (13ms at generator mode)  2  ... 6 ms (max. 10 ms) (13ms at generator mode)  max. 4 ms  max. 4 ms  4 ms  4 ms  max. 4 ms  
    Battery:  2 pcs - 12V/7Ah  2 pcs - 12V/8Ah  2 pcs - 12V/9Ah  2 pcs - 12V/9Ah AGM  1 pcs - 12V/7Ah  4 pcs - 12V/9Ah  3  x 12V/7Ah  3  x 12V/9Ah  3  x 12V/9Ah  2  x 12V/9Ah  3  x 12V/9Ah  2  x 12V/9Ah  4  x 12V/9Ah  4  x 12V/9Ah  4  x 12V/9Ah  3  x 12V/9Ah AGM  4  x 12V/9Ah  8  x 12V/9Ah  4  x 12V/9Ah AGM  4  x 6V/7Ah  6  x 12V/7Ah  6  x 12V/9Ah  2  x 6V/7Ah  2  x 6V/9Ah  8  x 12V/9Ah  8  x 12V/9Ah  4  x 6V/9Ah  
    Additional protection:  ...  ...  ...  ...  ...  RJ-45  RJ11, RJ45  RJ11, RJ45  ...  ...  ...  ...  ...  ...  RJ-45  ...  RJ45  ...  ...  ...  RJ11, RJ45  RJ11, RJ45  ...  ...  ...  ...  ...  
    Estimated battery operation time:  
  • 47 minutes @ 100 W,
  • 20 minutes @ 200 W,
  • 12 minutes @ 300 W,
  • 7 minutes @ 500 W  
  • ...  
  • 62 minutes @ 100 W,
  • 31 minutes @ 200 W,
  • 16 minutes @ 300 W,
  • 9.5 minutes @ 500 W  
  • 62 minutes @ 100 W,
  • 31 minutes @ 200 W,
  • 16 minutes @ 300 W,
  • 9.5 minutes @ 500 W,
  • 2.5 minutes @ 800 W,
  • 1 minute @ 1000 W  
  • 15 minutes @ 100 W,
  • 6 minutes @ 200 W,
  • 2 minutes @ 300 W  
  • ≤ 70 minutes - depending on the load
  • 3  ... 5 minutes (at full load)  
  • 4:30 minutes
    (at full load)  

    4 minutes (at full load)  
  • 35 minutes @ 200 W,
  • 16 minutes @ 400 W,
  • 12 minutes @ 500 W,
  • 10 minutes @ 600 W,
  • 7.5 minutes @ 700 W,
  • 6.5 minutes @ 800 W,
  • 5.5 minutes @ 900 W  
  • ...  
  • 35 minutes @ 200 W,
  • 16 minutes @ 400 W,
  • 10 minutes @ 600 W,
  • 6.5 minutes @ 800 W,
  • 5.5 minutes @ 900 W  
  • 41 minutes @ 100 W,
  • 22 minutes @ 200 W,
  • 15 minutes @ 300 W,
  • 9 minutes @ 400 W,
  • 6.5 minutes @ 500 W,
  • 4 minutes @ 600 W,
  • 2 minutes @ 700 W,
  • 2 minutes @ 800 W,
  • 1.5 minutes @ 900 W,
  • 42 s @ 1000 W  
  • ...  
  • 55 minutes @ 200 W,
  • 27 minutes @ 400 W,
  • 12 minutes @ 600 W,
  • 10 minutes @ 800 W,
  • 7 minutes @ 1000 W,
  • 5 minutes @ 1200 W,
  • 2.5 minutes @ 1600 W  
  • ...  
  • 67 minutes @ 100 W,
  • 37 minutes @ 200 W,
  • 27 minutes @ 300 W,
  • 17 minutes @ 400 W,
  • 12 minutes @ 500 W,
  • 10 minutes @ 600 W,
  • 8 minutes @ 700 W,
  • 6.5 minutes @ 800 W,
  • 5 minutes @ 900 W,
  • 4 minutes @ 1000 W,
  • 2.5 minutes @ 1200 W  
  • ...  ...  
  • 92 minutes @ 100 W,
  • 53 minutes @ 200 W,
  • 39 minutes @ 300 W,
  • 25 minutes @ 400 W,
  • 19 minutes @ 500 W,
  • 16 minutes @ 600 W,
  • 13 minutes @ 700 W,
  • 11 minutes @ 800 W,
  • 9.5 minutes @ 900 W,
  • 6 minutes @ 1000 W,
  • 5 minutes @ 1200 W,
  • 3 minutes @ 1600 W,
  • 2 minutes @ 2000 W  
  • 1.5 minutes @ 100% load
  • 11.4 minutes @ 50% load  
  • 4:30 minutes (at full load)  4 minutes (at full load)  
  • 0.8 minutes @ 100% load
  • 10.3 minutes @ 50% load  
  • 0.4 minutes @ 100% load
  • 8.7 minutes @ 50% load  
  • 120 minutes @ 200 W,
  • 60 minutes @ 400 W,
  • 40 minutes @ 600 W,
  • 25 minutes @ 800 W,
  • 20 minutes @ 1000 W,
  • 12.5 minutes @ 1200 W,
  • 9 minutes @ 1600 W,
  • 7.5 minutes @ 1800 W,
  • 6.5 minutes @ 2000 W,
  • 5 minutes @ 2400 W,
  • 4 minutes @ 2700 W  
  • 120 minutes @ 200 W,
  • 60 minutes @ 400 W,
  • 40 minutes @ 600 W,
  • 25 minutes @ 800 W,
  • 20 minutes @ 1000 W,
  • 12.5 minutes @ 1200 W,
  • 9 minutes @ 1600 W,
  • 7.5 minutes @ 1800 W,
  • 6.5 minutes @ 2000 W,
  • 5 minutes @ 2400 W,
  • 4 minutes @ 2700 W  
  • 3.1 minutes @ 100% load
  • 12.1 minutes @ 50% load  
  • Number of outputs:  2 pcs CEE 7/3 (Schuko)  2 pcs CEE 7/3 (Schuko)  2 pcs CEE 7/3 (Schuko)  3 pcs - 2 x CEE 7/3 (Schuko), 1 x IEC C13  3 pcs IEC C13 ,
    1 pcs CEE 7/3 (Schuko)  
    6 pcs IEC320 C13 10 A  8 pcs  8 pcs  4 pcs IEC-320 C13  2 pcs CEE 7/3 (Schuko)  
  • 1 pcs CEE 7/3 (Schuko),
  • 2 pcs IEC-320 C13  
  • 6 pcs - 3 x CEE 7/3 (Schuko), 3 x IEC C13  2 pcs CEE 7/3 (Schuko)  
  • 1 pcs CEE 7/3 (Schuko),
  • 2 pcs IEC-320 C13  
  • 8 pcs IEC-320 C13  6 pcs - 3 x CEE 7/3 (Schuko), 3 x IEC C13  6 pcs IEC320 C13  2 pcs CEE 7/3 (Schuko)  6 pcs - 3 x CEE 7/3 (Schuko), 3 x IEC C13  4 pcs IEC320 C13 socket  8 pcs  8 pcs  4 pcs IEC320 C13 socket  4 pcs IEC320 C13 socket  
  • 1 pcs CEE 7/3 (Schuko),
  • 2 pcs IEC-320 C13  
  • 6 pcs IEC-320 C13  4 pcs IEC320 C13 socket  
    Management software:  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  GC UPS (Windows 10/11, MAC, Linux - Ubuntu, Debian, Mint)  WinPower (Windows 98/2000/XP/Vista/7/8, MAC, Linux, FreeBSD, Solaris)  WinPower (Windows 98/2000/XP/Vista/7/8, MAC, Linux, FreeBSD, Solaris)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  ...  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  PowerMaster  WinPower (Windows 98/2000/XP/Vista/7/8, MAC, Linux, FreeBSD, Solaris)  WinPower (Windows 98/2000/XP/Vista/7/8, MAC, Linux, FreeBSD, Solaris)  PowerMaster  PowerMaster  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  PowerMaster  
    Protections:  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • Ethernet filter  
  • Glass Fuse
  • Short-circuit
  • Overload
  • Overvoltage - RJ45
  • Ethernet filter
  • Output voltage filtering
  • DC filter to eliminate interferences - EMI/RFI  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • Ethernet filter  
  • Overvoltage
  • Overload
  • Overcharge
  • Ethernet filter  
  • Overload  
  • Overload protection  
  • Glass Fuse
  • Short-circuit
  • Overload
  • Overcharge protection
  • discharge protection
  • Output voltage filtering
  • DC filter to eliminate interferences - EMI/RFI
  • EPO (Emergency power off) switch  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch  
  • Glass Fuse
  • Short-circuit
  • Overload
  • Overvoltage - RJ45
  • Ethernet filter
  • Output voltage filtering
  • DC filter to eliminate interferences - EMI/RFI  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Short-circuit
  • Overload
  • Overvoltage - RJ45
  • Ethernet filter
  • Output voltage filtering
  • DC filter to eliminate interferences - EMI/RFI  
  • Glass Fuse
  • Overload
  • Short-circuit
  • Discharge
  • Overcharge
  • Temperature
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Short-circuit
  • Overload
  • Overvoltage - RJ45
  • Ethernet filter
  • Output voltage filtering
  • DC filter to eliminate interferences - EMI/RFI  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch  
  • Overload protection  
  • Overload protection  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch  
  • Operation state indication:  
  • LCD display: in/out voltage level, in frequency, battery capacity, load, alarm,
  • Sound signaling  
  • LCD display: in/out voltage level, in frequency, battery capacity, load, alarm,
  • Sound signaling  
  • LCD display: in/out voltage level, in frequency, battery capacity, load, alarm,
  • Sound signaling  
  • LCD display: in/out voltage level, in frequency, battery capacity, load, alarm,
  • Sound signaling  
  • LCD display: in/out voltage level, in frequency, battery capacity, load, alarm,
  • Sound signaling  
  • Large, readable LCD display with backlight : Voltage, Current frequency, Work load, Battery status, Battery charging, Temperature, Fan status,
  • LED indicators displaying the device's operating status : Operation modes - On-Line / Battery / Bypass, Error,
  • Sound signaling  
  • ...  ...  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • LED diodes,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator, LED diodes,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator, LED diodes,
  • Sound signaling  
  • Large, readable LCD display with backlight : Voltage, Current frequency, Work load, Battery charge level, Temperature, Fan status,
  • LED indicators displaying the device's operating status : Operation modes - On-Line / Battery / Bypass, Error,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator, LED diodes,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level
  • Sound signaling - with Mute function  
  • ...  ...  
  • LCD display: operation mode, battery charging level, in/out voltage level
  • Sound signaling - with Mute function  
  • LCD display: operation mode, battery charging level, in/out voltage level
  • Sound signaling - with Mute function  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level
  • Sound signaling - with Mute function  
  • Main features:  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • self test feature
  • USB interface  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • self test feature
  • USB interface  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • self test feature
  • USB interface  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • The device works with power supply adapters having Active Power Factor Correction (APFC)
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • self test feature
  • 2 x RJ-45 - Input / Output
  • Port USB 2.0 - Access from PC  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • self test feature
  • USB interface  
  • On-Line double conversion technology
  • High efficiency mode (Bypass)
  • "Cold Start" function
  • Remote management - GC UPS application ( Display of operating parameters, schedule, e-mail personal messaging, local access )
  • USB/RS-232 communication port
  • Relay output
  • SNMP - Option
  • USB A / USB B cable included + Power supply cable  
  • Auto restart while AC is recovering
  • GreenPower UPSTM Technology
  • EPO (Emergency power off) function
  • Automatic Voltage Regulator (AVR)
  • UPS auto diagnostic system
  • Short-time charging
  • USB/RS-232 communication port
  • LCD, audio messages
  • Alarms indication on LCD: blue, red, blinking red based on UPS status
  • 4 x ICE C13 programmable outlets
  • Battery charging at power-off mode
  • "Cold Start" function
  • Energy Saving function (possibility to deactivate from software)  
  • Auto restart while AC is recovering
  • GreenPower UPSTM Technology
  • EPO (Emergency power off) function
  • Automatic Voltage Regulator (AVR)
  • UPS auto diagnostic system
  • Smart battery charging to extend battery lifetime
  • USB/RS-232 communication port
  • LCD, audio messages
  • Alarms indication on LCD: blue, red, blinking red based on UPS status
  • 4 x ICE C13 programmable outlets
  • Battery charging at power-off mode
  • "Cold Start" function
  • Energy Saving function (possibility to deactivate from software)  
  • Auto restart while AC is recovering
  • The device has a rotating display
  • Excellent microprocessor control guarantees high reliability
  • COLD START function for manual switch to the battery power supply
  • Automatic Voltage Regulator (AVR)
  • Battery charge and maintenance control
  • Port RS-232 - Access from PC
  • Remote management - UPSmart application (included)
  • Built-in EMI, RFI filter
  • Battery replacement during operation (Hot-swap)
  • Network card slot
  • Can be mounted in a Rack 19" cabinet
  • The device works with power supply adapters having Active Power Factor Correction (APFC)  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • The device has a rotating display
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Battery replacement during operation (Hot-swap)
  • The device works with power supply adapters having Active Power Factor Correction (APFC)
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • Excellent microprocessor control guarantees high reliability
  • COLD START function for manual switch to the battery power supply
  • Automatic Voltage Regulator (AVR)
  • Battery charge and maintenance control
  • 2 x RJ45 - Input / Output
  • Port USB 2.0 - Access from PC
  • Remote management - UPSmart application (included)
  • Optical - sound signaling
  • Built-in EMI, RFI filter
  • Network card slot
  • Can be mounted in a Rack 19" cabinet
  • The device works with power supply adapters having Active Power Factor Correction (APFC)  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • On-Line double conversion technology
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Remote management - UPSmart application included
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port
  • SNMP - Option  
  • Auto restart while AC is recovering
  • Excellent microprocessor control guarantees high reliability
  • COLD START function for manual switch to the battery power supply
  • Automatic Voltage Regulator (AVR)
  • Battery charge and maintenance control
  • 2 x RJ45 - Input / Output
  • Port USB 2.0 - Access from PC
  • Remote management - UPSmart application (included)
  • Optical - sound signaling
  • Built-in EMI, RFI filter
  • Network card slot
  • Can be mounted in a Rack 19" cabinet
  • The device works with power supply adapters having Active Power Factor Correction (APFC)  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Remote management
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • Automatic battery charging in OFF mode
  • Port USB - Access from PC
  • SNMP - Option
  • Power-saving mode (selectable in the menu)  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • Excellent microprocessor control guarantees high reliability
  • COLD START function for manual switch to the battery power supply
  • Automatic Voltage Regulator (AVR)
  • Battery charge and maintenance control
  • 2 x RJ45 - Input / Output
  • Port USB 2.0 - Access from PC
  • Remote management - UPSmart application (included)
  • Optical - sound signaling
  • Built-in EMI, RFI filter
  • Network card slot
  • Can be mounted in a Rack 19" cabinet
  • The device works with power supply adapters having Active Power Factor Correction (APFC)  
  • Auto restart while AC is recovering
  • "Cold Start" function
  • Expansion slot
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • GreenPower UPSTM Technology
  • EPO (Emergency power off) function
  • Automatic Voltage Regulator (AVR)
  • UPS auto diagnostic system
  • Smart battery charging to extend battery lifetime
  • Intelligent cooler system control to reduce the noise level
  • USB/RS-232 communication port
  • LCD, audio messages
  • Alarms indication on LCD: blue, red, blinking red based on UPS status
  • 4 x ICE C13 programmable outlets
  • Battery charging at power-off mode
  • "Cold Start" function
  • Energy Saving function (possibility to deactivate from software)  
  • Auto restart while AC is recovering
  • GreenPower UPSTM Technology
  • EPO (Emergency power off) function
  • Automatic Voltage Regulator (AVR)
  • UPS auto diagnostic system
  • Smart battery charging to extend battery lifetime
  • Intelligent cooler system control to reduce the noise level
  • USB/RS-232 communication port
  • LCD, audio messages
  • Alarms indication on LCD: blue, red, blinking red based on UPS status
  • 4 x ICE C13 programmable outlets
  • Battery charging at power-off mode
  • "Cold Start" function
  • Energy Saving function (possibility to deactivate from software)  
  • Auto restart while AC is recovering
  • "Cold Start" function
  • Expansion slot
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • "Cold Start" function
  • Expansion slot
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • "Cold Start" function
  • Expansion slot
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Application:  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • medium-sized enterprise
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • medium-sized enterprise
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • medium-sized enterprise
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • medium-sized enterprise
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • medium-sized enterprise
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Housing type:  Rack 19"  Rack 19"  Rack 19"  Rack 19"  Rack 19", 2U  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  RACK  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  RACK  RACK  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  RACK  
    Operation temp. / Relative humidity:  0 °C ... 40 °C / 0  ... 90 %  0 °C ... 40 °C / 0  ... 90 %  0 °C ... 40 °C / 0  ... 90 %  0 °C ... 40 °C / 20  ... 90 %  0 °C ... 40 °C / 0  ... 90 %  0 °C ... 40 °C / 20  ... 90 %  0 °C ... 40 °C / 20  ~ 90 % (non-condensing)  0 °C ... 40 °C / 20  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 95 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 95 % (non-condensing)  5 °C ... 40 °C / ≤ 93 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  5 °C ... 40 °C / ≤ 93 % (non-condensing)  5 °C ... 40 °C ≤ 93 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  5 °C ... 40 °C / ≤ 93 % (non-condensing)  0 °C ... 40 °C / 0  ... 90 % (non-condensing)  0 °C ... 40 °C / 20  ~ 90 % (non-condensing)  0 °C ... 40 °C / 20  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ... 90 % (non-condensing)  0 °C ... 40 °C / 0  ... 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ... 90 % (non-condensing)  
    Weight:  13 kg  13.3 kg  14.8 kg  15.0 kg  7.86 kg  21.2 kg  16.2 kg  17.98 kg  11.4 kg  13.32 kg  14.3 kg  17.1 kg  22 kg  23.4 kg  18.1 kg  21 kg  26.2 kg  32 kg  26.4 kg  14.33 kg  28.1 kg  30.4 kg  7.76 kg  8.81 kg  38.4 kg  38.4 kg  16.31 kg  
    Dimensions:  440  x 310  x 90 mm RACK 19", 3U  440  x 310  x 132 mm, RACK 19", 3U  440  x 310  x 132 mm, RACK 19", 3U  
  • 440  x 308  x 132 mm, RACK 19", 3U
  • 485  x 345  x 132 mm (with bracket)  
  • 483  x 345  x 88 mm  440  x 87  x 552 mm ; RACK 19", 2U  438  x 436  x 86.5 mm  438  x 436  x 86.5 mm  440  x 88  x 320 mm ; RACK 19", 2U  440  x 88  x 478 mm ; RACK 19", 2U  440  x 88  x 430 mm ; RACK 19", 2U  440  x 132  x 410 mm ; RACK 19", 3U  440  x 88  x 658 mm ; RACK 19", 2U  440  x 88  x 658 mm ; RACK 19", 2U  440  x 88  x 658 mm ; RACK 19", 2U  440  x 132  x 410 mm ; RACK 19", 3U  440  x 133  x 405 mm ; RACK 19", 3U  2 pcs : 440  x 85  x 468 mm RACK 19", 2U  440  x 132  x 410 mm ; RACK 19", 3U  435  x 400  x 44 mm ; RACK 19", 1U  438  x 608  x 86.5 mm  438  x 608  x 86.5 mm  435  x 235  x 44 mm ; RACK 19", 1U  435  x 235  x 44 mm ; RACK 19", 1U  2 pcs : 440  x 85  x 468 mm RACK 19", 2U  2 pcs : 440  x 85  x 468 mm RACK 19", 2U  435  x 400  x 44 mm ; RACK 19", 1U  
    Manufacturer / Brand:  EAST  EAST  EAST  EAST  EAST  Green Cell  ...  ...  EAST  EAST  EAST  EAST  EAST  EAST  EAST  EAST  EAST  EAST  EAST  PowerWalker  ...  ...  PowerWalker  PowerWalker  EAST  EAST  PowerWalker  
    Guarantee:  2 years  2 years  2 years  2 years  2 years  2 years ( 12 months - battery )  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years