Top Power Supply  Relay Modules
Compare category Description:Sort:type | price | price a A A

Relay Modules

2R-D7
PTZ control: RS-485 / UART TTL ; Protocol: Modbus RTU ; Transmission speed: 4800 / 9600 / 19200 b/s ; Number of relay outputs: 2 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
Net: 112.30 NOK  Gross: 112.30 NOK
PK1-12-PST
The PK1-12-PST module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: Screw mounting with spacers, ;
Net: 110.00 NOK  Gross: 110.00 NOK
AWZ-513
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 0.5 A, 2 A ;
Net: 106.74 NOK  Gross: 106.74 NOK
KMC-20-11
Device type: Contactor - NO/NC, One-phase ; Nominal load current: 20 A @ AC7A / AC1, 7 A @ AC7B ; Rated load voltage: 230 V AC ; Number of NO/NC contacts: 1 / 1 ; Category of use: AC1, AC7A, AC7B ; Connectors type: screw terminals ; Housing: DIN, TH-35 rail mounting ;
Net: 100.84 NOK  Gross: 100.84 NOK
NEW
KMC-20-20
Device type: Contactor - NO, One-phase ; Nominal load current: 20 A @ AC7A / AC1, 7 A @ AC7B ; Rated load voltage: 230 V AC ; Number of NO/NC contacts: 2 / 0 ; Category of use: AC1, AC7A, AC7B ; Connectors type: screw terminals ; Housing: DIN, TH-35 rail mounting ;
Net: 100.84 NOK  Gross: 100.84 NOK
NEW
PK1-12-ZPC
Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max) @ 30 V DC / 50 V AC ; Output: 1 x NO/NC ; Main features: Time settings range 1. Range : 2 s ... 60 s, 2. Range : 10 s ... 10 minutes ;
Net: 95.81 NOK  Gross: 95.81 NOK
AWZ-511
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max) 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 95.51 NOK  Gross: 95.51 NOK
AWZ-517
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 20 ... 32 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x REL-C/NO/NC ; Main features: 5/20mm delayed fuse 6.3 A ;
Net: 92.70 NOK  Gross: 92.70 NOK
AWZ-514
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
Net: 87.33 NOK  Gross: 87.33 NOK
PK1-24-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 84.83 NOK  Gross: 84.83 NOK
AWZ-529
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 81.46 NOK  Gross: 81.46 NOK
ATLO-DBC5/RELAY
Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 1 x NO/NC ; Wireless: 433 MHz, Range : 15 m (in open area) ;
Net: 79.27 NOK  Gross: 79.27 NOK
PK1-5-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 5 ... 9 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 79.02 NOK  Gross: 79.02 NOK
AWZ-512
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 78.65 NOK  Gross: 78.65 NOK
PK1-12-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 78.17 NOK  Gross: 78.17 NOK
ESP-01-CH340-ESP8266
Compatibility: ESP01, ESP01 and others ; Connectors type: 1 x USB-A plug, 1 x 8x goldpin socket, 8 x goldpin plug ; USB <> TTL Converter: CH340 ; TTL voltage: 3.3 V ; Power output: 3.3 V ; Main features: RESET button ; Power supply: 5 V - from USB port ; Dimensions: 50 x 14 x 12 mm ;
Net: 73.03 NOK  Gross: 73.03 NOK
PK1-24-ZN
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
Net: 70.39 NOK  Gross: 70.39 NOK
PK1-5-ZN
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 5 ... 9 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
Net: 67.28 NOK  Gross: 67.28 NOK
CH340C
Compatibility: ESP01, ESP01S and others ; Connectors type: 1 x USB-A plug, 1 x 8x goldpin socket, 8 x goldpin plug ; USB <> TTL Converter: CH340 ; Output signal level: 3.3 V ; Power output: 3.3 V ; Main features: RESET button ; Power supply: 5 V - from USB port ; Dimensions: 50 x 14 x 12 mm ;
Net: 66.07 NOK  Gross: 66.07 NOK
PK1-12-ZN
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
Net: 64.94 NOK  Gross: 64.94 NOK
UPK-2.1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 2 A @ 30 V AC / DC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 2 A ;
Net: 63.60 NOK  Gross: 63.60 NOK
UPK-2.2
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 1 A @ 30 V AC / DC ; Output: 2 x NO/NC ;
Net: 63.60 NOK  Gross: 63.60 NOK
PK1-5-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 5 ... 9 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Screw mounting with spacers, Protections : Overvoltage, Reverse polarity connection ;
Net: 59.27 NOK  Gross: 59.27 NOK
PK1-12-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Screw mounting with spacers, Protections : Overvoltage, Reverse polarity connection ;
Net: 58.29 NOK  Gross: 58.29 NOK
UPK-1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V AC/DC ; Relay maximal load: 1 A @ 30 V AC/DC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 2 A ;
Net: 57.81 NOK  Gross: 57.81 NOK
AWZ-510
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC, 10 ... 13 V AC ; Relay maximal load: 1 A (max) 30 V DC / 50 V AC ; Output: 1 x NO/NC ;
Net: 50.56 NOK  Gross: 50.56 NOK
P-HF41F-012-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 47.75 NOK  Gross: 47.75 NOK
AWZ-622
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 1 x NO / NC ;
Net: 33.71 NOK  Gross: 33.71 NOK
P-HF41F-005-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 5 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 33.37 NOK  Gross: 33.37 NOK
PK-552
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Current consumption: 111 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
Net: 28.26 NOK  Gross: 28.26 NOK
PK-551
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Current consumption: 65 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 1 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
Net: 17.02 NOK  Gross: 17.02 NOK