It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 5 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Screw mounting with spacers, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 5 ... 9 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 5 ... 9 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 5 ... 9 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Screw mounting with spacers, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Number of relay outputs: 1 ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Wireless: 868 MHz - Bidirectional communication, Range : 1200 m (in open area) ; Main features: LED indication, alarm input - Tamper signaling ;
Number of relay outputs: 1 ; Power supply: 100 ... 240 V AC ; Output load: 13 A (max), 100 V ... 240 V AC ; Main features: Wireless 868 MHz, Energy consumption metering, Load current control, Voltage control, LED indication, ;
Support: HIKVISION AX PRO ; Number of relay outputs: 1 ; Power supply: 100 ... 240 V AC ; Relay maximal load: 13 A (max), 100 V ... 240 V AC ; Output: 230 V AC ; Main features: Wireless 868 MHz, LED indication, ;
Number of relay outputs: 1 ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Main features: Wireless 868 MHz, LED indication, alarm input ;
The PK1-12-PDT module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: DIN, TS-35 rail mounting, ;
The PK1-12-PST module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: Screw mounting with spacers, ;
Number of relay outputs: 2 ; Power supply: 10 ... 16 V DC ; Relay maximal load: max. 2 x 10 A, 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: LED indication, Splash-proof casing ;
Compatibility: ESP01, ESP01S and others ; Connectors type: 1 x USB-A plug, 1 x 8x goldpin socket, 8 x goldpin plug ; USB <> TTL Converter: CH340 ; Output signal level: 3.3 V ; Power output: 3.3 V ; Main features: RESET button ; Power supply: 5 V - from USB port ; Dimensions: 50 x 14 x 12 mm ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO/NC ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Mounting with self-adhesive bases, Screw mounting with spacers Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Protections : Overvoltage, Reverse polarity connection Splash-proof casing ;
The Modbus RD-8 digital output module has 8 transistor outputs; The outputs can take two states: ground potential or power input potential; PTZ control: RS-485 ; Current efficiency: 2 A (single output), 8 A (total) ; Inputs protection;
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 2 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 4 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of inputs: 2 ; Number of relay outputs: 8 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 15 V DC, 21 ... 28 V DC (set by jumpers) ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - T+ / T- input LED indication ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC, 10 ... 13 V AC ; Relay maximal load: 1 A (max) 30 V DC / 50 V AC ; Output: 1 x NO/NC ;
Net:
0.00
EUR
Gross:
0.00
EUR
Weight:
0.00
kg
This site uses cookies. More information about using by us cookie files, their usage and how to modify the acceptance of cookie files, can be found by pressing
link