It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Screw mounting with spacers, Protections : Overvoltage, Reverse polarity connection ;
Number of relay outputs: 1 ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Wireless: 868 MHz - Bidirectional communication, Range : 1200 m (in open area) ; Main features: LED indication, alarm input - Tamper signaling ;
Number of relay outputs: 1 ; Power supply: 7 ... 24 V DC ; Relay maximal load: 5 A (max), 0 V ... 36 V DC ; Output: NO/NC ; Main features: Wireless 868 MHz, LED indication, alarm input ;
The PK1-12-PDT module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: DIN, TS-35 rail mounting, ;
The PK1-12-PST module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: Screw mounting with spacers, ;
Number of relay outputs: 2 ; Power supply: 10 ... 16 V DC ; Relay maximal load: max. 2 x 10 A, 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: LED indication, Splash-proof casing ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO/NC ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Mounting with self-adhesive bases, Screw mounting with spacers Protections : Overvoltage, Reverse polarity connection ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Protections : Overvoltage, Reverse polarity connection Splash-proof casing ;
The Modbus RD-8 digital output module has 8 transistor outputs; The outputs can take two states: ground potential or power input potential; PTZ control: RS-485 ; Current efficiency: 2 A (single output), 8 A (total) ; Inputs protection;
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 2 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of relay outputs: 4 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
PTZ control: Wi-Fi ; Protocol: IEEE 802.11 b/g/n/e/i, Wi-Fi Direct (P2P), TCP, UDP ; Number of inputs: 2 ; Number of relay outputs: 8 pcs ; Relay maximal load: 10 A / 250 V AC, 10 A / 30 V DC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 15 V DC, 21 ... 28 V DC (set by jumpers) ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - T+ / T- input LED indication ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC, 10 ... 13 V AC ; Relay maximal load: 1 A (max) 30 V DC / 50 V AC ; Output: 1 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max) 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 0.5 A, 2 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 5 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 5 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 1 x NO / NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 4 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 15 V DC - no polarization ; Relay maximal load: 2 A / 30 V ; Output: 1 x NO / NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 12 V DC ; Relay maximal load: 2 x 4 A / 48 V DC/AC 2 x 8 A / 250 V DC / 400 V AC ; Output: 4x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V DC ; Current consumption: 65 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 1 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 12 V DC ; Current consumption: 111 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V AC/DC ; Relay maximal load: 1 A @ 30 V AC/DC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 2 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 12 V DC ; Relay maximal load: 2 A @ 30 V AC / DC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 2 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 12 V DC ; Relay maximal load: 1 A @ 30 V AC / DC ; Output: 2 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V ... 230 V AC / DC ; Relay maximal load: 16 A / 250 V AC ; Output: 1 x NO/NC ; Manufacturer / Brand: ORNO ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 3 ; Power supply: 12 V ... 240 V AC / DC ; Relay maximal load: 8 A / 250 V AC ; Output: 3 x NO/NC ; Manufacturer / Brand: ORNO ;
Number of relay outputs: 1 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 10 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: EEPROM non-volatile memory, Time settings range 1 s ... 99 h, ;
Number of relay outputs: 1 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max) @ 30 V DC / 50 V AC ; Output: 1 x NO/NC ; Main features: Time settings range 1. Range : 1 s ... 60 s, 2. Range : 5 s ... 5 minutes ;