Tested cables: RJ45, UTP, FTP, BNC ;
Rated voltage: 400 V / 50 ... 60 Hz ; Maximal current load: 32 A ; Number of poles: 4P ; Grounding: 6h ; Electrical cable: max. 4 x 6 mm² ; Cable terminals: screw terminals ; Plug type: CEE ; "Index of Protection": IP44 / IP54 ; Maximum wire insulation diameter: 20 mm ;
Rated voltage: 400 V / 50 ... 60 Hz ; Maximal current load: 32 A ; Number of poles: 5P ; Grounding: 6h ; Electrical cable: max. 5 x 6 mm² ; Cable terminals: screw terminals ; Plug type: CEE ; "Index of Protection": IP44 / IP54 ; Maximum wire insulation diameter: 22 mm ;
Rated voltage: 400 V / 50 ... 60 Hz ; Maximal current load: 32 A ; Number of poles: 4P ; Grounding: 6h ; Electrical cable: max. 4 x 6 mm² ; Cable terminals: screw terminals ; Plug type: CEE ; "Index of Protection": IP44 / IP54 ; Maximum wire insulation diameter: 20 mm ;
Rated voltage: 400 V / 50 ... 60 Hz ; Maximal current load: 32 A ; Number of poles: 5P ; Grounding: 6h ; Electrical cable: max. 5 x 6 mm² ; Cable terminals: screw terminals ; Plug type: CEE ; "Index of Protection": IP44 / IP54 ;
Application: Indoor ; Pyroelectric sensor: quadruple ; Sensor type: Passive Infra Red (PIR) ; Range: Ø 14 m, Ceiling mounting @ 3 m, ; Sensitivity adjustment ; Protection class (Grade): 2 ; Main features: TAMPER switch indicating open the cover ;
Battery type: Ni-MH : AAA, AA, In the kit : 4 x AA - 1300 mAh ; Typical battery charge time: 8 ... 13 h ; Battery charging current: AAA : 0.080 A, AA : 0.200 A ; LED indicator ;
Battery type: Ni-MH : AAA, AA, In the kit : 4 x AA - 2000 mAh ; Typical battery charge time: 4 ... 9 h ; Battery charging current: AAA : 0.150 A, AA : 0.300 A ; LED indicator ;
Battery type: Ni-MH : AAA, AA, In the kit : 4 x AA - 2000 mAh ; Typical battery charge time: 3 ... 5 h ; Battery charging current: AAA : 0.220 A, AA : 0.500 A ; LED indicator ;
Battery type: 12.8 V : LiFePO4 ; Battery charging current: 12.8 V : 10 A ; LED indicator ;
Battery type: 6 V, 12 V : Lead-Acid, Sealed lead-acid, AGM ; Battery capacity: 6 V : 1.2 Ah ... 14 Ah, 12 V : 1.2 Ah ... 120 Ah ; Battery charging current: 6 V : 1 A, 12 V : 1 A / 4 A ; LCD display ;
Battery type: Ni-MH : AAA, AA - The batteries are charged independently of each other ; Protections: Overheat, Overvoltage, Short-circuit ; LED indicator ;
Rated voltage: 127 ... 230 V AC, 50 / 60 Hz ; Power supply USB: 5 V DC / 2.1 A ; Cable terminals: screw terminals ; Socket type: 2 pcs USB-A ; Color: White (RAL 9003) ;
Rated voltage: 127 ... 230 V AC, 50 / 60 Hz ; Power supply USB: 2 x 5 V DC / 2.1 A ; Cable terminals: screw terminals ; Socket type: 2 pcs USB-A ; Color: Matt black ;
Rated voltage: 127 ... 230 V AC, 50 / 60 Hz ; Power supply USB: 5 V DC / 3.1 A, 9 V DC / 2 A, 12 V DC / 1.5 A ; Cable terminals: screw terminals ; Socket type: 1 pcs USB-C, 1 pcs USB-A ; Color: Matt black ;
Rated voltage: 250 V AC / 50 Hz ; Power supply USB: 5 V DC / 3.4 A (total) ; Cable terminals: screw terminals ; Socket type: 2 pcs USB-A, 1 pcs USB-C ; Color: White ;
Rated voltage: 250 V AC / 50 Hz ; Power supply USB: 5 V DC / 3.4 A (total) ; Cable terminals: screw terminals ; Socket type: 2 pcs USB-A, 1 pcs USB-C ; Color: Black ;
Device type: Circuit Breaker, One-phase ; Rated current: 10 A ; Number of poles: 1 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 10 A ; Number of poles: 3 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 16 A ; Number of poles: 1 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 16 A ; Number of poles: 3 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 20 A ; Number of poles: 1 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 20 A ; Number of poles: 3 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 25 A ; Number of poles: 1 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 25 A ; Number of poles: 3 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 32 A ; Number of poles: 1 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 32 A ; Number of poles: 3 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 40 A ; Number of poles: 1 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 40 A ; Number of poles: 3 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 6 A ; Number of poles: 1 ; Tripping curves: B type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, One-phase ; Rated current: 10 A ; Number of poles: 1 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, One-phase ; Rated current: 16 A ; Number of poles: 1 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 16 A ; Number of poles: 3 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 20 A ; Number of poles: 1 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 20 A ; Number of poles: 3 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 25 A ; Number of poles: 1 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 25 A ; Number of poles: 3 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 32 A ; Number of poles: 1 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;
Device type: Circuit Breaker, Three-phase ; Rated current: 32 A ; Number of poles: 3 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 3 ;
Device type: Circuit Breaker, One-phase ; Rated current: 40 A ; Number of poles: 1 ; Tripping curves: C type ; Breaking capacity: 6000 A ; Connectors type: screw terminals ; Wire gauge: 1 mm² - 25 mm² ; Housing: DIN, TS-35 rail mounting ; Width in 17.5 mm modules: 1 ;