It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V DC, 10 ... 13 V AC ; Relay maximal load: 1 A (max) 30 V DC / 50 V AC ; Output: 1 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max) 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 0.5 A, 2 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 20 ... 32 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x REL-C/NO/NC ; Main features: 5/20mm delayed fuse 6.3 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 5 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 5 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 1 x NO / NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 4 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 10 ... 15 V DC - no polarization ; Relay maximal load: 2 A / 30 V ; Output: 1 x NO / NC ;
The DEE1010B-S2 module allows the expansion of video doorphone features for control of another door or gate; Support: Cooperation with the DAHUA access control systems, Designed for DAHUA video doorphones ; Outputs: 1 x NO / NC, 1 x Exit button, 1 x Reed switch , 2 x RS-485 ; Power supply: 12 V DC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 4 ; Power supply: 12 V DC ; Relay maximal load: 2 x 4 A / 48 V DC/AC 2 x 8 A / 250 V DC / 400 V AC ; Output: 4x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V DC ; Current consumption: 65 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 1 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 12 V DC ; Current consumption: 111 mA, 5 mA - IN input ; Relay maximal load: 10 A (max) @ 28 V DC / 30 V DC / 125 V AC / 250 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - Set with jumpers, LED indication ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V AC/DC ; Relay maximal load: 1 A @ 30 V AC/DC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 2 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 12 V DC ; Relay maximal load: 2 A @ 30 V AC / DC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 2 A ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 2 ; Power supply: 12 V DC ; Relay maximal load: 1 A @ 30 V AC / DC ; Output: 2 x NO/NC ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 230 V AC ; Relay maximal load: 16 A / 250 V AC ; Output: 1 x NO/NC ; Manufacturer / Brand: ORNO ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 24 V DC / AC ; Relay maximal load: 16 A / 250 V AC ; Output: 1 x NO/NC ; Manufacturer / Brand: ORNO ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 1 ; Power supply: 12 V ... 230 V AC / DC ; Relay maximal load: 16 A / 250 V AC ; Output: 1 x NO/NC ; Manufacturer / Brand: ORNO ;
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: 3 ; Power supply: 12 V ... 240 V AC / DC ; Relay maximal load: 8 A / 250 V AC ; Output: 3 x NO/NC ; Manufacturer / Brand: ORNO ;
Support: ABAX/ABAX2 ; Frequency band: 868.0 MHz ... 868.6 MHz ; Radio communication range (at open area): max. 500 m @ ABAX max. 2000 m @ ABAX2 ; Dimensions: 38 x 78 x 16 mm ;
Support: BE WAVE system ; Frequency band: 868.0 MHz ... 868.6 MHz ( ABAX2 ) ; Radio communication range (at open area): < 500 m ; Number of buttons: 5 ; Color: Light gray ; Battery lifetime: < 8 years ; Dimensions: 37 x 66 x 14 mm ;
Support: Wireless alarm systems HIKVISION AX PRO ; Frequency band: 868 MHz ; Radio communication range (at open area): max. 900 m (in open area) ; Dimensions: 63 x 35 x 12 mm ;
Length: 10 m ; Thickness: 0.215 mm ; Width: 50 mm ; Color: Black ; Material: PE + PET ; Main features: Very good adhesion, Reinforcing mesh, Waterproof, UV radiation resistance ;
Length: 10 m ; Thickness: 0.215 mm ; Width: 50 mm ; Color: Silver ; Material: PE + PET ; Main features: Very good adhesion, Reinforcing mesh, Waterproof, UV radiation resistance ;
Length: 10 m ; Width: 50 mm ; Color: Black ; Material: PE ; Main features: Very good adhesion, Waterproof, UV radiation resistance, High and low temperature resistant : -15 °C ... 90 °C ;
Length: 10 m ; Thickness: 0.17 mm ; Width: 48 mm ; Color: Transparent ; Material: PE ; Main features: Very good adhesion, Waterproof, UV radiation resistance, High and low temperature resistant : -10 °C ... 90 °C ;
Length: 1.5 m ; Thickness: 0.66 mm ; Width: 50 mm ; Color: Black ; Material: Rubber ; Main features: Very good adhesion, Waterproof - fix damages under water, UV radiation resistance, High and low temperature resistant : -55 °C ... 93 °C ;
Package: Capsule ; Main features: Nominal drill diameter : 10 mm, Hole / anchorage depth : 80 / 80 mm ;
Net:
0.00
EUR
Gross:
0.00
EUR
Weight:
0.00
kg
This site uses cookies. More information about using by us cookie files, their usage and how to modify the acceptance of cookie files, can be found by pressing
link