The company is closed on: 2024-05-01
Międzynarodowe Święto Pracy
2024-05-03
Święto Konstytucji 3 Maja
Language:Български Český Dansk Deutsch Eesti Ελληνικά English Español Français Italiano Latviešu Lietuvių Magyar Nederlands Polski Português Pусский Română Slovenski Slovenský Suomi Svenska
Currency:1 AUD - 2.5255 PLN 1 CAD - 2.8500 PLN 1 CHF - 4.3110 PLN 1 CZK - 0.1659 PLN 1 DKK - 0.5622 PLN 1 EUR - 4.1948 PLN 1 GBP - 4.8630 PLN 1 HUF - 0.0106 PLN 1 NOK - 0.3581 PLN 1 PLN - 1.0000 PLN 1 SEK - 0.3601 PLN 1 USD - 3.9717 PLN
Menu Recommended article
CCTV system admin default login and password
UPS AT-UPS1500S-LCD 1500 VA EAST
DESCRIPTION The AT-UPS1500S-LCD UPS has been equipped with a number of advanced technologies ensuring active monitoring of the power supply network.
The line-interactive power supplies analyse the voltage, frequency and phase shift angle on a current basis, and filter the voltage transmitted to the connected devices. When a mains failure is detected, the UPS immediately switches to autonomous operation mode and continues to power the equipment using the energy accumulated in internal batteries.
The device works with power supply adapters having Active Power Factor Correction (APFC).
SPECIFICATION
Nominal power :
1200 W
Apparent Power :
1500 VA
Input voltage :
230 V AC ± 25 %
Input frequency :
50 / 60 Hz (auto detection)
Output voltage :
230 V AC ± 10 % (Pure Sine Wave)
Output frequency :
50 / 60 Hz ± 1 %
Voltage adjustment :
Frequency adjustment :
Transfer time :
≤ 10 ms
Charging time (recover to 90% capacity) :
8 hours
Battery :
2 pcs - 12V/9Ah
Estimated battery operation time :
83 minutes @ 100 W, 42 minutes @ 200 W, 20 minutes @ 300 W, 9 minutes @ 500 W, 4 minutes @ 800 W, 1.5 minutes @ 1000 W, 1 minute @ 1200 W
Number of outputs :
3 pcs - 2 x CEE 7/3 (Schuko), 1 x IEC C13
Management software :
UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)
Protections :
Glass Fuse Short-circuit Overload Overvoltage - RJ45 Ethernet filter Overcharge protection discharge protection Output voltage filtering DC filter to eliminate interferences - EMI/RFI
Operation state indication :
LCD display: operation mode, battery charging level, in/out voltage level, overload indicator, LED diodes, Sound signaling
Main features :
Auto restart while AC is recovering Excellent microprocessor control guarantees high reliability COLD START function for manual switch to the battery power supply Automatic Voltage Regulator (AVR) Automatic battery charging in OFF mode self test feature 2 x RJ45 - Input / Output Port USB 2.0 - Access from PC Remote management - UPSmart application (included) Configurable alarm Built-in EMI, RFI filter The device works with power supply adapters having Active Power Factor Correction (APFC)
Application :
network, servers, workstations Surveillance Systems small servers, DVRs, telecommunication equipment, VoIP working hardware, desktop computers, etc.
Housing type :
Tower
Operation temp. / Relative humidity :
5 °C ... 40 °C / ≤ 93 %
Weight :
13.7 kg
Dimensions :
350 x 143 x 215 mm
Manufacturer / Brand :
EAST
Guarantee :
2 years
PRESENTATION FILES PACKAGE Dimensions (L x W x H): 430x240x320 mm Package: Carton Gross Weight: 14.576 kg
COMPONENTS OF WORKING WITH: AT-UPS1500S-LCD
Net: 0.00 NOK
Gross: 0.00 NOK
Weight: 0.00 kg
Warranty of today's shipping if you order in time:
Especially recommended HEX HEAD SCREW SS-M8X20/KL-8.8 Net: 1.20 NOK
HEX HEAD SCREW SS-M8X50/KL-8.8 Net: 2.18 NOK
UPS UT1050EG-FR/UPS 1050 VA CyberPower Net: 1678.78 NOK
SNMP MODULE IDA-ST200P Net: 1704.97 NOK
UPS AT-UPS3000RT/2-RACK 3000 VA EAST Net: 10057.89 NOK
UPS AT-UPS1500R-RACK 1500 VA EAST Net: 2148.92 NOK
SOLAR CHARGE CONTROLLER SCC-30A-PWM-LCD-S2 Net: 93.83 NOK
UPS UT650EG-FR/UPS 650 VA CyberPower Net: 823.29 NOK
SOLAR CHARGE CONTROLLER SCC-30A-MPPT-LCD AZO Digital Net: 1559.73 NOK