Top Power Supply  Relay Modules
Compare category Description:Sort:type | price | price a A A

Relay Modules

P-HF41F-005-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 5 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 1.57 USD  Gross: 1.93 USD
PK-41F-1Z-C2-1/12V
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 7.50 USD  Gross: 9.23 USD
P-HF41F-012-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC (max) ; Output: 1 x NO/NC ;
Net: 2.62 USD  Gross: 3.22 USD
PK1-12-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 4.84 USD  Gross: 5.95 USD
PK1-12-ZN
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
Net: 5.51 USD  Gross: 6.78 USD
PK1-12-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Screw mounting with spacers, Protections : Overvoltage, Reverse polarity connection ;
Net: 5.12 USD  Gross: 6.30 USD
PK1-24-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 4.73 USD  Gross: 5.82 USD
PK1-24-ZN
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
Net: 5.00 USD  Gross: 6.15 USD
PK1-5-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 5 ... 9 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 4.50 USD  Gross: 5.54 USD
PK1-5-ZN
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 5 ... 9 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Mounting with self-adhesive bases, Protections : Overvoltage, Reverse polarity connection ;
Net: 4.18 USD  Gross: 5.14 USD
PK1-5-ZS
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 5 ... 9 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: Screw mounting with spacers, Protections : Overvoltage, Reverse polarity connection ;
Net: 3.85 USD  Gross: 4.74 USD
PK4-24-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 ... 45 V DC ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: NO ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 14.02 USD  Gross: 17.24 USD
GB-104
Number of relay outputs: 1 pcs NC / NO ; Power supply: 230 V AC, Battery backup : ≥ 360 h ; Relay maximal load: 16 A (max) / 250 V AC ;
Net: 8.89 USD  Gross: 10.93 USD
OR-CR-230
Number of relay outputs: 1 pcs NC / NO ; Power supply: 230 V AC ; Relay maximal load: / 250 V AC ;
Net: 12.48 USD  Gross: 15.35 USD
PK1-12-PDT
The PK1-12-PDT module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: DIN, TS-35 rail mounting, ;
Net: 7.75 USD  Gross: 9.53 USD
PK1-12-PST
The PK1-12-PST module consists of a change-over relay and the configuration system setting out control of the relay with high or low state; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: NO/NC ; Main features: Screw mounting with spacers, ;
Net: 7.99 USD  Gross: 9.83 USD
PK2-12-PWT
Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: max. 2 x 10 A, 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: LED indication, Splash-proof casing ;
Net: 14.20 USD  Gross: 17.47 USD
PK2-12-ZWT
Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: max. 2 x 10 A, 30 V DC / 50 V AC ; Output: 2 x NO ; Main features: LED indication, Splash-proof casing ;
Net: 6.88 USD  Gross: 8.46 USD
PK4-12-ZD
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO/NC ; Main features: DIN, TS-35 rail mounting, Protections : Overvoltage, Reverse polarity connection ;
Net: 12.90 USD  Gross: 15.87 USD
PK4-12-ZN/S
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Mounting with self-adhesive bases, Screw mounting with spacers Protections : Overvoltage, Reverse polarity connection ;
Net: 12.85 USD  Gross: 15.81 USD
PK4-12-ZW
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Protections : Overvoltage, Reverse polarity connection Splash-proof casing ;
Net: 10.09 USD  Gross: 12.41 USD
PK4-24-ZN/S
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 24 V DC - Nominal voltage ; Relay maximal load: 5 A (max), 30 V DC / 50 V AC ; Output: 4 x NO ; Main features: Mounting with self-adhesive bases, Screw mounting with spacers Protections : Overvoltage, Reverse polarity connection ;
Net: 12.45 USD  Gross: 15.31 USD
PK8-12-PR/R
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 ... 14.4 V DC ; Relay maximal load: 10 A (max), 30 V DC / 50 V AC ; Output: 8 x NO/NC ; Main features: Mounting with self-adhesive bases Protections : Overvoltage, Reverse polarity connection ;
Net: 20.63 USD  Gross: 25.37 USD
AWZ-508
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 15 V DC, 21 ... 28 V DC (set by jumpers) ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: relay inputs triggering by low or high voltage - T+ / T- input LED indication ;
Net: 8.99 USD  Gross: 11.06 USD
AWZ-510
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V DC, 10 ... 13 V AC ; Relay maximal load: 1 A (max) 30 V DC / 50 V AC ; Output: 1 x NO/NC ;
Net: 5.03 USD  Gross: 6.19 USD
AWZ-511
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max) 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 6.35 USD  Gross: 7.81 USD
AWZ-512
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 1 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 8.38 USD  Gross: 10.31 USD
AWZ-513
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ; Main features: 2 x 5/20mm delayed fuse - 0.5 A, 2 A ;
Net: 5.88 USD  Gross: 7.23 USD
AWZ-514
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
Net: 6.88 USD  Gross: 8.46 USD
AWZ-515
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 4 x NO/NC ; Main features: 2 x Glass Fuse - 0.5 A, 2 A - BELL, SYGNAL output ;
Net: 14.55 USD  Gross: 17.90 USD
AWZ-517
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 20 ... 32 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 1 x REL-C/NO/NC ; Main features: 5/20mm delayed fuse 6.3 A ;
Net: 6.88 USD  Gross: 8.46 USD
AWZ-520
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 5 x NO/NC ;
Net: 10.99 USD  Gross: 13.52 USD
AWZ-529
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 2 A (max), 30 V DC / 50 V AC ; Output: 2 x NO/NC ;
Net: 6.35 USD  Gross: 7.81 USD
AWZ-626
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 10 ... 16 V AC/DC ; Relay maximal load: 6 A (max), 30 V DC / 250 V AC ; Output: 4 x NO/NC ; Main features: 5/20mm delayed fuse - 6.3 A ;
Net: 20.89 USD  Gross: 25.69 USD
MP-1
It can be used to increase maximal load of controller transistor output line and for galvanic isolation between output line and load point; Number of relay outputs: ; Power supply: 12 V DC ; Relay maximal load: 2 x 4 A / 48 V DC/AC 2 x 8 A / 250 V DC / 400 V AC ; Output: 4x NO/NC ;
Net: 19.04 USD  Gross: 23.42 USD
AWZ-516
Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 10 A (max), 30 V DC / 250 V AC ; Output: 1 x NO/NC ; Main features: EEPROM non-volatile memory, Time settings range 1 s ... 99 h, ;
Net: 24.07 USD  Gross: 29.61 USD
AWZ-525
Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max) @ 30 V DC / 50 V AC ; Output: 1 x NO/NC ; Main features: Time settings range 1. Range : 1 s ... 60 s, 2. Range : 5 s ... 5 minutes ;
Net: 10.23 USD  Gross: 12.58 USD
AWZ-526
Number of relay outputs: ; Power supply: 10 ... 14 V DC ; Relay maximal load: 1 A (max) @ 30 V DC / 50 V AC ; Output: 1 x NO/NC ; Main features: Time settings range 1. Range : 1 s ... 60 s, 2. Range : 5 s ... 5 minutes ;
Net: 11.90 USD  Gross: 14.64 USD
PK1-12-PWC
The PK1-12-PWC time relay has 8 operating modes; Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max) @ 30 V DC / 50 V AC ; Output: 1 x NO/NC ; Main features: Time settings range 1. Range : 0.23 s ... 60 s, 2. Range : 2 s ... 10 minutes ;
Net: 13.98 USD  Gross: 17.20 USD
PK1-12-ZPC
Number of relay outputs: ; Power supply: 10 ... 16 V DC ; Relay maximal load: 10 A (max) @ 30 V DC / 50 V AC ; Output: 1 x NO/NC ; Main features: Time settings range 1. Range : 2 s ... 60 s, 2. Range : 10 s ... 10 minutes ;
Net: 7.74 USD  Gross: 9.52 USD