DC voltage measurement: |
600 mV ± (1.0% + 8) @ 0.1 mV , 6 V ± (0.8% + 1) @ 0.001 V , 60 V ± (0.8% + 3) @ 0.01 V , 600 V ± (0.8% + 3) @ 0.1 V , 1000 V ± (1.0% + 3) @ 1 V |
AC voltage measurement: |
6 V ± (1.2% + 5) @ 0.001 V , 60 V ± (1.2% + 5) @ 0.01 V , 600 V ± (1.2% + 5) @ 0.1 V , 750 V ± (1.5% + 5) @ 1 V |
DC current measurement: |
60 A ± (2.5% + 5) @ 0.01 A , 600 A ± (2.5% + 5) @ 0.1 A |
AC current measurement: |
60 A ± (2.5% + 5) @ 0.01 A , 600 A ± (2.5% + 5) @ 0.1 A |
Resistance measurement: |
600 Ω ± (1.2% + 2) @ 0.1 Ω , 6 kΩ ± (1.0% + 2) @ 0.001 kΩ , 60 kΩ ± (1.0% + 2) @ 0.01 kΩ , 600 kΩ ± (1.0% + 2) @ 0.1 kΩ , 6 MΩ ± (1.2% + 2) @ 0.001 MΩ , 60 MΩ ± (1.5% + 5) @ 0.01 MΩ |
Capacitance measurement: |
60 nF ± (4.0% + 25) @ 0.01 nF , 600 nF ± (4.0% + 5) @ 0.1 nF , 6 µF ± (4.0% + 5) @ 0.001 µF , 60 µF ± (4.0% + 5) @ 0.01 µF , 600 µF ± (4.0% + 5) @ 0.1 µF , 6 mF ± (10%) @ 0.001 mF 60 mF @ 0.01 mF |
Inductance measurement: |
|
Frequency measurement: |
10 Hz ... 1 MHz ± (0.1% + 4) @ 0.01 Hz ... 1 kHz |
Temperature measurement: |
°C -40 ... 40 °C ± (3% + 5) @ 1 °C 40 ... 400 °C ± (3% + 5) @ 1 °C 400 ... 1000 °C ± (2% + 5) @ 1 °C, °F -40 ... 104 °F ± (3% + 10) @ 1 °F 104 ... 752 °F ± (3% + 10) @ 1 °F 752 ... 1832 °F ± (2% + 10) @ 0.1 °F |
Automatic change of measuring ranges: |
|
Diode test: |
|
Sound signal of the continuity test: |
|
RS-232: |
|
USB: |
|
Main features: |
True RMS - accurate measurement of the RMS current and voltage for any waveform, NCV - electric field detection function, REL - relative measurement mode, Freezing the highest or lowest measurement, Hold - stopping the meter reading, Flashlight built-in, Large, readable LCD display with backlight, Low battery level alarm, Aesthetic and solid construction, The set includes a practical case |
Power supply: |
3 x 1.5V, type AAA/LR03 battery - included |
Weight: |
0.24 kg |
Dimensions: |
221 x 71 x 41 mm |
Manufacturer / Brand: |
UNI-T |
Guarantee: |
2 years |