Top Other Products  Overvoltage Protections  Safety Multi-Outlet Extension Cords AC 230V
Compare category Description:Sort:type | price | price a A A

AXON-POWER/DIN
OVERVOLTAGE LIMITER AXON-POWER/DIN
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Housing: DIN, TS-35 rail mounting ;
Net: 294.38 SEK  Gross: 362.09 SEK
LE-412223
OVERVOLTAGE LIMITER LE-412223 THREE-PHASE 2 TYPE LEGRAND
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Device type: Overvoltage limiter, Three-phase ; Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 2 type ; Protection level Up L/PE, N/PE: 1.2 kV @ 8/20 µs (T2) ; Nominal discharge current (L/PE, N/PE): 5 kA @ 8/20 µs (T2) ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 971.92 SEK  Gross: 1 195.46 SEK
LE-412253
OVERVOLTAGE LIMITER LE-412253 THREE-PHASE 1+2 TYPE LEGRAND
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Device type: Overvoltage limiter, Three-phase ; Rated voltage: 230 / 400 V AC ; Maximal voltage: 320 V AC ; Class: 1+2 type ; Protection level Up L/PE, N/PE: 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) ; Nominal discharge current (L/PE, N/PE): 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) ; Housing: DIN, TS-35 rail mounting ;
Net: 2 556.62 SEK  Gross: 3 144.64 SEK
LE-412297
PLUG-IN MODULE FOR OVERVOLTAGE LIMITER LE-412297 2 TYPE 20 kA LEGRAND
Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 2 type ; Protection level Up : 1.2 kV @ 8/20 µs (T2) ; Nominal discharge current : 5 kA @ 8/20 µs (T2) ; Maximum stroke current: 20 kA @ 8/20 µs (T2) ;
Net: 272.14 SEK  Gross: 334.73 SEK
LE-412302
PLUG-IN MODULE FOR OVERVOLTAGE LIMITER LE-412302 1+2 TYPE 50 kA LEGRAND
Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 1+2 type ; Protection level Up : 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) ; Nominal discharge current : 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) ; Maximum stroke current: 50 kA @ 8/20 µs (T2) ;
Net: 564.44 SEK  Gross: 694.26 SEK
ACAR-MINI-AGD
MULTI-SOCKET PLUG WITH SURGE PROTECTION ACAR-MINI-AGD
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 2 grounded outlets 10A/250V ;
Net: 117.08 SEK  Gross: 144.01 SEK
ACAR-P7
POWER DISTRIBUTION UNIT ACAR-P7 (5 + 2 OUTLETS)
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V 2 non-grounded outlets 2.5A/250V ;
Net: 189.81 SEK  Gross: 233.47 SEK
LE-049419
POWER DISTRIBUTION UNIT LE-049419 (6 OUTLETS) 1.5 m LEGRAND
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 16 A ; Maximal total load: 3680 W ; Number of outlets: 6 grounded outlets 16A/250V ;
Net: 456.70 SEK  Gross: 561.74 SEK
ACAR-504/WF/RACK
POWER DISTRIBUTION UNIT ACAR-504/WF/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 5 grounded outlets 10A/250V ;
Net: 426.08 SEK  Gross: 524.08 SEK
ACAR-F5/FA/RACK
POWER DISTRIBUTION UNIT ACAR-F5/FA/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ; Housing: RACK 19", 1U ;
Net: 318.12 SEK  Gross: 391.29 SEK
ACAR-S8-DUAL
POWER DISTRIBUTION UNIT ACAR-S8-DUAL
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 8 grounded outlets 10A/250V ;
Net: 281.00 SEK  Gross: 345.63 SEK
ACAR-S8/FA/RACK
POWER DISTRIBUTION UNIT ACAR-S8/FA/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 8 grounded outlets 10A/250V ;
Net: 345.78 SEK  Gross: 425.31 SEK
ACAR-XPROTECTOR
POWER DISTRIBUTION UNIT ACAR-XPROTECTOR
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ;
Net: 237.17 SEK  Gross: 291.72 SEK
AK-SP-05A
POWER DISTRIBUTION UNIT AK-SP-05A AKYGA
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 1.8 m ;
Net: 106.69 SEK  Gross: 131.23 SEK
AK-SP-05B
POWER DISTRIBUTION UNIT AK-SP-05B AKYGA
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 3.0 m ;
Net: 105.02 SEK  Gross: 129.17 SEK
AK-SP-05U
POWER DISTRIBUTION UNIT AK-SP-05U (5 OUTLETS + 2 USB) AKYGA
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V, 2 USB ports 2A/5V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 1.5 m ;
Net: 167.43 SEK  Gross: 205.94 SEK
OR-AE-13144
POWER DISTRIBUTION UNIT OR-AE-13144 (4 OUTLETS + 2 USB) ORNO
Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 4 grounded outlets 10A/250V, 2 USB ports 2.1A/5V ; Length of the cable: 1.4 m ;
Net: 205.14 SEK  Gross: 252.32 SEK
OR-AE-13132
POWER DISTRIBUTION UNIT WITH REMOTE CONTROL OR-AE-13132 (5 OUTLETS) ORNO
Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ; Socket type: CEE 7/5 E type ; Plug type: CEE 7/7 ; Length of the cable: 3 m ; Wireless: 433.92 MHz Operating range in open area : 30 m ; Main features: Remote controlled : Supports max. 5 devices ;
Net: 494.75 SEK  Gross: 608.54 SEK
ACAR-DIGITAL
POWER DISTRIBUTION UNIT ACAR-DIGITAL (5 OUTLETS)
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Protection level: ≤ 1.3 kV ; Nominal load current: 10 A (total) ; Main features: Easily readable LCD with backlight displaying detailed information on system state, Supply voltage measurement, Supply current measurement, Power measurement, Energy measurement ;
Net: 650.13 SEK  Gross: 799.66 SEK
ACAR-ECO-PLUS
POWER DISTRIBUTION UNIT ACAR-ECO-PLUS (6 OUTLETS)
It helps to reduce electricity consumption by auto switch off the stand-by devices; The extension cord is equipped with 3 SLAVE outlets controller by MASTER outlet and 2 separate ones; Maximal load power: 2300 W ; Fuse: 10 A / 250 V ; Protection level: 1.3 kV (L/N) ; Nominal stroke current: 2 kA (L/N) - (8/20µs) ;
Net: 683.77 SEK  Gross: 841.04 SEK
ACAR-SMART
POWER DISTRIBUTION UNIT ACAR-SMART (6 OUTLETS)
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Protection level: ≤ 1.3 kV ; Nominal load current: 10 A (total) ;