Top Other Products  Overvoltage Protections  Safety Multi-Outlet Extension Cords AC 230V
Compare category Description:Sort:type | price | price a A A

AXON-POWER/DIN
OVERVOLTAGE LIMITER AXON-POWER/DIN
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Housing: DIN, TS-35 rail mounting ;
Net: 36.58 CAD  Gross: 44.99 CAD
LE-412223
OVERVOLTAGE LIMITER LE-412223 THREE-PHASE 2 TYPE LEGRAND
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Device type: Overvoltage limiter, Three-phase ; Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 2 type ; Protection level Up L/PE, N/PE: 1.2 kV @ 8/20 µs (T2) ; Nominal discharge current (L/PE, N/PE): 5 kA @ 8/20 µs (T2) ; Connectors type: screw terminals ; Housing: DIN, TS-35 rail mounting ;
Net: 120.77 CAD  Gross: 148.55 CAD
LE-412253
OVERVOLTAGE LIMITER LE-412253 THREE-PHASE 1+2 TYPE LEGRAND
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Device type: Overvoltage limiter, Three-phase ; Rated voltage: 230 / 400 V AC ; Maximal voltage: 320 V AC ; Class: 1+2 type ; Protection level Up L/PE, N/PE: 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) ; Nominal discharge current (L/PE, N/PE): 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) ; Housing: DIN, TS-35 rail mounting ;
Net: 317.69 CAD  Gross: 390.76 CAD
LE-412297
PLUG-IN MODULE FOR OVERVOLTAGE LIMITER LE-412297 2 TYPE 20 kA LEGRAND
Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 2 type ; Protection level Up : 1.2 kV @ 8/20 µs (T2) ; Nominal discharge current : 5 kA @ 8/20 µs (T2) ; Maximum stroke current: 20 kA @ 8/20 µs (T2) ;
Net: 33.82 CAD  Gross: 41.60 CAD
LE-412302
PLUG-IN MODULE FOR OVERVOLTAGE LIMITER LE-412302 1+2 TYPE 50 kA LEGRAND
Rated voltage: 230 / 400 V AC, 50 / 60 Hz ; Class: 1+2 type ; Protection level Up : 1.2 kV @ 10/350 µs (T1) 1.7 kV @ 8/20 µs (T2) ; Nominal discharge current : 8 kA @ 10/350 µs (T1) 20 kA @ 8/20 µs (T2) ; Maximum stroke current: 50 kA @ 8/20 µs (T2) ;
Net: 70.14 CAD  Gross: 86.27 CAD
ACAR-MINI-AGD
MULTI-SOCKET PLUG WITH SURGE PROTECTION ACAR-MINI-AGD
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 2 grounded outlets 10A/250V ;
Net: 14.55 CAD  Gross: 17.90 CAD
ACAR-P7
POWER DISTRIBUTION UNIT ACAR-P7 (5 + 2 OUTLETS)
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V 2 non-grounded outlets 2.5A/250V ;
Net: 23.59 CAD  Gross: 29.02 CAD
LE-049419
POWER DISTRIBUTION UNIT LE-049419 (6 OUTLETS) 1.5 m LEGRAND
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 16 A ; Maximal total load: 3680 W ; Number of outlets: 6 grounded outlets 16A/250V ;
Net: 56.75 CAD  Gross: 69.80 CAD
ACAR-504/WF/RACK
POWER DISTRIBUTION UNIT ACAR-504/WF/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 5 grounded outlets 10A/250V ;
Net: 52.95 CAD  Gross: 65.13 CAD
ACAR-F5/FA/RACK
POWER DISTRIBUTION UNIT ACAR-F5/FA/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ; Housing: RACK 19", 1U ;
Net: 39.53 CAD  Gross: 48.62 CAD
ACAR-S8-DUAL
POWER DISTRIBUTION UNIT ACAR-S8-DUAL
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 8 grounded outlets 10A/250V ;
Net: 34.92 CAD  Gross: 42.95 CAD
ACAR-S8/FA/RACK
POWER DISTRIBUTION UNIT ACAR-S8/FA/RACK
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Number of outlets: 8 grounded outlets 10A/250V ;
Net: 42.97 CAD  Gross: 52.85 CAD
ACAR-XPROTECTOR
POWER DISTRIBUTION UNIT ACAR-XPROTECTOR
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ;
Net: 29.47 CAD  Gross: 36.25 CAD
AK-SP-05A
POWER DISTRIBUTION UNIT AK-SP-05A AKYGA
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 1.8 m ;
Net: 13.26 CAD  Gross: 16.31 CAD
AK-SP-05B
POWER DISTRIBUTION UNIT AK-SP-05B AKYGA
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 3.0 m ;
Net: 13.05 CAD  Gross: 16.05 CAD
AK-SP-05U
POWER DISTRIBUTION UNIT AK-SP-05U (5 OUTLETS + 2 USB) AKYGA
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Total maximal current: 10 A ; Maximal total load: 2500 W ; Number of outlets: 5 grounded outlets 10A/250V, 2 USB ports 2A/5V ; Automatic delayed fuse: 10 A / 250 V ; Length of the cable: 1.5 m ;
Net: 20.81 CAD  Gross: 25.60 CAD
OR-AE-13144
POWER DISTRIBUTION UNIT OR-AE-13144 (4 OUTLETS + 2 USB) ORNO
Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 4 grounded outlets 10A/250V, 2 USB ports 2.1A/5V ; Length of the cable: 1.4 m ;
Net: 25.49 CAD  Gross: 31.35 CAD
OR-AE-13132
POWER DISTRIBUTION UNIT WITH REMOTE CONTROL OR-AE-13132 (5 OUTLETS) ORNO
Total maximal current: 10 A ; Maximal total load: 2300 W ; Number of outlets: 5 grounded outlets 10A/250V ; Socket type: CEE 7/5 E type ; Plug type: CEE 7/7 ; Length of the cable: 3 m ; Wireless: 433.92 MHz Operating range in open area : 30 m ; Main features: Remote controlled : Supports max. 5 devices ;
Net: 61.48 CAD  Gross: 75.62 CAD
ACAR-DIGITAL
POWER DISTRIBUTION UNIT ACAR-DIGITAL (5 OUTLETS)
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Protection level: ≤ 1.3 kV ; Nominal load current: 10 A (total) ; Main features: Easily readable LCD with backlight displaying detailed information on system state, Supply voltage measurement, Supply current measurement, Power measurement, Energy measurement ;
Net: 80.79 CAD  Gross: 99.37 CAD
ACAR-ECO-PLUS
POWER DISTRIBUTION UNIT ACAR-ECO-PLUS (6 OUTLETS)
It helps to reduce electricity consumption by auto switch off the stand-by devices; The extension cord is equipped with 3 SLAVE outlets controller by MASTER outlet and 2 separate ones; Maximal load power: 2300 W ; Fuse: 10 A / 250 V ; Protection level: 1.3 kV (L/N) ; Nominal stroke current: 2 kA (L/N) - (8/20µs) ;
Net: 84.97 CAD  Gross: 104.51 CAD
ACAR-SMART
POWER DISTRIBUTION UNIT ACAR-SMART (6 OUTLETS)
Protection device, protects the devices against lighting discharges or surges in AC 230V power lines; Protection level: ≤ 1.3 kV ; Nominal load current: 10 A (total) ;
Net: 32.13 CAD  Gross: 39.52 CAD