TopProducts Comparison
- Show All
- Show differences
- Back

BUFFERED SWITCHING POWER SUPPLY ADAPTER ZBF-12V/4A


BUFFERED SWITCHING POWER SUPPLY ADAPTER AUPS-40-120-E ATTE


BUFFERED SWITCHING POWER SUPPLY ADAPTER AUPS-70-120-F ATTE


BUFFERED SWITCHING POWER SUPPLY ADAPTER HPSG3-12V5A-D PULSAR


BUFFERED SWITCHING POWER SUPPLY ADAPTER AWZ-637 FOR ACCESS CONTROLLERS DAHUA ASC PULSAR

75.20 EUR
75.20 EUR

79.56 EUR
79.56 EUR

106.42 EUR
106.42 EUR

266.67 EUR
266.67 EUR

180.61 EUR
180.61 EUR

Adapter type:  Switching  Transforming  Transforming  Switching  ...  
Input voltage:  85  ... 264 V AC  190  ... 260 V AC / 50 Hz  190  ... 260 V AC / 50 Hz  200 V ... 240 V AC  230 V AC / 50 Hz  
Output voltage:  
  • 13.8 V DC (mains power mode)
  • 10.5 V ... 13.8 V DC (battery mode)  
  • 10.8  ... 13.8 V DC (buffer operation)  10.2  ... 13.8 V DC (buffer operation)  11.0 V ... 13.8 V (buffer operation)
    10.0 V ... 13.8 V (battery operation)  
    11 V ... 13.8 V DC (buffer operation)  
    Max. output current (total):  5 A  3.5 A (continuous operation)  6 A (continuous operation)  5 A  7 A  
    Battery charging current:  1 A  max. 1.5 A  1 A / 2 A - Jumper on JP1  1.8 A  1 A / 2 A  
    Power:  74.5 W  42 W (continuous operation)  72 W (continuous operation)  69 W  100 W  
    Tamper contact:  ...  ...  ...  ...  50 V DC / 0.5 A  
    Number of outputs:  1   2   1   2   4   
    Protections:  
  • Short-circuit
  • Overload
  • Overvoltage
  • Discharge  
  • Short-circuit
  • Overload
  • Overvoltage
  • Overheat
  • Tamper
  • Reverse polarity connection
  • Discharge
  • Overcharge  
  • Short-circuit
  • Overload
  • Overvoltage
  • Overheat
  • Tamper
  • Reverse polarity connection
  • Discharge
  • Overcharge  
  • Short-circuit
  • Overload
  • Overvoltage
  • Tamper detection - opening the enclosure, removing from mounting surface,
  • Protection against deep discharge of the battery
  • Battery output protection against short circuit and reverse polarity connection  
  • Short-circuit
  • Overload
  • Overvoltage
  • Tamper
  • Reverse polarity connection
  • Discharge  
  • Main features:  ...  
  • LED indication
  • Efficiency : 92 % @ 40 W
  • Technical outputs of the OC type signaling loss of voltage at the PSU output (OUF) and loss of voltage in the 230V mains (ACF)
  • Main cable entries on the back of the enclosure
  • Raster module mounting system (compatible with ATTE devices) - 10.8 mm raster
  • Wall mounting
  • For indoor use
  • "Index of Protection" : IP20  
  • LED indication
  • Efficiency : 90 % @ 70 W
  • Technical outputs of the OC type signaling loss of voltage at the PSU output (OUF) and loss of voltage in the 230V mains (ACF)
  • Main cable entries on the back of the enclosure
  • Raster module mounting system (compatible with ATTE devices) - 10.8 mm raster
  • Wall mounting
  • For indoor use
  • "Index of Protection" : IP20  
  • Efficiency ≤ 86 %
  • START function for manual switch to the battery power supply  
  • Built-in buffered power supply unit with battery and AC mains monitoring
  • Voltage distribution module, 4 circuits protected by 1.5A fuse
  • DIN TS-35 rail, Length : 185 mm
  • LED indication
  • Technical outputs of the relay type and OC
  • Place for battery - 12 V / 17 Ah  
  • Adapter operation control:  
  • AC input voltage presence indication
  • DC output voltage presence indication  
  • AC input voltage presence indication AC
  • DC output voltage presence indication DC
  • Battery charging indication (internal)  
  • AC input voltage presence indication AC
  • DC output voltage presence indication DC
  • Battery charging indication (internal)  
  • EPS FLT output - indicating AC power collapse
  • APS FLT output - No battery or fail battery
  • AC input voltage presence indication AC
  • DC output voltage presence indication DC
  • Battery fault indication
  • Dynamic battery test
  • Battery circuit continuity control
  • Battery voltage control
  • Battery charge and maintenance control  
  • AC input voltage presence indication AC
  • DC output voltage presence indication DC
  • Battery fault indication
  • EPS FLT output - indicating AC power collapse
  • PSU output indicating DC voltage loss or power supply unit failure
  • LoB output - Low battery voltage  
  • Supported norms:  ...  ...  ...  
  • EN 50131-6:2017, Grade 1÷3, Environmental class II
  • EN60839-11-2:2015+AC:2015, Grade 1÷4, Environmental class I
  • "Index of Protection" : IP44  
  • ...  
    Place for battery:  12V/18Ah  12 V / 7 Ah  12 V / 7  ... 18 Ah  12V/40Ah  ...  
    Max. battery dimensions:  260  x 170  x 75 mm  220  x 120  x 80 mm  220  x 170  x 100 mm  300  x 170  x 170 mm  ...  
    Operation temp. / Relative humidity:  ...  ...  ...  -10  ... 40 °C / 20  ... 90 %  ...  
    Operation temp:  ...  -25  ... 50 °C  -25  ... 50 °C  ...  -10 °C ... 40 °C  
    Weight:  1.84 kg  1.4 kg  2.3 kg  8 kg  3.26 kg  
    Dimensions:  288  x 286  x 90 mm  255  x 205  x 95 mm  325  x 305  x 88 mm  405  x 315  x 185 mm  403  x 326  x 100 mm  
    Manufacturer / Brand:  ...  ATTE  ATTE  PULSAR  PULSAR  
    Guarantee:  2 years  3 years  3 years  2 years  2 years