TopProducts Comparison
- Show All
- Show differences
- Back

POWER DISTRIBUTION UNIT ACAR-P7 (5 + 2 OUTLETS)


POWER DISTRIBUTION UNIT LE-049419 (6 OUTLETS) 1.5 m LEGRAND


POWER DISTRIBUTION UNIT ACAR-504/WF/RACK


POWER DISTRIBUTION UNIT ACAR-F5/FA/RACK


POWER DISTRIBUTION UNIT ACAR-S8-DUAL


POWER DISTRIBUTION UNIT ACAR-S8/FA/RACK


POWER DISTRIBUTION UNIT ACAR-XPROTECTOR


POWER DISTRIBUTION UNIT AK-SP-05A AKYGA


POWER DISTRIBUTION UNIT AK-SP-05B AKYGA


POWER DISTRIBUTION UNIT AK-SP-05U (5 OUTLETS + 2 USB) AKYGA


POWER DISTRIBUTION UNIT WITH REMOTE CONTROL OR-AE-13132 (5 OUTLETS) ORNO


POWER DISTRIBUTION UNIT OR-AE-13144 (4 OUTLETS + 2 USB) ORNO


POWER DISTRIBUTION UNIT ACAR-DIGITAL (5 OUTLETS)


POWER DISTRIBUTION UNIT ACAR-ECO-PLUS (6 OUTLETS)


POWER DISTRIBUTION UNIT ACAR-SMART (6 OUTLETS)

16.09 EUR
16.09 EUR

38.72 EUR
38.72 EUR

36.12 EUR
36.12 EUR

26.97 EUR
26.97 EUR

23.82 EUR
23.82 EUR

29.31 EUR
29.31 EUR

20.11 EUR
20.11 EUR

7.94 EUR
7.94 EUR

8.90 EUR
8.90 EUR

14.19 EUR
14.19 EUR

41.94 EUR
41.94 EUR

17.39 EUR
17.39 EUR

55.11 EUR
55.11 EUR

57.96 EUR
57.96 EUR

21.91 EUR
21.91 EUR

Rated current:  ...  ...  10 A (total)  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  
Rated voltage:  230 V AC / 50 Hz  230 V AC / 50 Hz  230 V AC  230 V AC / 50 Hz  230 V AC / 50 Hz  230 V AC / 50 Hz  230 V AC / 50 Hz  230 V AC / 50 Hz  230 V AC / 50 Hz  230 V AC / 50 Hz  230 V AC / 50 Hz  230 V AC / 50 Hz  230 V AC / 50 Hz  ...  230 V AC / 50 Hz  
Nominal voltage:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  230 V AC / 50 Hz  ...  
Total maximal current:  10 A  16 A  ...  ...  ...  ...  10 A  10 A  10 A  10 A  10 A  10 A  ...  ...  ...  
Nominal load current:  ...  ...  ...  max. 10 A (total)  10 A (total)  10 A (total)  ...  ...  ...  ...  ...  ...  10 A (total)  ...  10 A (total)  
Maximal total load:  2300 W  3680 W  ...  2300 W  ...  ...  2300 W  2500 W  2500 W  2500 W  2300 W  2300 W  ...  ...  ...  
Maximal load power:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  2300 W  2300 W  ...  
Fuse:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  10 A / 250 V  ...  
Socket type:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  CEE 7/5 E type  ...  ...  ...  ...  
Plug type:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  CEE 7/7  ...  ...  ...  ...  
Protection level:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ≤ 1.3 kV  1.3 kV (L/N)  ≤ 1.3 kV  
Automatic delayed fuse:  10 A / 250 V    ...  10 A / 250 V      10 A / 250 V  10 A / 250 V  10 A / 250 V  10 A / 250 V  ...  ...    ...  ...  
Leak current:  < 0.5 mA  ...  < 0.5 mA  ...  ...  < 0.5 mA  < 0.5 mA  ...  ...  ...  ...  ...  < 0.5 mA  < 0.5 mA  < 0.5 mA  
DC filter to eliminate interferences:  ...  ...  ...  ...  ...  ...  ...  RFI ≤ 10 dB  RFI ≤ 10 dB  RFI ≤ 10 dB  ...  ...  ...  ...  ...  
Wireless:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  
  • 433.92 MHz
  • Remote control
  • Operating range in open area : 30 m  
  • ...  ...  ...  ...  
    Number of outlets:  5 grounded outlets 10A/250V
    2 non-grounded outlets 2.5A/250V  

    6 grounded outlets 16A/250V - CEE 7/5  
    5 grounded outlets 10A/250V  5 grounded outlets 10A/250V  8 grounded outlets 10A/250V  8 grounded outlets 10A/250V  5 grounded outlets 10A/250V  5 grounded outlets 10A/250V  5 grounded outlets 10A/250V  
  • 5 grounded outlets 10A/250V,
  • 2 USB ports 2A/5V  
  • 5 grounded outlets 10A/250V  
  • 4 grounded outlets 10A/250V,
  • 2 USB ports 2.1A/5V  
  • 5 grounded outlets 16A/250V - (Schuko)  ...  ...  
    Electric shock protection system:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  Ground connectors (pins) connected with ground wire of AC mains  ...  
    Nominal voltage of surge suppressor:  250 V / 50 Hz  275 V / 50 Hz  250 V / 50 Hz  250 V / 50 Hz  250 V / 50 Hz  250 V / 50 Hz  250 V / 50 Hz  250 V / 50 Hz  250 V / 50 Hz  250 V / 50 Hz  ...  ...  ...  250 V  ...  
    Maximum energy absorption:  ...  ...  ...  ...  ...  ...  ...  150 J  150 J  150 J  ...  ...  ...  ...  ...  
    Response time:  < 25 ns  ...  < 25 ns  < 25 ns  < 25 ns  < 25 ns  < 25 ns  < 25 ns  < 25 ns  < 25 ns  ...  ...  < 25 ns  < 25 ns  < 25 ns  
    Protection level of surge suppressor:  ≤ 1.3 kV (L/N)  < 1.5 kV (L/N)  ≤ 1.3 kV (L/N)  ≤ 1.3 kV (L/N)  ≤ 1.3 kV (L/N)  ≤ 1.3 kV (L/N)  ≤ 1.3 kV (L/N)  ...  ...  ...  ...  ...  ...  ...  ...  
    Nominal stroke current:  2 kA (L/N) - (8/20µs)  1.5 kA (L/N) - (8/20µs)  2.5 kA (L/N) - 8/20 µs  2 kA (L/N) - 8/20 µs  2 kA (L/N) - 8/20 µs  2 kA (L/N) - 8/20 µs  1 kA (L/N) - (8/20µs)  ...  ...  ...  ...  ...  2 kA (L/N) - 8/20 µs  2 kA (L/N) - (8/20µs)  2 kA (L/N) 8/20 µs 8/20 µs  
    Number of output outlets:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  
  • 1 MASTER outlet, two-contact with ground contact
  • 3 SLAVE outlets with auto switch off the power supply after switch off the receiver powered from MASTER outlet
  • 2 outlets separate from MASTER outlet  
  • 6   
    Operation temp:  ...  ...  ...  ...  ...  ...  ...  5 °C ... 50 °C  5 °C ... 50 °C  5 °C ... 50 °C  ...  ...  ...  ...  ...  
    Switch:  two-way, with light indication  with light indication  two-way, with light indication  two-way, with light indication  two-way, with light indication  two-way, with light indication  two-way, with light indication  with light indication  with light indication  with light indication      Two-way switch - with light indication  two-way  2 pcs  
    Maximum stroke current:  6.5 kA (L/N) - (8/20µs)  ...  6.5 kA (L/N) - 8/20 µs  10 kA (L/N) - 8/20 µs 2 type  6.5 kA (L/N) - 8/20 µs  6.5 kA (L/N) - 8/20 µs  4.5 kA (L/N) - (8/20µs)  4.5 kA  4.5 kA  4.5 kA  ...  ...  6.5 kA (L/N) - 8/20 µs  6.5 kA (L/N) - (8/20µs)  6.5 kA (L/N)  
    Main features:  ...  
  • Mounting brackets for screwing the device to a flat surface or mounting with fastening ties
  • The body of the device rotates in the range of 180° relative to the mounting brackets
  • Outlets protected with a protection shutter
  • LED indication : Power supply, Overvoltage protection  
  • ...  
  • Current paths shutters
  • DC filter to eliminate interferences : ≤ 35 dB  
  • ...  ...  ...  ...  ...  ...  
  • radio remote controller in the set
  • Remote controlled : Supports max. 5 devices
  • LED indicators displaying the device's operating status
  • Overload protection
  • Current paths shutters
  • Insulation - PVC
  • Wire gauge : 3  x 1.5 mm²
  • "Index of Protection" : IP20  
  • ...  ...  ...  ...  
    Color:  ...  ...  ...  ...  ...  ...  ...  Black  Black  Black  Black  White + Gray  ...  ...  ...  
    Power supply:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  
  • 230 V AC, 50 Hz
  • Remote control : 12V, type A23 battery (included)  
  • ...  ...  ...  ...  
    Main features:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  
  • Easily readable LCD with backlight displaying detailed information on system state,
  • Supply voltage measurement : 80 V ... 250 V @ 50Hz,
  • Supply current measurement : 0.01 A ... 10 A @ 50/60 Hz,
  • Power measurement : 1 W ... 2500 W,
  • Energy measurement : 1 Wh ... 9999 Wh
  • Energy meter reset
  • Setting the alarm after exceeding the power consumption
     
  • ...  ...  
    Length of the cable:  
    1.45 m  

    1.5 m  

    2.7 m  

    2.9 m  

    1.4 m  

    2.9 m  

    1.45 m  

    1.8 m  

    3.0 m  

    1.5 m  

    3 m  

    1.4 m  

    3 m  

    1.45 m  

    1.4 m  
    Housing:  
    Plastic - non-flammable  

    Plastic  

    RACK 19", 1U, Plastic - non-flammable  
    RACK 19", 1U, Plastic - non-flammable  Plastic - non-flammable  RACK 19", 1U, Plastic - non-flammable  Plastic - non-flammable  Plastic (ABS)  Plastic (ABS)  Plastic (ABS)  Plastic  Plastic  Plastic - non-flammable  Plastic - non-flammable  Plastic - non-flammable  
    Weight:  0.44 kg  0.59 kg  0.59 kg  0.93 kg  0.52 kg  0.61 kg  0.51 kg  0.306 kg  0.372 kg  0.318 kg  0.92 kg  0.35 kg  0.65 kg  0.56 kg  0.4 kg  
    Manufacturer / Brand:  ...  LEGRAND  ...  ...  ...  ...  ...  AKYGA  AKYGA  AKYGA  ORNO  ORNO  ...  ...  ...  
    Dimensions:  370  x 65  x 44 mm  423  x 66  x 100 mm  383  x 58  x 55 mm  484  x 54  x 55 mm  445  x 54  x 55 mm  445  x 54  x 55 mm  365  x 65  x 52 mm  305  x 50  x 40 mm  305  x 50  x 40 mm  305  x 50  x 40 mm  390  x 68  x 45 mm  94  x 78  x 78 mm  447  x 57  x 43 mm  447  x 55  x 53 mm  138  x 100  x 63 mm  
    Guarantee:  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years