TopProducts Comparison
- Show All
- Show differences
- Back

AC POWER SUPPLY ADAPTER AWT-468 PULSAR


AC POWER SUPPLY ADAPTER AWT-682 PULSAR


AC POWER SUPPLY ADAPTER TR-40VA/NORATEL SATEL


AC POWER SUPPLY ADAPTER TR-60VA/NORATEL SATEL


BUFFERED SWITCHING POWER SUPPLY ADAPTER APS-1412 SATEL


BUFFERED SWITCHING POWER SUPPLY ADAPTER APS-412 SATEL


BUFFERED SWITCHING POWER SUPPLY ADAPTER APS-612 SATEL


BUFFERED SWITCHING POWER SUPPLY ADAPTER APS-724 SATEL


BUFFERED SWITCHING POWER SUPPLY ADAPTER DING2-12V2A PULSAR


BUFFERED SWITCHING POWER SUPPLY ADAPTER DING2-12V3A PULSAR


BUFFERED SWITCHING POWER SUPPLY ADAPTER DING2-12V5A PULSAR


BUFFERED SWITCHING POWER SUPPLY ADAPTER AWZ-637 FOR ACCESS CONTROLLERS DAHUA ASC PULSAR


SWITCHING ADAPTER PS8D ROGER

21.06 EUR
21.06 EUR

27.52 EUR
27.52 EUR

27.70 EUR
27.70 EUR

33.88 EUR
33.88 EUR

236.63 EUR
236.63 EUR

72.98 EUR
72.98 EUR

265.58 EUR
265.58 EUR

236.63 EUR
236.63 EUR

35.17 EUR
35.17 EUR

38.52 EUR
38.52 EUR

43.79 EUR
43.79 EUR

178.25 EUR
178.25 EUR

51.44 EUR
51.44 EUR

Adapter type:  Transforming  Transforming  Transforming  Transforming  Switching  Switching  Switching  Switching  Switching  Switching  Switching  ...  Switching  
Power voltage:  230 V AC  230 V AC  230  ... 250 V AC  230 V AC  ...  ...  ...  ...  ...  ...  ...  ...  230 V AC  
Input voltage:  ...  ...  ...  ...  230 V AC  230 V AC  230 V AC  230 V AC  200  ... 240 V AC  200  ... 240 V AC  200  ... 240 V AC  230 V AC / 50 Hz  ...  
Output voltage adjustment:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...    
Frequency range:  50 Hz  50 Hz  47  ... 63 Hz  47  ... 63 Hz  ...  ...  ...  ...  ...  ...  ...  ...  ...  
Max. output current (total):  ...  ...  ...  ...  14 A  4 A  6 A  7 A  2.5 A  3.5 A  5 A  7 A  ...  
Output voltage:  
  • 16 V AC,
  • 18 V AC  
  • 18 V AC,
  • 20 V AC  
  • 16 V, 18 V AC  18 V, 20 V AC  12 V DC  12 V DC  12 V DC  24 V DC  13.8 V DC  13.8 V DC  13.8 V DC  11 V ... 13.8 V DC (buffer operation)  13.8 V DC  
    EN norm:  ...  ...  EN61558-2-6  EN61558-2-6  ...  ...  ...  ...  ...  ...  ...  ...  ...  
    Power:  ...  ...  ...  ...  168 W  48 W  72 W  168 W  34.5 W  48.3 W  69 W  100 W  ...  
    Battery charging current:  ...  ...  ...  ...  2 A  0.5 A / 1 A  1.5 A / 3 A  1 A  0.5 A  0.5 A / 1 A (set with the jumper)  1 A / 2 A (set with the jumper)  1 A / 2 A  ...  
    Number of outputs:  ...  ...  ...  ...  ...  ...  ...  ...  1 pcs  1 pcs  1 pcs  4   2 pcs  
    Test voltage between PRI/SEC:  ...  ...  AC 4kV RMS  AC 4kV RMS  ...  ...  ...  ...  ...  ...  ...  ...  ...  
    Efficiency:  ...  ...  ...  ...  ...  ...  ...  ...  ≤ 90 %  ≤ 90 %  ≤ 90 %  ...  ...  
    Maximal load:  
  • 2.2 A @ 16 V AC,
  • 2 A @ 18 V AC  
  • 3.3 A @ 18 V AC,
  • 3 A @ 20 V AC  
  • 2.22 A  3 A  ...  ...  ...  ...  ...  ...  ...  ...  10.8 A  
    Safety class:  ...  ...  II  II  ...  ...  ...  ...  ...  ...  ...  ...  ...  
    Tamper contact:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  50 V DC / 0.5 A  ...  
    Environment class:  II  II  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  
    Isolation class:  ...  ...  B (130°C)  B (130°C)  ...  ...  ...  ...  ...  ...  ...  ...  ...  
    Operation temp. / Relative humidity:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  -10 °C ... 40 °C / 20 % ... 90 %  
    "Index of Protection":  IP43  IP43  IP44  IP43  ...  ...  ...  ...  ...  ...  ...  ...  ...  
    Output power:  40 VA  60 VA  40 VA  60 VA  ...  ...  ...  ...  ...  ...  ...  ...  150 W  
    Application:  
  • to alarm systems powering
  • to automatic systems
  • to low-voltage light installation powering  
  • to alarm systems powering
  • to automatic systems
  • to low-voltage light installation powering  
  • to alarm systems powering
  • to automatic systems
  • to low-voltage light installation powering  
  • to alarm systems powering
  • to automatic systems
  • to low-voltage light installation powering  
  • ...  ...  ...  ...  ...  ...  ...  ...  ...  
    Output:  2 pcs  2 pcs  2 pcs  2 pcs  ...  ...  ...  ...  ...  ...  ...  ...  ...  
    Protections:  ...  ...  ...  ...  
  • Short-circuit
  • Reverse polarity connection
  • Overload
  • Overvoltage  
  • Short-circuit
  • Reverse polarity connection
  • Overload
  • Overvoltage  
  • Short-circuit
  • Reverse polarity connection
  • Overload
  • Overvoltage  
  • Short-circuit
  • Overload
  • Overvoltage
  • Discharge  
  • Short-circuit
  • Overload
  • Overvoltage
  • Overvoltage
  • Battery output protection against short circuit and reverse polarity connection
  • Protection against deep discharge of the battery  
  • Short-circuit
  • Overload
  • Overvoltage
  • Overvoltage
  • Battery output protection against short circuit and reverse polarity connection
  • Protection against deep discharge of the battery  
  • Short-circuit
  • Overload
  • Overvoltage
  • Overvoltage
  • Battery output protection against short circuit and reverse polarity connection
  • Protection against deep discharge of the battery  
  • Short-circuit
  • Overload
  • Overvoltage
  • Tamper
  • Reverse polarity connection
  • Discharge  
  • Overvoltage
  • Overload  
  • Main features:  ...  ...  ...  ...  ...  ...  ...  ...  Grade 2  Grade 2  Grade 2  
  • Built-in buffered power supply unit with battery and AC mains monitoring
  • Voltage distribution module, 4 circuits protected by 1.5A fuse
  • DIN TS-35 rail, Length : 185 mm
  • LED indication
  • Technical outputs of the relay type and OC
  • Place for battery - 12 V / 17 Ah  
  • ...  
    Adapter operation control:  ...  ...  ...  ...  
  • DC output voltage presence indication
  • Battery charging indication
  • AC input voltage presence indication
  • WS output - indicating AC power collapse
  • WB output - Low battery voltage
  • WP output Current overload indication  
  • DC output voltage presence indication
  • Battery charging indication
  • AC input voltage presence indication
  • WS output - indicating AC power collapse
  • WB output - Low battery voltage
  • WP output Current overload indication  
  • DC output voltage presence indication
  • Battery charging indication
  • AC input voltage presence indication
  • WS output - indicating AC power collapse
  • WB output - Low battery voltage
  • WP output Current overload indication  
  • DC output voltage presence indication
  • Battery charging indication
  • AC input voltage presence indication
  • WS output - indicating AC power collapse
  • WB output - Low battery voltage
  • WP output Current overload indication
  • WT output - Signaling of too high temperature of the device  
  • AC input voltage presence indication - AC
  • DC output voltage presence indication - DC
  • Battery fault indication - APS
  • EPS FLT output - indicating AC power collapse, OC type,
  • APS FLT output - Battery fault indication, OC type
  • "Cold Start" function
  • Dynamic battery test
  • Battery circuit continuity control
  • Battery voltage control
  • Battery charge and maintenance control  
  • AC input voltage presence indication - AC
  • DC output voltage presence indication - DC
  • Battery fault indication - APS
  • EPS FLT output - indicating AC power collapse, OC type,
  • APS FLT output - Battery fault indication, OC type
  • "Cold Start" function
  • Dynamic battery test
  • Battery circuit continuity control
  • Battery voltage control
  • Battery charge and maintenance control  
  • AC input voltage presence indication - AC
  • DC output voltage presence indication - DC
  • Battery fault indication - APS
  • EPS FLT output - indicating AC power collapse, OC type,
  • APS FLT output - Battery fault indication, OC type
  • "Cold Start" function
  • Dynamic battery test
  • Battery circuit continuity control
  • Battery voltage control
  • Battery charge and maintenance control  
  • AC input voltage presence indication AC
  • DC output voltage presence indication DC
  • Battery fault indication
  • EPS FLT output - indicating AC power collapse
  • PSU output indicating DC voltage loss or power supply unit failure
  • LoB output - Low battery voltage  
  • ...  
    Housing type:  ...  ...  ...  ...  Plastic, DIN, TS-35 rail mounting  Plastic, DIN, TS-35 rail mounting  Plastic, DIN, TS-35 rail mounting  Aluminum  Plastic, DIN, TS-35 rail mounting  Plastic, DIN, TS-35 rail mounting  Plastic, DIN, TS-35 rail mounting  ...  ...  
    Operation temp:  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  ...  -10 °C ... 40 °C  ...  
    Weight:  1.29 kg  1.29 kg  1.01 kg  1.23 kg  1.18 kg  0.28 kg  0.48 kg  1.17 kg  0.26 kg  0.36 kg  0.4 kg  3.26 kg  0.42 kg  
    Dimensions:  124  x 75  x 65 mm  124  x 75  x 65 mm  124  x 72  x 67 mm  124  x 72  x 67 mm  290  x 100  x 68 mm  79  x 123  x 60 mm  79  x 123  x 90 mm  290  x 100  x 68 mm  106  x 91  x 60 mm, 6 U  176  x 91  x 60 mm, 10 U  176  x 91  x 60 mm, 10 U  403  x 326  x 100 mm  159  x 97  x 30 mm  
    Manufacturer / Brand:  PULSAR  PULSAR  SATEL  SATEL  SATEL  SATEL  SATEL  SATEL  PULSAR  PULSAR  PULSAR  PULSAR  ROGER  
    Guarantee:  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  3 years