- Show All - Show differences - Back | AC POWER SUPPLY ADAPTER AWT-468 PULSAR | AC POWER SUPPLY ADAPTER AWT-682 PULSAR | AC POWER SUPPLY ADAPTER TR-40VA/NORATEL SATEL | AC POWER SUPPLY ADAPTER TR-60VA/NORATEL SATEL | BUFFERED SWITCHING POWER SUPPLY ADAPTER APS-1412 SATEL | BUFFERED SWITCHING POWER SUPPLY ADAPTER APS-412 SATEL | BUFFERED SWITCHING POWER SUPPLY ADAPTER APS-612 SATEL | BUFFERED SWITCHING POWER SUPPLY ADAPTER APS-724 SATEL | BUFFERED SWITCHING POWER SUPPLY ADAPTER DING2-12V2A PULSAR | BUFFERED SWITCHING POWER SUPPLY ADAPTER DING2-12V3A PULSAR | BUFFERED SWITCHING POWER SUPPLY ADAPTER DING2-12V5A PULSAR | BUFFERED SWITCHING POWER SUPPLY ADAPTER AWZ-637 FOR ACCESS CONTROLLERS DAHUA ASC PULSAR | SWITCHING ADAPTER PS8D ROGER |
| | | | | | | | | | | | | |
| 21.06 EUR 21.06 EUR
| 27.52 EUR 27.52 EUR
| 27.70 EUR 27.70 EUR
| 33.88 EUR 33.88 EUR
| 236.63 EUR 236.63 EUR
| 72.98 EUR 72.98 EUR
| 265.58 EUR 265.58 EUR
| 236.63 EUR 236.63 EUR
| 35.17 EUR 35.17 EUR
| 38.52 EUR 38.52 EUR
| 43.79 EUR 43.79 EUR
| 178.25 EUR 178.25 EUR
| 51.44 EUR 51.44 EUR
|
Adapter type: | Transforming | Transforming | Transforming | Transforming | Switching | Switching | Switching | Switching | Switching | Switching | Switching | ... | Switching |
Power voltage: | 230 V AC | 230 V AC | 230 ... 250 V AC | 230 V AC | ... | ... | ... | ... | ... | ... | ... | ... | 230 V AC |
Input voltage: | ... | ... | ... | ... | 230 V AC | 230 V AC | 230 V AC | 230 V AC | 200 ... 240 V AC | 200 ... 240 V AC | 200 ... 240 V AC | 230 V AC / 50 Hz | ... |
Output voltage adjustment: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | |
Frequency range: | 50 Hz | 50 Hz | 47 ... 63 Hz | 47 ... 63 Hz | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Max. output current (total): | ... | ... | ... | ... | 14 A | 4 A | 6 A | 7 A | 2.5 A | 3.5 A | 5 A | 7 A | ... |
Output voltage: | 16 V AC, 18 V AC | 18 V AC, 20 V AC | 16 V, 18 V AC | 18 V, 20 V AC | 12 V DC | 12 V DC | 12 V DC | 24 V DC | 13.8 V DC | 13.8 V DC | 13.8 V DC | 11 V ... 13.8 V DC (buffer operation) | 13.8 V DC |
EN norm: | ... | ... | EN61558-2-6 | EN61558-2-6 | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Power: | ... | ... | ... | ... | 168 W | 48 W | 72 W | 168 W | 34.5 W | 48.3 W | 69 W | 100 W | ... |
Battery charging current: | ... | ... | ... | ... | 2 A | 0.5 A / 1 A | 1.5 A / 3 A | 1 A | 0.5 A | 0.5 A / 1 A (set with the jumper) | 1 A / 2 A (set with the jumper) | 1 A / 2 A | ... |
Number of outputs: | ... | ... | ... | ... | ... | ... | ... | ... | 1 pcs | 1 pcs | 1 pcs | 4 | 2 pcs |
Test voltage between PRI/SEC: | ... | ... | AC 4kV RMS | AC 4kV RMS | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Efficiency: | ... | ... | ... | ... | ... | ... | ... | ... | ≤ 90 % | ≤ 90 % | ≤ 90 % | ... | ... |
Maximal load: | 2.2 A @ 16 V AC, 2 A @ 18 V AC | 3.3 A @ 18 V AC, 3 A @ 20 V AC | 2.22 A | 3 A | ... | ... | ... | ... | ... | ... | ... | ... | 10.8 A |
Safety class: | ... | ... | II | II | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Tamper contact: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | 50 V DC / 0.5 A | ... |
Environment class: | II | II | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Isolation class: | ... | ... | B (130°C) | B (130°C) | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Operation temp. / Relative humidity: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | -10 °C ... 40 °C / 20 % ... 90 % |
"Index of Protection": | IP43 | IP43 | IP44 | IP43 | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Output power: | 40 VA | 60 VA | 40 VA | 60 VA | ... | ... | ... | ... | ... | ... | ... | ... | 150 W |
Application: | to alarm systems powering to automatic systems to low-voltage light installation powering | to alarm systems powering to automatic systems to low-voltage light installation powering | to alarm systems powering to automatic systems to low-voltage light installation powering | to alarm systems powering to automatic systems to low-voltage light installation powering | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Output: | 2 pcs | 2 pcs | 2 pcs | 2 pcs | ... | ... | ... | ... | ... | ... | ... | ... | ... |
Protections: | ... | ... | ... | ... | Short-circuit Reverse polarity connection Overload Overvoltage | Short-circuit Reverse polarity connection Overload Overvoltage | Short-circuit Reverse polarity connection Overload Overvoltage | Short-circuit Overload Overvoltage Discharge | Short-circuit Overload Overvoltage Overvoltage Battery output protection against short circuit and reverse polarity connection Protection against deep discharge of the battery | Short-circuit Overload Overvoltage Overvoltage Battery output protection against short circuit and reverse polarity connection Protection against deep discharge of the battery | Short-circuit Overload Overvoltage Overvoltage Battery output protection against short circuit and reverse polarity connection Protection against deep discharge of the battery | Short-circuit Overload Overvoltage Tamper Reverse polarity connection Discharge | Overvoltage Overload |
Main features: | ... | ... | ... | ... | ... | ... | ... | ... | Grade 2 | Grade 2 | Grade 2 | Built-in buffered power supply unit with battery and AC mains monitoring Voltage distribution module, 4 circuits protected by 1.5A fuse DIN TS-35 rail, Length : 185 mm LED indication Technical outputs of the relay type and OC Place for battery - 12 V / 17 Ah | ... |
Adapter operation control: | ... | ... | ... | ... | DC output voltage presence indication Battery charging indication AC input voltage presence indication WS output - indicating AC power collapse WB output - Low battery voltage WP output Current overload indication | DC output voltage presence indication Battery charging indication AC input voltage presence indication WS output - indicating AC power collapse WB output - Low battery voltage WP output Current overload indication | DC output voltage presence indication Battery charging indication AC input voltage presence indication WS output - indicating AC power collapse WB output - Low battery voltage WP output Current overload indication | DC output voltage presence indication Battery charging indication AC input voltage presence indication WS output - indicating AC power collapse WB output - Low battery voltage WP output Current overload indication WT output - Signaling of too high temperature of the device | AC input voltage presence indication - AC DC output voltage presence indication - DC Battery fault indication - APS EPS FLT output - indicating AC power collapse, OC type, APS FLT output - Battery fault indication, OC type "Cold Start" function Dynamic battery test Battery circuit continuity control Battery voltage control Battery charge and maintenance control | AC input voltage presence indication - AC DC output voltage presence indication - DC Battery fault indication - APS EPS FLT output - indicating AC power collapse, OC type, APS FLT output - Battery fault indication, OC type "Cold Start" function Dynamic battery test Battery circuit continuity control Battery voltage control Battery charge and maintenance control | AC input voltage presence indication - AC DC output voltage presence indication - DC Battery fault indication - APS EPS FLT output - indicating AC power collapse, OC type, APS FLT output - Battery fault indication, OC type "Cold Start" function Dynamic battery test Battery circuit continuity control Battery voltage control Battery charge and maintenance control | AC input voltage presence indication AC DC output voltage presence indication DC Battery fault indication EPS FLT output - indicating AC power collapse PSU output indicating DC voltage loss or power supply unit failure LoB output - Low battery voltage | ... |
Housing type: | ... | ... | ... | ... | Plastic, DIN, TS-35 rail mounting | Plastic, DIN, TS-35 rail mounting | Plastic, DIN, TS-35 rail mounting | Aluminum | Plastic, DIN, TS-35 rail mounting | Plastic, DIN, TS-35 rail mounting | Plastic, DIN, TS-35 rail mounting | ... | ... |
Operation temp: | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | ... | -10 °C ... 40 °C | ... |
Weight: | 1.29 kg | 1.29 kg | 1.01 kg | 1.23 kg | 1.18 kg | 0.28 kg | 0.48 kg | 1.17 kg | 0.26 kg | 0.36 kg | 0.4 kg | 3.26 kg | 0.42 kg |
Dimensions: | 124 x 75 x 65 mm | 124 x 75 x 65 mm | 124 x 72 x 67 mm | 124 x 72 x 67 mm | 290 x 100 x 68 mm | 79 x 123 x 60 mm | 79 x 123 x 90 mm | 290 x 100 x 68 mm | 106 x 91 x 60 mm, 6 U | 176 x 91 x 60 mm, 10 U | 176 x 91 x 60 mm, 10 U | 403 x 326 x 100 mm | 159 x 97 x 30 mm |
Manufacturer / Brand: | PULSAR | PULSAR | SATEL | SATEL | SATEL | SATEL | SATEL | SATEL | PULSAR | PULSAR | PULSAR | PULSAR | ROGER |
Guarantee: | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 3 years |