- Show All - Show differences - Back | FIBER OPTIC CABLE GJXH-2/2000M | FIBER OPTIC CABLE GJXH-2/500M | FIBER OPTIC CABLE GYFXTH-4/2000M | FIBER OPTIC CABLE GYFXTH-4/500M | FIBER OPTIC CABLE ULT-2SM-IN | FIBER OPTIC CABLE ULT-4SM-UNI | FIBER OPTIC CABLE ULT-FC.E-2SM | FIBER OPTIC CABLE GYFXTH-8/2000M | FIBER OPTIC CABLE ULT-12SM-UNI | FIBER OPTIC CABLE ULT-8SM-UNI | FIBER OPTIC CABLE ULT-8MM-UNI |
| | | | | | | | | | | |
| 209.78 EUR 209.78 EUR
| 64.46 EUR 64.46 EUR
| 678.94 EUR 678.94 EUR
| 198.34 EUR 198.34 EUR
| 0.13 EUR 0.13 EUR
| 0.48 EUR 0.48 EUR
| 0.18 EUR 0.18 EUR
| 800.99 EUR 800.99 EUR
| 0.70 EUR 0.70 EUR
| 0.52 EUR 0.52 EUR
| 1.16 EUR 1.16 EUR
|
Fiber type: | Single-mode, ITU-T G.657A1, SUMITOMO | Single-mode, ITU-T G.657A1, SUMITOMO | Single-mode, ITU-T G.652.D, U-DQ(ZN)BH | Single-mode, ITU-T G.652.D, U-DQ(ZN)BH | Single-mode, ITU-T G.657A1, SUMITOMO | Single-mode, ITU-T G.652.D, U-DQ(ZN)BH | Single-mode, G.657A2, 9/125 µm, CORNING | Single-mode, ITU-T G.652.D, U-DQ(ZN)BH | Single-mode, ITU-T G.652.D, U-DQ(ZN)BH | Single-mode, ITU-T G.652.D, U-DQ(ZN)BH | Multi-mode, OM3 |
Number of fibers: | 2 pcs | 2 pcs | 4 pcs | 4 pcs | 2 pcs | 4 pcs | 2 pcs | 8 pcs | 12 pcs | 8 pcs | 8 pcs |
Cable dimensions: | 3 x 2 mm | 3 x 2 mm | ... | ... | 3 x 2 mm | ... | ... | ... | ... | ... | ... |
Cable diameter: | ... | ... | 5.8 mm | 5.8 mm | ... | 5.5 mm | 3 mm | 5.5 mm | 5.5 mm | 5.5 mm | 6 mm |
Cable weight: | 9 kg / 1000 m | 9 kg / 1000 m | ... | ... | 9 kg / 1000 m | ... | 8.5 kg / 1000 m | ... | ... | ... | 45 kg / 1000 m |
Length: | It is sold in 2000 m spools | It is sold in 2000 m spools | It is sold in 2000 m spools | It is sold in 500 m spools | It is sold in max. 1000 m spools | ... | ... | It is sold in 2000 m spools | ... | ... | ... |
Fiber insertion loss: | < 0.35 dB/km for 1310 nm < 0.2 dB/km for 1550 nm | < 0.35 dB/km for 1310 nm < 0.2 dB/km for 1550 nm | ... | ... | < 0.35 dB/km for 1310 nm < 0.2 dB/km for 1550 nm | ... | < 0.36 dB/km for 1310 nm < 0.22 dB/km for 1550 nm | ... | ... | ... | ... |
Buffer diameter: | 250 µm | 250 µm | 250 µm | 250 µm | 250 µm | 250 µm | 250 µm | 250 µm | 250 µm | 250 µm | 250 µm |
Maximum pulling force: | ... | ... | 2000 N (dynamic) | 2000 N (dynamic) | ... | 2000 N (dynamic) | ... | 2000 N (dynamic) | 2000 N (dynamic) | 2000 N (dynamic) | 2000 N - (dynamic) |
Crush resistance: | ... | ... | ... | ... | ... | ... | 500 N / 100 mm | ... | ... | ... | 1000 N |
Minimal bend radius: | 30 mm | 30 mm | 116 mm (during installation) | 116 mm (during installation) | 30 mm | 116 mm (during installation) | 20 x outer diameter (during installation) 10 x outer diameter (after installation) | 116 mm (during installation) | 116 mm (during installation) | 116 mm (during installation) | 60 mm |
Main features: | FRP rods embedded in the coating increasing the mechanical strength of the cable The rectangular cross-section of the coating allows the cable to be bent only in one plane Pulling force ≤ 80 N | FRP rods embedded in the coating increasing the mechanical strength of the cable The rectangular cross-section of the coating allows the cable to be bent only in one plane Pulling force ≤ 80 N | rodent protected the LSZH (or LSOH) jacket - zero halogen, flame retardant and low smoke gel-filled central tube reinforced by aramid yarn ripcord making it easier to cut the outer sheath of the cable | rodent protected the LSZH (or LSOH) jacket - zero halogen, flame retardant and low smoke gel-filled central tube reinforced by aramid yarn ripcord making it easier to cut the outer sheath of the cable | FRP rods embedded in the coating increasing the mechanical strength of the cable The rectangular cross-section of the coating allows the cable to be bent only in one plane Pulling force ≤ 80 N | rodent protected the LSZH (or LSOH) jacket - zero halogen, flame retardant and low smoke gel-filled central tube reinforced by aramid yarn | Very convenient to install the LSZH (or LSOH) jacket - zero halogen, flame retardant and low smoke Due to the reinforcement of aramid fibers, the cable has a high resistance to tension: 800 N Water resistance - 3m water column for 24h Class CPR: Eca | rodent protected the LSZH (or LSOH) jacket - zero halogen, flame retardant and low smoke gel-filled central tube reinforced by aramid yarn ripcord making it easier to cut the outer sheath of the cable | rodent protected the LSZH (or LSOH) jacket - zero halogen, flame retardant and low smoke gel-filled central tube reinforced by aramid yarn | rodent protected the LSZH (or LSOH) jacket - zero halogen, flame retardant and low smoke gel-filled central tube reinforced by aramid yarn | rodent protected the LSZH (or LSOH) jacket - zero halogen, flame retardant and low smoke gel-filled central tube reinforced by aramid yarn UV radiation resistance Class CPR: Eca |
Application: | The main purpose of the GJXH-2/2000M cable are indoor installations Due to its construction and the fiber used, the cable is ideal for FTTH, FTTB networks, server rooms, office and home networks Low weight, small dimensions and very small minimum bending radius allow to successfully use the cable in cable trays | The main purpose of the GJXH-2/500M cable are indoor installations Due to its construction and the fiber used, the cable is ideal for FTTH, FTTB networks, server rooms, office and home networks Low weight, small dimensions and very small minimum bending radius allow to successfully use the cable in cable trays | due to the small size and flexibility, the cables are ideal for installation in cable ducts it is used in modern FTTH and FTTB systems, in server rooms, between buildings installations universal fiber optic cables intended for horizontal connections in buildings and outside buildings in secondary sewage system | due to the small size and flexibility, the cables are ideal for installation in cable ducts it is used in modern FTTH and FTTB systems, in server rooms, between buildings installations universal fiber optic cables intended for horizontal connections in buildings and outside buildings in secondary sewage system | The main purpose of the ULT-2SM-IN cable are indoor installations Due to its construction and the fiber used, the cable is ideal for FTTH, FTTB networks, server rooms, office and home networks Low weight, small dimensions and very small minimum bending radius allow to successfully use the cable in cable trays | due to the small size and flexibility, the cables are ideal for installation in cable ducts it is used in modern FTTH and FTTB systems, in server rooms, between buildings installations universal fiber optic cables intended for horizontal connections in buildings and outside buildings in secondary sewage system | due to the small size and flexibility, the cables are ideal for installation in cable ducts it is used in modern FTTH and FTTB systems, in server rooms, between buildings installations universal fiber optic cables intended for horizontal connections in buildings and outside buildings in secondary sewage system | due to the small size and flexibility, the cables are ideal for installation in cable ducts it is used in modern FTTH and FTTB systems, in server rooms, between buildings installations universal fiber optic cables intended for horizontal connections in buildings and outside buildings in secondary sewage system | due to the small size and flexibility, the cables are ideal for installation in cable ducts it is used in modern FTTH and FTTB systems, in server rooms, between buildings installations universal fiber optic cables intended for horizontal connections in buildings and outside buildings in secondary sewage system | due to the small size and flexibility, the cables are ideal for installation in cable ducts it is used in modern FTTH and FTTB systems, in server rooms, between buildings installations universal fiber optic cables intended for horizontal connections in buildings and outside buildings in secondary sewage system | due to the small size and flexibility, the cables are ideal for installation in cable ducts it is used in modern FTTH and FTTB systems, in server rooms, between buildings installations universal fiber optic cables intended for horizontal connections in buildings and outside buildings in secondary sewage system |
Operation temp: | -30 °C ... 70 °C | -30 °C ... 70 °C | -40 °C ... 60 °C | -40 °C ... 60 °C | -30 °C ... 70 °C | -40 °C ... 60 °C | -40 °C ... 60 °C | -40 °C ... 60 °C | -40 °C ... 60 °C | -40 °C ... 60 °C | -20 °C ... 70 °C |
Installation temperature: | -20 °C ... 60 °C | -20 °C ... 60 °C | -5 °C ... 70 °C | -5 °C ... 70 °C | -20 °C ... 60 °C | -5 °C ... 70 °C | -10 °C ... 60 °C | -5 °C ... 70 °C | -5 °C ... 70 °C | -5 °C ... 70 °C | -20 °C ... 70 °C |
Supported norms: | EN 50267-2-2 EN 50268-2 ISO 4892/2 | EN 50267-2-2 EN 50268-2 ISO 4892/2 | ... | ... | EN 50267-2-2 EN 50268-2 ISO 4892/2 | ... | EN 50267-2-2 EN 50268-2 ISO 4892/2 | ... | ... | ... | ... |
Guarantee: | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years | 2 years |