TopProducts Comparison
- Show All
- Show differences
- Back

UPS AT-UPS2000R-RACK 2000 VA EAST


UPS AT-UPS2000R/2-RACK 2000 VA EAST


UPS UPS14 RACK 2000 VA Green Cell


UPS VI-1500-RT/LCD 1500 VA


UPS AT-UPS1500S-RT-RACK 1500 VA EAST


UPS AT-UPS2000RT-RACK 2000 VA EAST


UPS AT-UPS2000RT/2-RACK 2000 VA EAST


UPS AT-UPS2000RT/3-RACK 2000 VA EAST


UPS AT-UPS2000S-RT-RACK 2000 VA EAST


UPS AT-UPS3000R-RACK 3000 VA EAST


UPS AT-UPS3000RT-RACK 3000 VA EAST


UPS AT-UPS3000S-RT-RACK 3000 VA EAST


UPS VI-2000-RT/LCD 2000 VA


UPS VI-3000-RT/LCD 3000 VA


UPS AT-UPS3000RT/2-RACK 3000 VA EAST


UPS AT-UPS3000RT/3-RACK 3000 VA EAST

217.14 EUR
217.14 EUR

243.08 EUR
243.08 EUR

432.28 EUR
432.28 EUR

572.97 EUR
572.97 EUR

305.24 EUR
305.24 EUR

742.31 EUR
742.31 EUR

657.89 EUR
657.89 EUR

441.09 EUR
441.09 EUR

356.28 EUR
356.28 EUR

443.36 EUR
443.36 EUR

859.13 EUR
859.13 EUR

459.07 EUR
459.07 EUR

791.66 EUR
791.66 EUR

896.63 EUR
896.63 EUR

859.13 EUR
859.13 EUR

859.13 EUR
859.13 EUR

Power adapter type:  ...  Line-interactive  Online  ...  Line-interactive  Online  Online  Online  Line-interactive  Line-interactive  Online  Line-interactive  ...  ...  Online  Online  
Nominal power:  1200 W  1200 W  1800 W  1350 W  1200 W  1800 W  1800 W  1800 W  1600 W  2400 W  2700 W  2400 W  1800 W  2700 W  2700 W  2700 W  
Apparent Power:  2000 VA  2000 VA  2000 VA  1500 VA  1500 VA  2000 VA  2000 VA  2000 VA  2000 VA  3000 VA  3000 VA  3000 VA  2000 VA  3000 VA  3000 VA  3000 VA  
Input voltage:  230 V AC ± 25 %  230 V AC ± 25 %  110 V ... 290 V AC  161  ... 276 V AC  230 V AC ± 25 %  230 V AC ± 25 %  230 V AC ± 25 %  208  / 220  / 230  / 240 V AC  230 V AC ± 25 %  
  • 70  ... 150 V AC
  • 145  ... 300 V AC  
  • 230 V AC ± 25 %  230 V AC ± 25 %  161  ... 276 V AC  161  ... 276 V AC  230 V AC ± 25 %  230 V AC ± 25 %  
    Input frequency:  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  45  ... 65 Hz (auto detection)  50  / 60 Hz ± 5 % at standard mode
    > 40 Hz at generator mode  

    50  / 60 Hz (auto detection)  
    50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  40  ... 70 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz (auto detection)  50  / 60 Hz ± 5 % at standard mode
    > 40 Hz at generator mode  

    50  / 60 Hz ± 5 % at standard mode
    > 40 Hz at generator mode  

    50  / 60 Hz (auto detection)  
    50  / 60 Hz (auto detection)  
    Output voltage:  230 V AC ± 10 % (Approximated Sine Wave)  230 V AC ± 10 % (Approximated Sine Wave)  200  / 208  / 220  / 230  / 240 V AC (Pure Sine Wave)  220  / 230  / 240 V AC (Pure Sine Wave)  230 V AC ± 10 % (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  208  / 220  / 230  / 240 V AC (Pure Sine Wave) ± 1 %  230 V AC ± 10 % (Pure Sine Wave)  
  • 100  / 110  / 115  / 120 V AC ± 5 % (Pure Sine Wave)
  • 200  / 220  / 230  / 240 V AC ± 5 % (Pure Sine Wave)  
  • 230 V AC ± 5 % (Pure Sine Wave)  230 V AC ± 10 % (Pure Sine Wave)  220  / 230  / 240 V AC (Pure Sine Wave)  220  / 230  / 240 V AC (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  230 V AC ± 5 % (Pure Sine Wave)  
    Output frequency:  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  50  / 60 Hz  ...  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  50  / 60 Hz  50  / 60 Hz ± 0.1 Hz (battery mode)  50  / 60 Hz ± 1 %  50  / 60 Hz ± 0.3 Hz  50  / 60 Hz ± 1 %  50  / 60 Hz ± 1 %  ...  ...  50  / 60 Hz  50  / 60 Hz  
    Charging time (recover to 90% capacity):  ≤ 8 hours  ≤ 8 hours  4 hours  4 hours  8 hours  8 hours  3 hours  3 hours  8 hours  ...  8 hours  8 hours  3 hours  4 hours  8 hours  8 hours  
    Voltage adjustment:      ...  ± 5 % RMS for whole range of battery voltages    ± 1 %  ± 1 %        ± 1 %    ± 5 % RMS for whole range of battery voltages  ± 5 % RMS for whole range of battery voltages  ± 1 %  ± 1 %  
    Frequency adjustment:      ...  ± 0.1 % (battery mode)                  ± 0.1 % (battery mode)  ± 0.1 % (battery mode)      
    Transfer time:  2  ... 7 ms (typical), max. 10 ms  2  ... 7 ms (typical), max. 10 ms  
  • 0 ms On-Line
  • 4 ms (typical), max. 10 ms Bypass  
  • 2  ... 6 ms (max. 10 ms) (13ms at generator mode)  ≤ 10 ms  0 ms  4 ms  
  • 0 ms On-Line
  • 4 ms (typical) Bypass  
  • ≤ 10 ms  ≤ 10 ms  0 ms  ≤ 10 ms  2  ... 6 ms (max. 10 ms) (13ms at generator mode)  2  ... 6 ms (max. 10 ms) (13ms at generator mode)  4 ms  4 ms  
    Battery:  2 pcs - 12V/9Ah  2 pcs - 12V/9Ah AGM  4 pcs - 12V/9Ah  3  x 12V/9Ah  2  x 12V/9Ah  4  x 12V/9Ah  4  x 12V/9Ah  4  x 12V/9Ah  3  x 12V/9Ah AGM  4  x 12V/9Ah  8  x 12V/9Ah  4  x 12V/9Ah AGM  6  x 12V/7Ah  6  x 12V/9Ah  8  x 12V/9Ah  8  x 12V/9Ah  
    Additional protection:  ...  ...  RJ-45  RJ11, RJ45  ...  ...  ...  RJ-45  ...  RJ45  ...  ...  RJ11, RJ45  RJ11, RJ45  ...  ...  
    Estimated battery operation time:  
  • 62 minutes @ 100 W,
  • 31 minutes @ 200 W,
  • 16 minutes @ 300 W,
  • 9.5 minutes @ 500 W  
  • 62 minutes @ 100 W,
  • 31 minutes @ 200 W,
  • 16 minutes @ 300 W,
  • 9.5 minutes @ 500 W,
  • 2.5 minutes @ 800 W,
  • 1 minute @ 1000 W  
  • ≤ 70 minutes - depending on the load
  • 3  ... 5 minutes (at full load)  
  • 4 minutes (at full load)  
  • 41 minutes @ 100 W,
  • 22 minutes @ 200 W,
  • 15 minutes @ 300 W,
  • 9 minutes @ 400 W,
  • 6.5 minutes @ 500 W,
  • 4 minutes @ 600 W,
  • 2 minutes @ 700 W,
  • 2 minutes @ 800 W,
  • 1.5 minutes @ 900 W,
  • 42 s @ 1000 W  
  • ...  
  • 55 minutes @ 200 W,
  • 27 minutes @ 400 W,
  • 12 minutes @ 600 W,
  • 10 minutes @ 800 W,
  • 7 minutes @ 1000 W,
  • 5 minutes @ 1200 W,
  • 2.5 minutes @ 1600 W  
  • ...  
  • 67 minutes @ 100 W,
  • 37 minutes @ 200 W,
  • 27 minutes @ 300 W,
  • 17 minutes @ 400 W,
  • 12 minutes @ 500 W,
  • 10 minutes @ 600 W,
  • 8 minutes @ 700 W,
  • 6.5 minutes @ 800 W,
  • 5 minutes @ 900 W,
  • 4 minutes @ 1000 W,
  • 2.5 minutes @ 1200 W  
  • ...  ...  
  • 92 minutes @ 100 W,
  • 53 minutes @ 200 W,
  • 39 minutes @ 300 W,
  • 25 minutes @ 400 W,
  • 19 minutes @ 500 W,
  • 16 minutes @ 600 W,
  • 13 minutes @ 700 W,
  • 11 minutes @ 800 W,
  • 9.5 minutes @ 900 W,
  • 6 minutes @ 1000 W,
  • 5 minutes @ 1200 W,
  • 3 minutes @ 1600 W,
  • 2 minutes @ 2000 W  
  • 4:30 minutes (at full load)  4 minutes (at full load)  
  • 120 minutes @ 200 W,
  • 60 minutes @ 400 W,
  • 40 minutes @ 600 W,
  • 25 minutes @ 800 W,
  • 20 minutes @ 1000 W,
  • 12.5 minutes @ 1200 W,
  • 9 minutes @ 1600 W,
  • 7.5 minutes @ 1800 W,
  • 6.5 minutes @ 2000 W,
  • 5 minutes @ 2400 W,
  • 4 minutes @ 2700 W  
  • 120 minutes @ 200 W,
  • 60 minutes @ 400 W,
  • 40 minutes @ 600 W,
  • 25 minutes @ 800 W,
  • 20 minutes @ 1000 W,
  • 12.5 minutes @ 1200 W,
  • 9 minutes @ 1600 W,
  • 7.5 minutes @ 1800 W,
  • 6.5 minutes @ 2000 W,
  • 5 minutes @ 2400 W,
  • 4 minutes @ 2700 W  
  • Number of outputs:  2 pcs CEE 7/3 (Schuko)  3 pcs - 2 x CEE 7/3 (Schuko), 1 x IEC C13  6 pcs IEC320 C13 10 A  8 pcs  6 pcs - 3 x CEE 7/3 (Schuko), 3 x IEC C13  2 pcs CEE 7/3 (Schuko)  
  • 1 pcs CEE 7/3 (Schuko),
  • 2 pcs IEC-320 C13  
  • 8 pcs IEC-320 C13  6 pcs - 3 x CEE 7/3 (Schuko), 3 x IEC C13  6 pcs IEC320 C13  2 pcs CEE 7/3 (Schuko)  6 pcs - 3 x CEE 7/3 (Schuko), 3 x IEC C13  8 pcs  8 pcs  
  • 1 pcs CEE 7/3 (Schuko),
  • 2 pcs IEC-320 C13  
  • 6 pcs IEC-320 C13  
    Management software:  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  GC UPS (Windows 10/11, MAC, Linux - Ubuntu, Debian, Mint)  WinPower (Windows 98/2000/XP/Vista/7/8, MAC, Linux, FreeBSD, Solaris)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  ...  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  WinPower (Windows 98/2000/XP/Vista/7/8, MAC, Linux, FreeBSD, Solaris)  WinPower (Windows 98/2000/XP/Vista/7/8, MAC, Linux, FreeBSD, Solaris)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  UPSmart (Windows 95/98/2000/XP/Vista/7/8/10, Linux)  
    Protections:  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • Ethernet filter  
  • Glass Fuse
  • Short-circuit
  • Overload
  • Overvoltage - RJ45
  • Ethernet filter
  • Output voltage filtering
  • DC filter to eliminate interferences - EMI/RFI  
  • Overvoltage
  • Overload
  • Overcharge
  • Ethernet filter  
  • Overload protection  
  • Glass Fuse
  • Short-circuit
  • Overload
  • Overvoltage - RJ45
  • Ethernet filter
  • Output voltage filtering
  • DC filter to eliminate interferences - EMI/RFI  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Short-circuit
  • Overload
  • Overvoltage - RJ45
  • Ethernet filter
  • Output voltage filtering
  • DC filter to eliminate interferences - EMI/RFI  
  • Glass Fuse
  • Overload
  • Short-circuit
  • Discharge
  • Overcharge
  • Temperature
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Short-circuit
  • Overload
  • Overvoltage - RJ45
  • Ethernet filter
  • Output voltage filtering
  • DC filter to eliminate interferences - EMI/RFI  
  • Overload protection  
  • Overload protection  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Glass Fuse
  • Overvoltage
  • Overload protection
  • EPO (Emergency power off) switch
  • Ethernet filter  
  • Operation state indication:  
  • LCD display: in/out voltage level, in frequency, battery capacity, load, alarm,
  • Sound signaling  
  • LCD display: in/out voltage level, in frequency, battery capacity, load, alarm,
  • Sound signaling  
  • Large, readable LCD display with backlight : Voltage, Current frequency, Work load, Battery status, Battery charging, Temperature, Fan status,
  • LED indicators displaying the device's operating status : Operation modes - On-Line / Battery / Bypass, Error,
  • Sound signaling  
  • ...  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator, LED diodes,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator, LED diodes,
  • Sound signaling  
  • Large, readable LCD display with backlight : Voltage, Current frequency, Work load, Battery charge level, Temperature, Fan status,
  • LED indicators displaying the device's operating status : Operation modes - On-Line / Battery / Bypass, Error,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator, LED diodes,
  • Sound signaling  
  • ...  ...  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • LCD display: operation mode, battery charging level, in/out voltage level, overload indicator,
  • Sound signaling  
  • Main features:  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • self test feature
  • USB interface  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • The device works with power supply adapters having Active Power Factor Correction (APFC)
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • self test feature
  • 2 x RJ-45 - Input / Output
  • Port USB 2.0 - Access from PC  
  • On-Line double conversion technology
  • High efficiency mode (Bypass)
  • "Cold Start" function
  • Remote management - GC UPS application ( Display of operating parameters, schedule, e-mail personal messaging, local access )
  • USB/RS-232 communication port
  • Relay output
  • SNMP - Option
  • USB A / USB B cable included + Power supply cable  
  • Auto restart while AC is recovering
  • GreenPower UPSTM Technology
  • EPO (Emergency power off) function
  • Automatic Voltage Regulator (AVR)
  • UPS auto diagnostic system
  • Smart battery charging to extend battery lifetime
  • USB/RS-232 communication port
  • LCD, audio messages
  • Alarms indication on LCD: blue, red, blinking red based on UPS status
  • 4 x ICE C13 programmable outlets
  • Battery charging at power-off mode
  • "Cold Start" function
  • Energy Saving function (possibility to deactivate from software)  
  • Auto restart while AC is recovering
  • Excellent microprocessor control guarantees high reliability
  • COLD START function for manual switch to the battery power supply
  • Automatic Voltage Regulator (AVR)
  • Battery charge and maintenance control
  • 2 x RJ45 - Input / Output
  • Port USB 2.0 - Access from PC
  • Remote management - UPSmart application (included)
  • Optical - sound signaling
  • Built-in EMI, RFI filter
  • Network card slot
  • Can be mounted in a Rack 19" cabinet
  • The device works with power supply adapters having Active Power Factor Correction (APFC)  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • On-Line double conversion technology
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Remote management - UPSmart application included
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port
  • SNMP - Option  
  • Auto restart while AC is recovering
  • Excellent microprocessor control guarantees high reliability
  • COLD START function for manual switch to the battery power supply
  • Automatic Voltage Regulator (AVR)
  • Battery charge and maintenance control
  • 2 x RJ45 - Input / Output
  • Port USB 2.0 - Access from PC
  • Remote management - UPSmart application (included)
  • Optical - sound signaling
  • Built-in EMI, RFI filter
  • Network card slot
  • Can be mounted in a Rack 19" cabinet
  • The device works with power supply adapters having Active Power Factor Correction (APFC)  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Remote management
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • Automatic battery charging in OFF mode
  • Port USB - Access from PC
  • SNMP - Option
  • Power-saving mode (selectable in the menu)  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • Excellent microprocessor control guarantees high reliability
  • COLD START function for manual switch to the battery power supply
  • Automatic Voltage Regulator (AVR)
  • Battery charge and maintenance control
  • 2 x RJ45 - Input / Output
  • Port USB 2.0 - Access from PC
  • Remote management - UPSmart application (included)
  • Optical - sound signaling
  • Built-in EMI, RFI filter
  • Network card slot
  • Can be mounted in a Rack 19" cabinet
  • The device works with power supply adapters having Active Power Factor Correction (APFC)  
  • Auto restart while AC is recovering
  • GreenPower UPSTM Technology
  • EPO (Emergency power off) function
  • Automatic Voltage Regulator (AVR)
  • UPS auto diagnostic system
  • Smart battery charging to extend battery lifetime
  • Intelligent cooler system control to reduce the noise level
  • USB/RS-232 communication port
  • LCD, audio messages
  • Alarms indication on LCD: blue, red, blinking red based on UPS status
  • 4 x ICE C13 programmable outlets
  • Battery charging at power-off mode
  • "Cold Start" function
  • Energy Saving function (possibility to deactivate from software)  
  • Auto restart while AC is recovering
  • GreenPower UPSTM Technology
  • EPO (Emergency power off) function
  • Automatic Voltage Regulator (AVR)
  • UPS auto diagnostic system
  • Smart battery charging to extend battery lifetime
  • Intelligent cooler system control to reduce the noise level
  • USB/RS-232 communication port
  • LCD, audio messages
  • Alarms indication on LCD: blue, red, blinking red based on UPS status
  • 4 x ICE C13 programmable outlets
  • Battery charging at power-off mode
  • "Cold Start" function
  • Energy Saving function (possibility to deactivate from software)  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Auto restart while AC is recovering
  • Automatic Voltage Regulator (AVR)
  • "Cold Start" function
  • Compatible with power generators
  • Remote management - UPSmart application included
  • Built-in EMI, RFI filter
  • Excellent microprocessor control guarantees high reliability
  • UPS auto diagnostic system
  • Battery charge and maintenance control
  • USB/RS-232 communication port  
  • Application:  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • medium-sized enterprise
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • medium-sized enterprise
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • medium-sized enterprise
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • medium-sized enterprise
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Surveillance Systems
  • data storage centers
  • network, servers, workstations
  • Industrial Equipment  
  • Housing type:  Rack 19"  Rack 19"  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  Rack/Tower 2-in-1 Design  
    Operation temp. / Relative humidity:  0 °C ... 40 °C / 0  ... 90 %  0 °C ... 40 °C / 20  ... 90 %  0 °C ... 40 °C / 20  ... 90 %  0 °C ... 40 °C / 20  ~ 90 % (non-condensing)  5 °C ... 40 °C / ≤ 93 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  5 °C ... 40 °C / ≤ 93 % (non-condensing)  5 °C ... 40 °C ≤ 93 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  5 °C ... 40 °C / ≤ 93 % (non-condensing)  0 °C ... 40 °C / 20  ~ 90 % (non-condensing)  0 °C ... 40 °C / 20  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  0 °C ... 40 °C / 0  ~ 90 % (non-condensing)  
    Weight:  14.8 kg  15.0 kg  21.2 kg  17.98 kg  17.1 kg  22 kg  23.4 kg  18.1 kg  21 kg  26.2 kg  32 kg  26.4 kg  28.1 kg  30.4 kg  38.4 kg  38.4 kg  
    Dimensions:  440  x 310  x 132 mm, RACK 19", 3U  
  • 440  x 308  x 132 mm, RACK 19", 3U
  • 485  x 345  x 132 mm (with bracket)  
  • 440  x 87  x 552 mm ; RACK 19", 2U  438  x 436  x 86.5 mm  440  x 132  x 410 mm ; RACK 19", 3U  440  x 88  x 658 mm ; RACK 19", 2U  440  x 88  x 658 mm ; RACK 19", 2U  440  x 88  x 658 mm ; RACK 19", 2U  440  x 132  x 410 mm ; RACK 19", 3U  440  x 133  x 405 mm ; RACK 19", 3U  2 pcs : 440  x 85  x 468 mm RACK 19", 2U  440  x 132  x 410 mm ; RACK 19", 3U  438  x 608  x 86.5 mm  438  x 608  x 86.5 mm  2 pcs : 440  x 85  x 468 mm RACK 19", 2U  2 pcs : 440  x 85  x 468 mm RACK 19", 2U  
    Manufacturer / Brand:  EAST  EAST  Green Cell  ...  EAST  EAST  EAST  EAST  EAST  EAST  EAST  EAST  ...  ...  EAST  EAST  
    Guarantee:  2 years  2 years  2 years ( 12 months - battery )  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years  2 years